19

Six、Product Wiring

15

Tail Wire Interface

External Interface Hardware Wiring Instructions

Type

Port

Instruction

Network Port

RJ45

Support 10/100Mbps

Relay

NC

COM

NO

Relay normally closed end/common end/normally open end. Generally, the
door lock power supply is connected to the COM terminal, and then
according to the type of door lock, the relay power supply is negatively
connected to the NO port or the NC port. Note: The maximum load of relay
contacts is 1A

Exit button

IO5

GND

Detect the key to open the door control signal, input

Call

the

police

IO4

GND

Detect fire linkage control signal, input

Reset

Upgrate

GND

Support manual reset and upgrade

Serial port

RS232 TX

RS232 RX

Support serial RS232

Wiegand

WG_D1

WG_D0

Wiegand output interface, support 26bit/34bit Maxtocol

Input power

GND

12V+

Power Input: 12V DC

USB

USB_HOST-4P

External reserved USB interface to connect peripherals

Summary of Contents for F1MAX

Page 1: ...www scanmaxai com 1 19 F1 Max Face Terminal Manual Model F1MAX 5 inch Android 11 Version V1 0 Shenzhen Rakinda Technologies Co Ltd...

Page 2: ...www scanmaxai com 2 19...

Page 3: ...site magnetic door installation reference instructions 12 6 2 1Magnetic door system installation diagram 12 6 2 2Magnetic door system wiring diagram 12 Seven Installation Instructions 7 1Wall Mount I...

Page 4: ...ace dynamic recognition Maxvides users with a safe environment The Product is based on 200W RGB 200W IR binocular camera supports WIFI 10 100M networking and rich peripheral security interfaces meets...

Page 5: ...face recognition algorithm face recognition can be completed quickly 4 Anti counterfeiting Binocular face recognition support live detection 5 Interact Adopt live detection 5 inch ultra clear touch sc...

Page 6: ...m alloy material Camera Type RGB IR Resolution 2 million pixels 2 million pixels Vertical wide angle 65 65 Horizontal wide angle 40 40 White fill light Supported Infrared fill light Supported Core par...

Page 7: ...stic full Netcom Identification method Face Supported IC card Supported Optional QR Code Reader Supported Optional Interface Data port USB 2 0 2 Replay 1 Serial port RS232 1 Wiegand 26bit 34bit Maxtoc...

Page 8: ...SD IEC61000 4 2 LEVEL3 Maxtection level IP41 Installation method Wall mounted F1 Max No Content 1 Host 1 2 Wall Mount Kit 1 3 4G module and external antenna optional 1 4 Power Adapter 1 5 Wall Mounted...

Page 9: ...ket Fixing Screw 2 RGB Camera 3 IR Camera 4 USB2 0 5 White Fill Light White 6 Infrared Fill Light 7 Multi point Capacitive Touch Screen 8 Sound Hole 9 Speaker Mesh 10 QR Code Scanning Area 11 NFC Card...

Page 10: ...lock the relay power supply is negatively connected to the NO port or the NC port Note The maximum load of relay contacts is 1A Exit button IO5 GND Detect the key to open the door control signal inpu...

Page 11: ...www scanmaxai com 11 19 6 1 Integrated Harness Wiring Instructions USBA 2 0_OTG Equipment upgrade debugging U disk...

Page 12: ...scanmaxai com 12 19 6 2 On site magnetic door installation reference instructions 6 2 1Magnetic Door System Installation Diagram 6 2 2 Magnetic Door System Wiring Diagram Seven Installation Instructi...

Page 13: ...ing the recognition speed and avoid facing the glass door or glass wall Web environment It is recommended to install it in an environment with a smooth network to avoid the poor network affecting the...

Page 14: ...ace and the machine when registering is 0 5 0 8 meters Several methods of affecting the recognition effect Register Comparasion Register Comparasion Inconsistent posture Different heights Register Com...

Page 15: ...y on the top of the sliding door and the factory built 12V1 5A power supply is connected during installation The 12V end of the adapter the 220V power cord of the adapter is directly inserted into the...

Page 16: ...k the door wireless network will also Very stable can consider using wireless 7 1 2 Dimensions and hole positions of the wall bracket Fix the wall mounted board and the host with a machine tooth cup h...

Page 17: ...es and fixing screws on the fixed device Step 4 Lock Fasten the device with the main unit and the wall mount with screws wire adjust the wiring length until the device can be snapped into the wall mou...

Page 18: ...us material of the part exceeds the limit specified in GB T26572 This labeling period refers to the period ten years and the harmful substances in electrical and electronic Products will not be releas...

Page 19: ...arranty card and purchase invoice are the Maxofs that the company Maxvides after sales service to customers 1 It is valid only after the dealer affixes the official seal 3 In one of the following situ...

Reviews: