STEP 3
Connect the 48V DC input
supply.
STEP 4
Connect the load, there can be
up to four controllable outputs.
NB
Ensure that the connected load
is wired in series, as parallel
wiring will cause damage to the
RLED40CC1 and the load.
STEP 5
Fix the cable clamps over the
cables to secure them in place,
and replace the cover.
4 Initial Checks
●
When power is initially connected to the module, the load should power up to full
brightness.
●
The clear button can be used as a manual on/off switch to test the circuit.
●
The internal LED behind the clear button will flicker when the module receives any
Rako wireless message and is a useful diagnostic indicator. The LED feedback
becomes inactive after 20 minutes to avoid a nuisance light spill but can be
re-activated by pressing the clear button.
5 Programming the RLED45CC1
Once the RLED45CC1 has powered up and has been tested working with the setup button,
the device is ready to be programmed. For instructions on how to program the
RLED45CC1, see the
RLED45CC1
Manual Version 2.0.0