CONNECT THE COOKTOP TO GAS
Shut off the main gas supply valve before disconnecting the old cooktop and leave it off until the
new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when
you turn the gas back on.
Never use an old connector when installing a new cooktop.
CONVERTING TO LP GAS (or converting to natural gas from LP)
This cooktop leaves the factory set for use with natural gas or LP gas. Please read carefully in the
rating label information to confirm this.
PROVIDE ADEQUATE GAS SUPPLY
Your cooktop is designed to operate at a pressure of 5” of water column on natural gas or,
if designed for LP gas (propone or butane), 10” of water column.
Make sure you are supplying your cooktop with the type of gas for which it’s designed.
This cooktop is convertible for use on nature or propane gas. If you decide to use this
cooktop on LP gas, conversion must be made by a qualified LP installer before
attempting to operate the cooktop on that gas.
For proper operation, the pressure of natural gas supplier to the regulator must between
5” and 13” of water column. For LP gas, the pressure supplied must be between 10” and
13” of water column.
When checking for proper operation of this regulator, the inlet pressure must be at least
1” greater than the operating pressure as given above.
A flexible metal appliance connector used to connect the cooktop to the gas supply line
should have an I.D. of 1/2” and be 5 feet in length for ease of installation. In Canada,
flexible connectors must be single wall metal connectors no longer than 6 feet in length.