This is a complete set of protections that
monitors the main amp parameters (load
status, signal input, temperature, current,
etc.) in order to draw from the power sup-
ply only the precise amount of current
required to maintain safe operation during
hazardous or extreme working conditions. 

This system controls the amount of power
that the amp delivers under three basic
circumstances:

1.- The power-on sequence, where output
is inhibited until the amp circuits are ready
to operate. This routine is repeated at
every restart, not just when the power
switch is activated.

2.- When internal temperatures rise to
near thermal shutdown point due to
unfavourable operating conditions. Here
the system takes control, restricting cur-
rent so as to maintain operational continu-
ity at the precise power level which the
amp is capable of withstanding at that par-
ticular moment.

3.- Excessive mains current consumption.
This event only occurs either under labora-
tory conditions (long term sinusoidal signal
testing with dummy loads) or, for example,
in field applications in conditions of pro-
longed acoustic howl-round. Here PMS
takes control to avoid any damage to the
speakers and to prevent the mains break-
er from tripping or the fuses blowing.

The RAM Audio ICL2 is an anticlip system
to avoid speaker failure and provide more
acceptable sound quality even when clip-
ping occurs. With the ICL2 system you
don't lose the music “punch” but the
speakers are kept under control.

SOA Sentry protection effectively limiting
the power that the amp could deliver into
an incorrect load or to a direct short-cir-
cuit. This avoids power transistor failure.

Faulty Channel Management system to
avoid entire device shutdown.

FCM

™ 

Faulty Channel Management

PMS

™ 

- Power Management System

SSP

™ 

SOA Sentry Protection

ICL2

™ 

- Intelligent Clip Limiter

Vollständiges Set von Schutzfunktionen
das die wichtigsten Endstufenparameter
überwacht (Auslastung, Signaleingang,
Temperatur und Stomstärke) um vom
Netzanschluss nur die Menge Strom zu
beziehen, die für den betriebssicheren
Arbeitsablauf notwendig ist

Dieses System reguliert die von der
Endstufe abgegebenen Leistung in 3
Fällen:

1.- Anschaltevorgang: Der Ausgang wird
gehemmt bis die Endstufe voll funktions-
bereit ist. Dieser Vorgang wiederholt sich
bei jedem Neustart, nicht nur wenn der
Leistungsschalter aktiviert wurde.

2.- Wenn die Innentemperatur aufgrund
ungünstiger Arbeitsbedingungen nahe des
Grenzwertes steigt, bei dem die automa-
tische Ausschaltefunktion aktiviert würde,
um eine Überhitzung des Systems zu ver-
meiden. In diesem Fall übernimmt das
System die Kontrolle und reduziert die
Stromzufuhr auf ein Niveau, dass die
Endstufe in dieser Situation aushalten
kann.

3.- Überhöhter Stromverbrauch: Diese
Situation stellt sich ausschließlich unter
Laborbedingungen ein (in sinusförmigen
Langzeitsignaltests mit Dummylasten oder
in langanhaltenden akustischen Feedback
Bedingungen. Hier greift das PMS System
ein um eine Schädigung der Lautsprecher
zu vermeiden und um zu verhindern dass
der Hauptunterbrecher ausgelöst wird oder
die elektrischen Sicherungen durchbren-
nen.

Das RAM Audio ICL2 ist ein Anticlipsystem
das das Versagen der Lautsprecher ver-
meidet und auch wenn Clipping auftritt
noch eine bessere Tonqualität gewährleis-
tet. Mit dem ICL2 System verlieren Sie
den “Punch” nicht, und der Lautsprecher
arbeitet kontrolliert.

SOA Die Leistung, die die Endstufe an
inkorrekte Lasten oder an einen
Kurzschluss abgeben könnte wird wirksam
limitiert. Dies verhindert die Zerstörung der
Leistungstransistoren.

Faulty Channel Management system to
avoid entire device shutdown.

