TYPICAL TEST PROCEDURES
12. While keyed adjust the generator output as necessary to achieve 12 db SINAD.
13. Subtract the transmitter turned off SINAD from the transmitter turned on SINAD setting
to arrive at the actual dB level of desensitization.
14. Typical readings are usually no more than 1 – 3 dB of measurable desensitization.
TX PASS
TX PASS
RX PASS
RX PASS
FIGURE-2
DESENS TEST SETUP
SET COM3010 TO