8
9) Drain water by pushing the button of the
water filter with cartridge
10) Removal of the connected tool,
the drilling rig and the air hose is
opposite of assembly
Vacuum buffer tank (optional)
The tool could be used with the vacuum buffer tank. Once the power is cut suddenly,
the vacuum buffer tank could keep on providing vacuum for a long period. The vacuum
won’t be cut suddenly and it could prevent from possible danger.
Drain water by loosening the sluicing valve.
MAINTENANCE
Keep tool clean
Periodically blow out all air passages with dry compressed air. All plastic parts should
cleaned with a soft damp cloth. NEVER use solvents to clean plastic parts. They could
possibly dissolve or otherwise damage the material.
Wear safety glasses while using compressed air.
DRAIN OFF WATER AFTER USE ALL THE TIME
Sluicing valve