FCM

™ 

Faulty Channel Management

SSP

™ 

SOA Sentry Protection

PMS

™ 

- Power Management System

ICL

™ 

- Intelligent Clip Limiter

Protection Systems

Ceci est un ensemble complet de protec-
tions qui surveille les paramètres princi-
paux de l'ampli: état de l'impédance (char-
ge), signal d'entrée, température, courant,
etc. pour obtenir de l'alimentation la quan-
tité précise minimum de courant et ainsi
permettre à l'ampli de continuer à fonction-
ner en sécurité dans des conditions extrê-
mes, ou voire dangereuses au maintien de
son intégrité électronique.
Ce système contrôle la quantité de cou-
rant que l'ampli peut utiliser dans les cir-
constances suivantes:
1.- Lors de la mise sous tension, ou la sor-
tie est coupée jusqu'a ce que l'ampli est
100% prêt dans tous ses circuits. Ce pro-
cessus est repeté, non seulement a la
mise en marche, mais chaque fois que
l'ampli se remet en fonctionnement.
2.- Quand la température interne de l'am-
pli est proche de la coupure automatique
de sécurité, (thermal shutdown), dans des
conditions de fonctionnement adverses.
Dans ce cas, le système prend le contrôle,
et oblige l'alimentation a ne délivrer que le
courant nécessaire a maintenir le fonction-
nement, au niveau que l'ampli est capable
de maintenir à ce moment précis, dans
des conditions données. 
3.- Dans le cas de consommation excessi-
ve de courant. Cette éventualité ne se
pressente que dans des conditions de
laboratoire lors de tests prolongés avec
des signaux sinusoïdaux ou dans les cas
de realimentation acoustique prolongée
sur la scène. Ici le PMS prend le contrôle
pour éviter d'endommager les haut-par-
leurs, de faire sauter les systèmes de pro-
tection du secteur ou même les fusibles.  

Le ICL2 de RAM Audio est un système
anti-écrêtage qui permet un rendement
des haut-parleurs optimisé et offre un mei-
lleur résultat auditif quand l'écrêtage est
pressent. Le ICL2 permet à la musique de
garder son punch mais sauvegarde les
haut-parleurs.

Le SOA est un système sentinelle qui limi-
te de manière efficace le courant que l'am-
pli peut donner sous une charge inadé-
quate ou sous court-circuit direct. Ce
système protége les transistors de sortie.

Faulty Channel Management system to
avoid entire device shutdown.

FCM

™ 

Faulty Channel Management

SSP

™ 

SOA Sentry Protection

PMS

™ 

- Power Management System

ICL

™ 

- Limiteur Intelligent d'écrêtage 

Systèmes de

Protection

13

Schutzschaltungs-

systeme

Summary of Contents for 6000V

Page 1: ...TICE D EMPLOI BEDIENUNGSANLEITUNG P 6546 564 QXPDQXDoc 4 11 2011 by C E Studio 2 s l Spain EEC http www ramaudio com e mail support ramaudio com Professional Power Amplifiers V Series 6000 9000 12000 9004 9044 12004 12044 ...

Page 2: ... sich an qualifiziertes Personal Es handelt sich um ein Gerät der Klasse I IMPORTANT Clean the front panel filters regularly Extract the filters removing the front panel grid unscrewing the thumbscre ews placed at the sides of the grid Clean the filters using water and deter gent Place the grid filter introducing first the internal side and screwing the thumbscrew 1 VORSICHT GEFAHR EINES ELEKTRISC...

Page 3: ...l other names are trademarks of their respective companies 0 Sicherheitshinweise 1 Allgemeine Anweisungen 1 1 Einleitung 1 2 Allgemeine Eigenschaften 2 Lokalisierung der Funktionen 2 1 Frontplatte 2 2 Rückplatte 3 Anschluss und Inbetriebnahme 3 1 Anschlüsse 3 1 1 Dual Kanalmodus 3 1 2 Link Kanalmodus 3 1 3 Bridge Kanalmodus 3 2 Konfiguration 3 3 Problemlösung 4 Technische Spezifikationen 4 1 Schut...

Page 4: ...d Dual SMPS Digital Control with extra large LCD display user interface Channel Temperature and Output Level Monitor in the LCD USB port for firmware update and DSP control 25 position Gain Bridge mode Input Links and ICL front panel config urable Digital Potentiometers with Encoder control RAM Audio Power Management System Hi Efficiency Heavy Duty Audio Power section for extreme use Easily remova...

Page 5: ...Seite 13 ICL Die LED zeigt an dass der Intelligent Cliplimiter arbeitet siehe Seite 13 Beleuchteter Hauptstromschalter Position I Schaltet die Endstufe ein Blaue LED leuchtet Position O Schaltet die Endstufe aus Position II optional Stand by Modus Die Endstufe kann über Ethernet eingeschaltet werden Gelbe LED Display siehe Seite 10 USB Connector for firmware upgra de and optional DSP control 5 4 3...

