INSTALLATION 

 

The  installation  and  service  must  be  conducted  by  a  qualified  technician,  in  accordance 
with national & local regulation.   
 

 

Product dimensions and Aperture dimensions:     

 

Unpacking the appliance 

 

 

When unpacking the appliance please check the following items  are contained within the 
box:   
 
1 hob   
1 Ceramic hob scraper   
1 Installation and instruction manual   
4 Fixing brackets   
4 Fixing screws   
4 Spring clips   
1 Sealing strip 

 

                                       

 

Positioning 

 

The  adjacent  furniture  must  be  able  to  withstand  a  minimum  temperature  rise  of  85°C 
above the ambient temperature. 
   

MODEL 

E

 

EC2-18 

290mm 

510mm 

270mm 

490mm 

60mm 

   

Summary of Contents for EC2-18

Page 1: ...User Manual EC2 18 Ramblewood Green WWW RAMBLEWOODGREEN COM ...

Page 2: ...e the liability of the user You should not store or place flammable or highly flammable liquids materials on top of or near this product Items made from aluminum plastic or plastic film should also be kept away from the appliance as they may fuse to the surface Infant should be kept away from this appliance If children are allowed in kitchen please keep them under close supervision at all times Ol...

Page 3: ... Switch 3 Burner Display 4 Minus 5 Plus 6 Burner Power Setting Indicator Power level can be set only if this indicator is blinking 7 Timer Switch 8 Timer Display 9 Children Safety Lock 10 Burner Power On Indicator 11 Timer Indicators Time can only be set when this indicator is blinking Top Indicator is for top burner bottom Indicator is for bottom burner 12 Children Safety Lock Indicator Model Nam...

Page 4: ...selecting the Burner Switch 3 Set power by pressing Plus or Minus sign First touch power level display will show 5 OR first touch display will show 9 4 User can only adjust the power of one burner at a time 5 Set power to 0 burner will be turned off 6 The burner will be On Off alternatively within power levels 1 to 8 The On duration increases gradually as the power level increases When the power l...

Page 5: ... or Minus 5 Turn off timer When time is up timer will sound for 2 minutes and you can turn off the sound by touching any button If user wanted to turn off burner in advance please set timer to 00 or turn off the Main Power Switch to reset WARNING Do not use commercial simmering aids as these can create excessive heat that can damage the appliance Do not use the glass ceramic surface of the hob as ...

Page 6: ...rface should be cleaned regularly IMPORTANT Clean the unit when power is off the glass surface is cool Using the Scraper The scraper should be placed against glass surface at an angle Residues can be removed by sliding the blade gently ...

Page 7: ...When unpacking the appliance please check the following items are contained within the box 1 hob 1 Ceramic hob scraper 1 Installation and instruction manual 4 Fixing brackets 4 Fixing screws 4 Spring clips 1 Sealing strip Positioning The adjacent furniture must be able to withstand a minimum temperature rise of 85 C above the ambient temperature MODEL A B C D E EC2 18 290mm 510mm 270mm 490mm 60mm ...

Page 8: ... it Carefully turn the hob upside down and place it on a cushioned mat Apply the sealing strip provided around the edge of the appliance Do not leave a gap in the sealing agent or overlap the thickness IMPORTANT Do not use a silicon sealant to seal the appliance against the aperture This will make it difficult to remove the hob from aperture in future for service ...

Page 9: ...neath of the hob locate the fixing brackets B and turn them so that they locate on the underneath of the worktop and the hob Fully tighten the screws C to secure the hob into position Wiring to 220V AC outlet The Green yellow earth wire must be connected to the Earth marked in the AC outlet circuit box or the plug It must be about 10 mm longer than the two Live wires The Black Red L1 L2 wires must...

Page 10: ... appliance must be wired into a 30 A fused spur outlet having 3 mm contact separation and placed in an easily accessible position adjacent to the unit Cable type EC2 18 220V 240V 3x14AWG UL Replacing the power supply cable If the power supply cord is damaged it must be replaced by manufacturer or qualified technician per national local safety regulation guideline The main terminal block is located...