4. USE
The machine have been designed, manufactured and
protected to be used to make express coffee and hot
beverages (tea, cappuccino, etc.). Any other use is to
be considered unsuitable and therefore dangerous.
The manufacturer cannot be held respon-
sible for any damage caused to people
or things due to unsuitable, erroneous or
irrational use of the machine.
The operator must always follow the indications
contained in this manual. In the case of a failure or if
the machine is not working properly, switch it off and
do not attempt any direct repair. Refer exclusively
to a service centre.
2.3. Mechanical protective devices
The machine is equipped with the following protective
devices:
complete panelling protection of all the parts
subject to heat and of the steam and hot water
supplier;
cup-warmer plate supplied with a tray to collect
spilt liquids;
work surface provided with grill and tray to collect
spilt liquids;
expansion valve in the hydraulic system and valve
on the boiler to avoid overpressure;
nonreturn valve on the hydraulic system to avoid
flowing back to the main supply.
2.4. Electric safety devices
The safety devices provided are:
12V low tension push buttons an the USB control
key panel;
thermal protection on the pump motor;
gas failure thermocouple and thermocouple ther-
mostat automatically closing gas tap;
safe resistance thermal;
Electronic safety devices.
2.5. Aerial noise
Noise level in the working place does not usually
exceed 70dB(A).
2.6. Vibrations
The machine is supplied with rubber vibration dam-
ping feet. In normal working conditions, the machine
does not produce vibrations harmful to the operator
and the environment.
3. TECHNICAL DATA
3.1. Dimensions and weights
(Fig.5)
You’ll find all the technical data on electric
connection, on the machine identification
label Fig. 1.
Machines provided with gas heating have a standard
connection kit to carry out the following connections
with:
- direct stiff pipe;
- copper and double cone pipe;
- rubber support.
Gas connections must be made in complian-
ce with the safety regulations in force in the
relative country.
2 GROUPS
3 GROUPS
4 GROUPS
A mm
780
1020
1260
B mm
700
940
1180
C mm
540
540
540
D mm
470
470
470
H mm
530
530
530
Boiler capacity in litr.
11
16
22
Machine weight kg
76
94
112
Water inlet
3/8”
3/8”
3/8”
Ømm drainage
14
14
14
Packaging
Volume m
3
0,44
0,55
0,67
Dimensions L x P x H mm
910x670x720
1150x670x720
1390x670x720
Gross weight kg
91
111
134
Summary of Contents for CLASSE 10
Page 4: ......
Page 6: ......
Page 8: ...8 Fig 3 3 18 3 6 MOD S 3 6 15 MOD USB MOD RE 1 8 1 1 1 5 1...
Page 9: ...9 Fig 4 Fig 5 Fig 6 Fig 7 20 16 13 10 9 7 A B D C H 4 3 L o v a t o L 2 3 8 G 1 30 mm...
Page 11: ...11 1 Fig 11 Fig 12 Fig 10 Fig 9...
Page 127: ...127 VS RV RV IL SC SC CL VA MA2 GR GR PV EA P SL EH EF MA1 PA EC ES VR VR Ref Si_61 Mod S RE...
Page 130: ...www rancilio com Cod 46900146 REV AD 05 2012...