4. Set the Device EUI.
Get the Device EUI number from the ChirpStack register.
5. Set the Application EUI.
Get the Application EUI number from the ChirpStack register.
📝
NOTE:
Remember, the Application EUI parameter is not required in the ChirpStack platform; therefore, it is
possible to use the same id as the Device EUI. Otherwise, the firmware will complain.
6. Set the Application Key.
Get the Application Key from the TTN register.
7. Save RAK4600 parameters.
Reset the RAK4600 to save the parameters.
Figure 57 summarizes the set of commands sent over the console for setting the OTAA mode on the RAK4600
Figure 57: RAK4600 LoRa parameters configuration over the Serial Port Tool
8. Command the RAK4600 to join in OTAA mode
at+set_config=lora:dev_eui:d045f054b2797f7c
at+set_config=lora:app_eui:d045f054b2797f7c
at+set_config=lora:app_key:2cb29aefe344c0d7b044e7a7d3afda6d