Page 6: ...ltung der Eingangssignale mehrerer Endstufen Lautsprecheranschluss Neutrik Speakonstecker zum Anschluss an Lautsprecher Mains Power Cord to connect the amplifier to the mains network The color code is Blue Neutral Brown Live single phase Yellow green Protective Earth 3 2 2 Rückplatte 2 1 2 Lokalisierung der Funktionen 5 Controls Where and What Voir Fig Connecteurs Neutrik XLR feme lle d entrée des...

Page 7: ... Asymetrisches Signal Die Belegung der XLR Pins ist wie folgt 1 Masse 2 Signal 3 Masse ACHTUNG Wenn Sie ein asymetris ches Signal anschließen und Pin 3 nicht an Masse anschließen erzeugt dies einen Verlust von 6dB 1 4 der Leistung der Endstufe am Ausgangssignal Die Endstufe verfügt über eine parallele XLR Buchse für die Zusammenschaltung mehrerer Endstufen 3 1 Anschlüsse Installation and Operation...

Page 8: ...c le entrée de signal linked au le canal consécutif Voir Fig Sélectionner le mode BRIDGE voir page 9 Selectionnez le sensibilité choisie réglage usine 32dB Brancher le signal modulation sur le connecteur XLR femelle du Canaux A ou Canaux C pour 4 canal modèles Brancher les HP sur les 1 2 des Speakons de sortie du canaux A ou C Le 1 est la borne positif dans ce mode de fonctionnement Utilisser les ...

Page 9: ...3 4 Dual Channel 2 Ch models 2 Ch models 8 5 Link Inputs Bridge Mode 2 Ch models ...

Page 10: ...3 4 Dual Channel 4 Channel models 4 Channel models 4 Channel models 5 Link Inputs Bridge Mode Bridge Dual Mode 3 Channels Mode 9 ...

Page 11: ... protection Display Mode Change between Channel Attenuation or Vu meter mode in the Main Screen Operating Time shows the amplifier total time operation Firmware Version shows the Amp Control firmware ver sion You can upgrade it using the USB port Menu navigation to access to the Menu screen you have to press the CH A encoder knob from the Main Screen Turning the CH A encoder knob you access to the...

Page 12: ...e to remove the input connector of the linked channel Amplifier Gain you can change independently the amplifier gain for each channel from 26dB to 38dB 0 5dB steps Enter in Edit mode and use the corresponding channel knob to modify it Amplifier Mode it configures the amplifier in Dual or Bridge mode In Edit mode use the CH A or CH C channel knob to change the option Attenuators Link you can link a...

Page 13: ...findet sich im Anschaltevorgang das Ausgangssignal wird so lange gehemmt bis die Enstufe voll funk tionsbereit ist Die Innentemperatur steigt aufgrund ungünstiger Arbeitsbedingungen nahe des Grenzwertes bei dem die automa tische Ausschaltefunktion aktiviert wird um eine Überhitzung des Systems zu vermeiden Überhöhter Netzstromverbrauch 3 3 Problemlösung Installation and Operation En cas d utilisat...

Page 14: ...Feedback Bedingungen Hier greift das PMS System ein um eine Schädigung der Lautsprecher zu vermeiden und um zu verhindern dass der Hauptunterbrecher ausgelöst wird oder die elektrischen Sicherungen durchbren nen Das RAM Audio ICL2 ist ein Anticlipsystem das das Versagen der Lautsprecher ver meidet und auch wenn Clipping auftritt noch eine bessere Tonqualität gewährleis tet Mit dem ICL2 System verl...

Page 15: ...on 20Hz 20kHz 0 05 Intermodulation Distortion SMPTE 0 05 Damping Factor 20 500Hz 8Ω 500 Crosstalk 20Hz 20kHz 80dB Voltage Gain 26dB to 38dB 0 5dB steps Sensitivity Rated Power 26 32 38dB Gain 4 2 1 V 4 9 2 5 1 2 V 5 7 2 8 1 4 V 3 5 1 7 0 9 V 4 8 2 4 1 2 V 4 1 2 1 V 5 6 2 8 1 4 V Signal to Noise Ratio 20Hz 20kHz 113dB 115dB 116dB 112dB 115dB 113dB 116dB Required AC Mains Operating Voltage 50Hz 60Hz...

Page 16: ...factured in the EEC by C E Studio 2 s l Pol Ind La Figuera C Rosa de Luxemburgo nº 34 46970 Alaquas Valencia SPAIN Phone 34 96 127 30 54 Fax 34 96 127 30 56 http www ramaudio com e mail support ramaudio com ...

Reviews: