1. Make sure E1 link Cable Matches connected Equipment
If equipments such as PDH, SDH are used in E1 link which RC series converters are
connected to, please read their usage manuals for the type, definition, and impedance of
E1 interface.
2. Make sure Optical Medium Matches Converter
Optical medium for RC906-FXE1-M should be multi mode and the connector should be
SC/PC.
Optical medium for RC906-FXE1-S1/2/3 should be single mode and the connector should
be SC/PC.
Optical medium of single mode interface of RC916-FXE1-S1 should be single mode and
the connector should be SC/PC.
Optical medium of single mode interface of RC916-FXE1-S2 should be single mode and
the connector should be SC/APC.
3. Confirm the type of optical cable
Cable type that used for multi mode fiber interface:
62.5/125um multi mode fiber or 50/125um multi mode fiber
Cable type that used for single mode fiber interface:
9/125um single mode fiber
4. A conventional application
This device can provide user a 75 ohm unbalanced E1 interface, an optical interface that
can be connected to 100M full-duplex Ethernet and 2048Kbps actual transmission
bandwidth when all of the settings are in default status.
Please refer to chapter 2 when you need to adjust parameters.