PREPARING FOR USE
To prevent health problems the RAMSET SG 125E concrete grinder must be
connected to an industrial vacuum cleaner (connection diameter 36 mm).
Best results are obtained if not too much pressure is exerted on the surface being
ground.
For direct grinding against a wall the front end of the dust cap can be removed by
means of a turnbuckle. This also makes it easier to work on less accessible places.
Caution!
Any other grinding work may only take place with a completely fitted protective
cover.
The start-up limiter ensures the normal starting of the machine.
If permanently overloaded the motor overheats and the machine switches off. In this
case the machine can only be used again after a cooling timed (3-5 minutes).
Changing the cup wheel
First and foremost the removable front of the dust cap must be removed. Then open
the lock and remove the detachable front of the dust cap. The spanner (1) Ø 32 can
now be used to lock the flange between the machine and the cup wheel.
The spanner (2) can be used to loosen the fixing nut. Replacement takes place in
reverse order.
Changing the brush ring
When worn to 5mm the whole brush ring must be changed for a new one. To do this
one loosens the three fixed brush ring fixing screws and the two screws of the front of
the brush ring to remove the brush. The new brush ring is pressed in and one
retightens the five screws. (New brushes have a length of 15 mm.)