background image

13

 

Battery reverse polarity, the controller will not be damaged, will continue 

normal operation after correcting wiring errors. 

 

Light battery polarity protection:

 

the photovoltaic cell polarity reverse, the controller will not be damaged, 

will continue normal operation after correcting wiring errors. 

Products Selection And Technical Specifications

 

Series 

SDI-P series PWM LCD solar charge controller 

Rated charge current

 

50A

 

60A

 

70A

 

80A

 

Model

 

SDI-P50

 

SDI-P60A

 

SDI-P70

 

SDI-80

 

System voltage

 

12V\24V\36V\48V

 

PV max open circuit voltage

 

150V

 

Rated load current

 

50A

 

60A

 

70A

 

80A

 

Direct charge voltage

 

GEL: 14.4V, LEAD ACID: 14.2V, Custom: 9~17V (x12V)

 

Boost charge voltage

 

GEL: 14.8V, LEAD ACID: 14.6V, Custom: 9~17V (x12V)

 

Float charge voltage

 

GEL / LEAD ACID: 13.8V, Custom: 9~17V (x12V)

 

Over-discharge return voltage

 

GEL / LEAD ACID: 12.6V, Custom: 9~17V (x12V)

 

Over-discharge voltage

 

GEL

11.0V

LEAD ACID: 11.1V, Custom: 9~17V (x12V)

 

Loss

 

≤15mA(12V); ≤10mA(24V); ≤8mA(48V)

 

Load dual period control

 

Auto

 

External temperature sensor

 

DS18B20

 

Temperature compensation

 

-5mV/

/2V

 

Communicate interface

 

RS485,MODBUS

 

USB interface

 

5V 1A

 

Dimensions

 

186x107x67mm

 

Terminal Connection

 

2AWG 25mm²

 

Net weight

 

1025g

 

Protection class

 

IP30

 

Summary of Contents for SHLD-60

Page 1: ...8V Max PV Voltage 150V Rated Current 50A 80A Date of Purchase S N Ramsond Corporation World headquarters 4051 Haggerty Rd West Bloomfield MI 48323 Ramsond North America Service Warranty Center 14850 L...

Page 2: ...g term safe and reliable operation within the definition PV and Battery both with against reverse protection All products are equipped with soft start and overload time limit protection adaptation cap...

Page 3: ...or custom Variety parameters can be modified support panel keypad or infrared remote control Support PV Battery Load key parameters display and check Manual Light Control or automatic dual period loa...

Page 4: ...RS485 terminal Connected with computer or other controllers to realize the remote communication 5 The terminal of the temperature sensor Connected with the controller temperature sensor that offered...

Page 5: ...06 mm Distance of installation hole 177 5x60 mm Installation hole 6 5x3 5 mm Install Step a Type Selection Please strictly follow the system application range choose the most appropriate products spec...

Page 6: ...state to adjust it Typically as long as the battery voltage is in the range shown in the following table the controller can correctly recognize the system voltage without manually setting 12V system...

Page 7: ...hich built in SDI P series controller can be soft start and provides a larger starting current to the load especially for the capacitive load equipment such as inverters switching power supplies etc g...

Page 8: ...button to on off the load Note When Controller fails the error icon flashes and an error code display on the LCD screen User can press up or down button to view details Table of Error Code E101 load...

Page 9: ...to mode PV 3 Light control voltage PV 4 Light control delay time minute BAT 5 Battery type BAT 6 System Voltage Note following parameter only for battery type at DIY BAT 7 Over voltage BAT 8 Over disc...

Page 10: ...late the battery voltage to maintain it at the setting value to prevent battery overcharge c Float Charging At this stage the battery nearly full no need more power But the controller will remain very...

Page 11: ...monitor status of the controller Others Additional interfaces optional SDI P series controller configuration USB interface is optional interface which Supports load output capability of USB 5V1A Batt...

Page 12: ...by the controller temperature protection control Overload time limited protection The load current is equal to 1 25 times the rated current with working for 120s load disconnect output 1 5 times for 1...

Page 13: ...12V 24V 36V 48V PV max open circuit voltage 150V Rated load current 50A 60A 70A 80A Direct charge voltage GEL 14 4V LEAD ACID 14 2V Custom 9 17V x12V Boost charge voltage GEL 14 8V LEAD ACID 14 6V Cus...

Page 14: ...essness or negligence if the problem was preventable by proper usage then the warranty is not applicable and Ramsond Corporation must charge a fee for repair services For complete information on warra...

Page 15: ...15 Fax 248 363 7834 Sales Service Email sales ramsond com Technical Support Email tech ramsond com Web www ramsond com Note Dates Time Weather Solar Voltage Solar Amperage Battery Voltage...

Reviews: