8.9

Weight

0 - 305

Impact frequency at rated speed

m/s

2

1,5

Uncertanty K

45

80

125

DynaDrill™ 585

kg

W

1500

Rated Power input

Restart Protection

12.5

J

Impact energy per stroke according to EPTA-procedure 05/2009

mm

mm

mm

m/s

2

m/s

2

8

Vibration emission value 9h

II

Protection Class

mi

-

n

1

P

1

E

n

0

Ø max.

Ramset™ Vibration Control

✔ 

✔ 

Maintenance and Cleaning

 

X

Before any work on the machine itself, pull 

the mains plug. 

 

X

For safe and proper working, always keep 

the machine and ventilation slots clean.

 

X

A damaged dust protection cap should 

be changed immediately. We recommend 

having this carried out by the Ramset 

Service Centre.

If the replacement of the supply cord is necessary, this 

has to be done by the Ramset Service Centre in order 

to avoid a safety hazard.

Service Indicator

(see Fig. 9, page 11)
When the carbon brushes are worn out, the machine 

switches itself off. This is indicated approx. 8 hours 

beforehand by the lighting or blinking of the service 

indicator. The machine must then be sent to the 

Ramset Service Centre. Addresses are listed on the 

last page.
“After-sales Service and Application Service”.
Service indicator flashes in regular intervals, the 

machine is defective. In this case, do not continue 

to use the machine and send it immediately to the 

Ramset service centre.

After-sales Service and 

Customer Assistance

Our after-sales service responds to your questions 

concerning maintenance and repair of your product  

as well as spare parts. 

Australia 

New Zealand 

Tel:   1300 780 063  

Tel:   +64 9444 3510 

Fax:   1300 780 064 

Fax:  +64 9444 2864 

www.ramset.com.au 

www.ramset.com.nz

Disposal

The machine, accessories and packaging should be 

sorted for environmental-friendly recycling.
Do not dispose of power tools into household waste! 

Only for EC countries:

According the European Guideline 2012/19/EU for 

Waste Electrical and Electronic Equipment and its 

implementation into national right, power tools that are 

no longer usable must be collected 

separately and disposed of in an 

environmentally correct manner.

Subject to change without notice.

Summary of Contents for DynaDrill 585

Page 1: ...TO REDUCETHE RISK OF INJURY USER MUST READ OPERATOR S MANUAL 8kg Combi Hammer Operators Manual DynaDrill 585 RRC RAMSET ROTATION CONTROL R...

Page 2: ...DynaDrill 585 Operators Manual 2...

Page 3: ...fety X X Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medication A moment...

Page 4: ...rce must correspond with the data on the type plate of the machine X X Use appropriate detectors to determine if utility lines are hidden in the work area or call the local utility company for assista...

Page 5: ...Reaction direction Next step of action Prohibited action Hammer Drilling Chiselling Vario Lock Switching On Switching Off On Off switch lock on Releasing the On Off switch Restarting Protection Concre...

Page 6: ...et has been measured in accordance with a standardised test given in EN 60745 and may be used to compare one tool with another It may be used for a preliminary assessment of exposure The declared vibr...

Page 7: ...eforehand by the lighting or blinking of the service indicator The machine must then be sent to the Ramset Service Centre Addresses are listed on the last page After sales Service and Application Serv...

Page 8: ...DynaDrill 585 Operators Manual 8 1 2 3 2 4 5 1 2 1...

Page 9: ...DynaDrill 585 Operators Manual 9 1 3 2 2 1 3 4 5...

Page 10: ...DynaDrill 585 Operators Manual 10 8 6 7...

Page 11: ...DynaDrill 585 Operators Manual 11 9 8h...

Page 12: ...CEMENT REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY RamsetTM PRODUCT IF YOU DO NOT AGREE TO THIS CONDITION YOU SHOULD NOT PURCHASE THE PRODUCT IN NO EVENT SHALL R...

Reviews: