rako RLED45CC1 Instruction Manual Download Page 3

3 Installation of the RLED45CC1

Installation should only be carried out by a competent electrician.
DO NOT CONNECT DIRECTLY TO THE MAINS SUPPLY.

All LED fittings should be wired in

series.

RLED45CC1 modules should be mounted in areas that are adequately ventilated,
dry, and outside of any enclosed metal casings that may interfere with the Wireless
signal.

Modules should be mounted vertically, with the terminals at the bottom, or
horizontally.

While the modules are designed to be maintenance-free, they should be mounted
in an accessible location should investigation or re-addressing of the units be
necessary.

Ensure that the cable clamps are fitted tightly to secure the cables.

STEP 1

Remove the covers and cable
clamps.

STEP 2

Select the Constant Current
output on the RLED45CC1 to
match the rating on the load.

1000mA

700mA

600mA

500mA

350mA

NB

Do not set multiple jumpers.

RLED45CC1

Manual Version 2.0.0

Reviews: