Some  of  the  customers  who  purchased  220V  AC  induction/electric  cooktop 

(EC2-30, EC4-60 & ICQ2-31C1...etc.) have asked about the electrical connection. 

The  following  are  a  set  of  instructions  that  customers  have  found  useful.  Please 

first  note that  our  unit  uses  the  standard  US color  code  convention  -  Black (hot), 

White (neutral) and Green (ground), but that some of the units might use the British 

convention - Brown (hot), Blue (neutral) and Yellow/Green (ground). In either case, 

you will need to do the following: 

 

 

For connection to a junction box without the use of a 220V plug: 

 

Connect  the  hot  wire  from  the  unit  to  the  black  wire  in  the  circuit  box  (in 

junction box) and the neutral wire from the unit to the red wire from the circuit 

box (in junction box).   

 

Connect the ground wire from the unit to the white wire from the circuit box 

(in junction box).   

 

Fasten the ground wire coming in from the circuit box (in junction box) to the 

ground lead on the junction box.   

 

The hot and neutral wires from the induction unit are used as both hot lines 

and must be connected with the two hot lines from the circuit box - the black 

and the red lines.   

 

 

 

 

 

 

 

Summary of Contents for EC2-27

Page 1: ...User Manual EC2 27 EC2 30 EC4 60 Ramblewood Green WWW RAMBLEWOODGREEN COM ...

Page 2: ... the liability of the user You should not store or place flammable or highly flammable liquids materials on top of or near this product Items made from aluminum plastic or plastic film should also be kept away from the appliance as they may fuse to the surface Infant should be kept away from this appliance If children are allowed in kitchen please keep them under close supervision at all times Old...

Page 3: ...pecifications Product specifications and Electrical details MODELS EC2 27 EC2 30 EC4 60 Voltage 110 120V 60Hz 220 240V 60Hz 220 240V 60Hz Current 19 8A 21 7A 13A 28A Burner Power 1400W 1200W 1800W 1200W 1800Wx2 1200Wx2 Max power kW 2180 2600W 3000 W 6000 W Front Side control operation YES YES YES Electrical cable type 3 core x 3 31mm 3 core x 1 5 mm 3 core x 2 5 mm Control panel layout and Cooking...

Page 4: ...ise to select heating power level Numbers on the dial indicate the power level from 1 to 9 with 9 is the maximum Marking below each knob indicates the zone it controls The areas where the heat radiates are marked by 2 or 4 circles on ceramic glass surface Saucepans must be positioned exactly on top of these zones for efficient heating Cleaning and maintenance Glass surface should be cleaned regula...

Page 5: ...check the following items are contained within the box 1 hob 1 Ceramic hob scraper 1 Installation and instruction manual 4 Fixing brackets 4 Fixing screws 4 Spring clips 1 Sealing strip Positioning The adjacent furniture must be able to withstand a minimum temperature rise of 85 C above the ambient temperature MODEL A B C D E EC2 27 290mm 510mm 270mm 490mm 57mm EC2 30 290mm 510mm 270mm 490mm 53mm ...

Page 6: ... it Carefully turn the hob upside down and place it on a cushioned mat Apply the sealing strip provided around the edge of the appliance Do not leave a gap in the sealing agent or overlap the thickness IMPORTANT Do not use a silicon sealant to seal the appliance against the aperture This will make it difficult to remove the hob from aperture in future for service ...

Page 7: ... into the aperture hole that you have cut out On the underneath of the hob locate the fixing brackets B and turn them so that they locate on the underneath of the worktop and the hob Fully tighten the screws C to secure the hob into position WARNING THIS APPLIANCE MUST BE EARTHED This appliance must be wired into a 30 A fused spur outlet having 3 mm contact separation and placed in an easily acces...

Page 8: ...ified technician per national local safety regulation guideline The main terminal block is located on the underside of the hob and terminals are accessible by removing the terminal block cover screw EC2 27 EC2 30 EC4 60 The cable connections must be in accordance with the diagram located on the bottom of the hob ...

Page 9: ... must be about 10 mm longer than the live and neutral wires The White Blue neutral wire must be connected to the terminal marked with letter N The Black live wire must be connected to the terminal marked with letter L Please insure cable is not kinked or trapped when the hob is in position ...

Page 10: ...ow Green ground In either case you will need to do the following For connection to a junction box without the use of a 220V plug Connect the hot wire from the unit to the black wire in the circuit box in junction box and the neutral wire from the unit to the red wire from the circuit box in junction box Connect the ground wire from the unit to the white wire from the circuit box in junction box Fa...

Page 11: ... circuit box in junction box to the ground lead on the junction box Again note that the hot and neutral wires from the induction unit are used as both hot lines and must be connected with the two hot leads prong on the 220V plug We have attached sample pictures of 220V plug and face plate at the end of the manual posted in http ramblewoodgreen com upload 220 20V_wiring 28 7 15_less photo pdf or ht...

Reviews: