5. NEVER CARRY THE TOOL WITH YOUR 
FINGER ON, OR DEPRESSING, THE TRIGGER. 

You must remember that the GypFast tool  
operates in a specific sequence . The Safety 
Yoke acts as an operating feature that blocks the 
Trigger from completing the ignition circuit . Should 
you unintentionally depress the Safety Yoke while  
pulling the Trigger as you are carrying the tool . . . 
  it could discharge a fastener . 

6. NEVER OPERATE A TOOL THAT IS  
MALFUNCTIONING. 

If you determine that the 

GypFast tool is not working properly, and the 
problem is more than a simple fastener jam, stop 
using it immediately and refer to the Servicing 
Section of this manual . If the problem cannot be 
corrected with one of the steps covered in the 
Servicing Section, report the problem to your 
supervisor or Ramset Distributor representative . 

Do not attempt to make any additional repairs 
to the GypFast tool.

7. OPERATE THE TOOL ONLY ON THE WORK 
SURFACE.

 The GypFast tool 

should be operated only when  
it is in contact with the work  
surface . Always hold the tool  
firm and perpendicular against 
the surface to be fastened .  

8. NEVER DISABLE OR REMOVE THE SAFETY 
YOKE.

 The GypFast tool is equipped with a 

device called the Safety Yoke . This device helps 
reduce the possibility of accidental operation by 
preventing the tool from operating until it is fully 
depressed on the work surface . The Safety Yoke 
must never be disabled or removed . Do not use 
the GypFast tool if the Safety Yoke is not working 
properly . 

9. DO NOT LOAD FASTENERS WITH  
THE TRIGGER OR SAFETY YOKE DEPRESSED. 

When loading fasteners into the GypFast tool,  
you must avoid pulling the Trigger or while having  
the Safety Yoke depressed . When the tool is 
placed on a bench or other surface, the Safety 
Yoke might be depressed . When you are loading 
fasteners, you could accidentally pull the Trigger 
by grasping the Handle to steady the tool . These 
two actions will cause the GypFast tool to operate, 
discharging a fastener . 

10. FASTENER REMOVAL OR CLEARING 
JAMS. 

With the GypFast tool pointed away from 

you and others, slightly push the Release Lever 
to open the Magazine door . Tip the tool Nose 
up slightly, and the fasteners will slide out . If you 
have a jammed fastener, or other problem with the 
operation of your GypFast tool, you should stop 
attempting to use the tool and refer immediately to 
the Servicing Section of the manual . 

11. NEVER ATTEMPT TO OPERATE THE 
GYPFAST TOOL IF PARTS ARE LOOSE, 
DAMAGED, OR MISSING.

 Make sure all  

screws and nuts are properly tightened and all 
parts are properly installed and in good work-
ing order . If parts are missing, don’t attempt to 
make temporary repairs . . .contact your Sales 
Representative immediately . 

12. NEVER DRIVE FASTENERS ON TOP OF 
OTHER FASTENERS OR TOO CLOSE TO OTHER 
FASTENERS.

 Fastening on top of or too close to 

other fasteners can cause the fastener to ricochet 
and cause serious injury . Fasten only in areas 
where the entire shank can penetrate . 

13. NEVER FIRE INTO VERY HARD OR 
BRITTLE MATERIALS SUCH AS CAST IRON, 
TILE, GLASS, OR ROCK.

 These materials can 

shatter, causing sharp fragments and/or the  
fastener to fly freely . 

SAFETY INSTRUCTIONS

       

5

SAFETY INSTRUCTIONS

Summary of Contents for GYPFAST

Page 1: ...RAMSET GYPFAST OPERATOR S SAFETY OPERATING INSTRUCTION MANUAL DANGER READ AND OBEY ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE OPERATING TOOL GAS POWERED LOW VELOCITY PISTON TYPE FASTENING TOOL...

Page 2: ...ents Each section of the manual is written with you the tool operator in mind We have left out all of the technical terms so that you can readily understand how to get the maximum performance from you...

Page 3: ...d Filter the Motor Housing the Nose and the Safety Yoke The Magazine Assembly contains the Magazine Magazine Dow and Hinge Pin SPECIFICATIONS Dimension Height 16 inches Length 13 inches Weight 7 9 pou...

Page 4: ...sing flammable gas This tool must be operated only in a well ventilated environment because the tool exhausts carbon monoxide similar to a gas chain saw or lawnmower Exposure to carbon monoxide may ca...

Page 5: ...NOT LOAD FASTENERS WITH THE TRIGGER OR SAFETY YOKE DEPRESSED When loading fasteners into the GypFast tool you must avoid pulling the Trigger or while having the Safety Yoke depressed When the tool is...

Page 6: ...49 C may cause the Fuel Cells to leak or burst releasing the flammable gases and creating a risk of fire or explosion 17 FUEL CELL DISPOSAL Never attempt to puncture crush burn or refill a Fuel Cell...

Page 7: ...r area Ramset s involvement in this program is part of our commitment to preserving our envi ronment and conserving our natural resources CHARGING INSTRUCTIONS 1 Connect the round plug of the wall mou...

Page 8: ...llustration is a closeup of the side of the GypFast tool On the side of the Handle is a small plastic lens This is the Battery Voltage Indicator Light To check the battery voltage the LED on the right...

Page 9: ...queezes the inner fuel container much as you squeeze a tube of toothpaste This squeezing action ensures that all the fuel is used and that the GypFast tool can operate in any position Because of this...

Page 10: ...er Assembly and pushing down until the Actuator Cover snaps into position OUTDOOR WEATHER AND THE GYPFAST TOOL Use the GypFast tool outdoors in clear weather when the Tool Fuel Cell and Battery are be...

Page 11: ...3 RELEASE TRIGGER LIFT THE TOOL The Combustion Chamber opens Fan exhausts hot gases and cools internal components NOTE If no additional cycles are made fan will run for 7 seconds and then shut off TO...

Page 12: ...D in the Handle of the GypFast tool When encountering a problem the first step should always be to make sure the Battery has enough energy to operate the tool If the light is red recharge the Battery...

Page 13: ...the outside of the tool using a soft cloth and a mild degreasant like paraffin CAUTION Never use highly volatile solvents such as gasoline to clean the tool Do not allow any solvent to enter the inte...

Page 14: ...3 Place the Battery in its Charger only if it needs charging as indicated by the red charge light in the handle 4 Wipe your GypFast tool with a clean soft cloth 5 Check Adjustable Nosepiece Element to...

Page 15: ...not occur Contact Authorized Ramset Distributor Sales Representative for service Replace Fuel Cell Contact Authorized Ramset Distributor Sales Representative for service Contact Authorized Ramset Dis...

Page 16: ...e minute Pull trigger If fastener does not drive there is a leak that requires service Use only fasteners meeting Ramset specifications Clear jam according to Operating Manual Check Fuel Cell accordin...

Page 17: ...is warranty does not apply to part replace ment required due to normal wear This warranty is void as to any tool which has been subjected to misuse abuse accidental or intentional damage use with fast...

Page 18: ...NTER VISIT OUR WEB SITE AT WWW RAMSET COM OR CALL 800 241 5640 Concrete Fastening Systems Glendale Heights IL 60139 800 RAMSET6 1 800 726 7386 www ramset com Buy with Confidence Buy From Your Authoriz...

Reviews: