11
www.ramsetinc.com
RAMSET
R
AM 3
00 U
L
Opening
Pressing this button will cause the gate to open.
Stop
Pressing this button will cause the gate to
stop moving.
Closing
Pressing this button will cause the gate to close.
Reset E.R.D. Board
Push all three pushbuttons for approximately
5 seconds. All three L.E.D.’s should blink.
"Intelligate" Control Board
Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The opening, stop
and closing buttons can be utilized to set limit switches and verify proper system operation when installing or
servicing an operator.
PUSHBUTTON CONTROLS
MASTER - SLAVE INSTALLATION
L.E.D.’s light up when Opening,
Closing or Stopped
Figure 12
Figure 11
Set Dip Switch (C8) "Slave Mode" to ON for
slave operator.
(RH) Right Hand operation requires Dip Switch
(C7) "Left/Right" to be ON.