Installing the RSR-DLI
The RSR-DLI works off a 12V DC, a suitable power supply attached to a 13A plug is provided with
the product. When successful powered up LED 2: the “Power LED” will illuminate.
Note that this power supply is to power the circuit board and DLI output of the RSR-DLI only. The
power for the fittings themselves is provided directly to the ballast, the output from the RSR-DLI is
a control signal only.
Adding the RSR-DLI as a device
For the RSR-DLI to operate correctly with a Rako system some initial
setup must be performed. This is done using a PC running Rasoft Pro
(RSR-DLI is not supported by RASOFT classic) and communicating via
a RAKO Bridge/HUB or RAMPI programming device.
Open the Project File for the installed Rako system and make sure that
Rasoft is connected to a communication device.
NB
The communication window at the bottom right should indicate whether a device is connected or not. In this
case a RAMPI is connected. For instructions on how to connect to a communication device see Rasoft Pro
programming guides and applicable instruction manuals.
- Select “File” - “New device” to bring up the “New device Wizard” and choose “RSR-DLI” from the
list.
- Choose a suitable device name (if you have multiple RSR-DLIs make sure it is identifiable from
this description). Leave “Device ID” blank with the “Automatic ID” box checked.
- Associate the RSR-DLI to a room from the drop down menu. The room selected here will set the
“Local Room” for this device.
RSR-DLI
Manual Version 3.0.3