background image

                                      

Beijing Raisecom Science & Technology Co., Ltd. 

2. Overview 

2.1. Introduction 

RC513/514 series remote-end managed, bandwidth adjustable Ethernet media 

converters are new generation media converters developed by Raisecom.   

The remote-end management means that the network administrators can manage both 

the host-end and the remote-end equipments to conduct such operations as working 

status review, equipment control, loop-back test, and data flow statistics, etc. 

The bandwidth adjustment means that the administrator can adjust the sending and 

receiving bandwidth of copper ports by N X 32kbps.   

Operations to host-end equipment are as follows:   

1.  Working status review of host-end equipment: 

The working status that can be reviewed is: 

a.  Copper port: upstream link, port ON/OFF, auto-sensing, full/half 

duplex; 

b. 

Fiber port: link receive (RLK), link transmit (TLK), port ON/OFF;   

c.  Others: Fault-pass-through enable/disable, management status of 

remote-end equipment, loop-back test status, loop-back test success report, 

configuration application.   

2.  Configuration of host-end equipment: 

The configurable items include:   

Copper port auto-negotiation, copper port duplex mode, copper port ON/OFF, 

Fault-pass-through enable/disable, remote-end management functions, reset of copper 

and fiber port, loop-back test enable and forbid, sending and receiving bit rate at N x 

32kbps.  

Operations to remote-end equipment are as follows:   

1. 

Working status review of remote-end equipment: 

The working status that can be reviewed is: 

a. 

Copper port:    link up, port ON/OFF, auto-sensing, full/half duplex; 

b. 

Fiber port: link receive (RLK), link transmit (TLK);   

c. 

Others: fault pass through enable, abnormal upper/lower limit of power 

voltage, feedback to configuration application, temperature of chassis 

ambience.  

2. 

Configuration of remote-end equipment: 

The configurable items include:   

Copper port auto-negotiation, copper port duplex mode, copper port ON/OFF, 

Fault-pass-through enable/disable, reset of copper and fiber port, sending and receiving 

bit rate at N*32kbps. 

 

 

 

 
 

3

Summary of Contents for RC513

Page 1: ...RC513 514 FE Rev A 10 100M Auto negotiation Copper to Fiber Media Converter User Manual Raisecom Technology Co Ltd Dec 2005 ...

Page 2: ...URATION RJ45 PORT 9 5 3 1 RC513 514 FE Series RJ45 Interface Auto negotiation 9 5 3 2 RC513 514 FE Series RJ45 in Forced Status 9 5 4 CONNECTION WITH OTHER EQUIPMENT AT OPTICAL PORT 9 6 INSTALLATION INSPECTION 10 6 1 MATCHING FIBER OPTIC CABLE WITH MEDIA CONVERTER 10 6 2 TYPES OF FIBER OPTIC CABLE 10 6 3 RJ45 INTERFACE 10 6 4 INSTALLATION OF CHASSIS FOR RC514 10 6 5 INSTALLATION OF DC POWER SUPPLY...

Page 3: ...d damaging it is not allowed that the optical power of transceiver s output interface is higher than that of RC513 514 FE RC513 514 FE Rev A is an integrated device which has precise elements please avoid violent shake and impact and do not disassemble or maintain the device yourself If it is required please do it under the guide of our technical staff following anti static steps Please contact us...

Page 4: ... management status of remote end equipment loop back test status loop back test success report configuration application 2 Configuration of host end equipment The configurable items include Copper port auto negotiation copper port duplex mode copper port ON OFF Fault pass through enable disable remote end management functions reset of copper and fiber port loop back test enable and forbid sending ...

Page 5: ...RC513 FE S1 Standalone remote managed 10 100Mbps auto sensing single mode single strand dual wavelengths 0 25Km RJ45 SC RC514 FE S1 Module remote managed 10 100Mbps auto sensing single mode single strand dual wavelengths 0 25Km RJ45 SC Note RC514 FE and RC513 FE must be deployed in pairs 4 ...

Page 6: ...RT NUMBER Interface Wavelength nm Launch Power dBmW Receiving Sensitivity dBmW Typical Range Km Attenuation dB Km RC513 FE S1 SC PC RJ45 1310 12 3 30 0 25 0 5 RC513 FE S2 SC PC RJ45 1310 5 0 32 10 50 0 5 RC514 FE S1 SC PC RJ45 1550 12 3 30 0 25 0 5 RC514 FE S2 SC PC RJ45 1550 5 0 32 10 50 0 5 5 ...

Page 7: ...ition OFF and RLK ON Optical transmit link fails Optical Interface Optical Data Active ACT Flashing Transmitting data in Optical interface Remote Management Device RMD ON Remote media converter supports remote SNMP management OFF Remote media converter does not support remote SNMP management Fast flashing host and remote end managed Slow flashing remote end management prohibited by the remote end ...

Page 8: ...g conditions indicated by each indicator are as follows PWR steady ON the power supply of chassis is working in good condition PS1 5V steady OFF the PS1 power supply to modules is in good condition PS1 12V steady OFF the PS1 power supply to the electric fans is in good condition PS2 5V steady OFF the PS2 power supply to modules is in good condition PS2 12V steady OFF the PS2 power supply to the el...

Page 9: ...nt shall be configured to 10 100Mbps auto sensing Media Converter Other Equipment RJ45 UTP Cable Type Media Converter Switch Straight through Crossover Media Converter HUB Straight through Crossover Media Converter Router Crossover Straight through Media Converter Network Interface Card Crossover Straight through 2 When RJ45 interface of RC513 514 series media converters works on the forced status...

Page 10: ...data transmission Media Converter RJ45 Mode Other Equipment RJ45 Mode 100M Full Duplex 100M Full Duplex 100M Half Duplex 100M Half Duplex 10M Full Duplex 10M Full Duplex 10M Half Duplex 10M Half Duplex 5 4 Connection with Other Equipment at Optical Port Several mandatory conditions are required 1 The same wavelength single strand dual wavelength media converters are not included 2 The same bit rat...

Page 11: ...single mode fiber 6 3 RJ45 Interface Cat 5 of twisted pair shall be used Please note that twisted pair cables shall not be longer than 100 meters For connection configuration please see Chapter 2 Connection with Other Equipment at RJ45 Port 6 4 Installation of Chassis for RC514 The chassis can be fixed onto 19 rack The fixing accessories of chassis are in the accessory box If fixing the chassis wi...

Page 12: ...e connectors 48V ground and 0V These three connectors are connected respectively with 48V power cable ground protection and 0V power cable 48V 地 0V 6 6 Ambience Working temperature 20 60 Humidity 5 90 non condensing 6 7 Power Supply Chassis 115 230V AC or 48V DC 6 8 Dimensions Modular 91 width 25 height 155 depth mm 11 ...

Page 13: ...is 10M 2 RJ45 manual 100M 10M setup OFF RJ45 manual setup bit rate is 100M ON RJ45 manual setting Half duplex 3 RJ45 manual setup Full Duplex Half Duplex OFF RJ45 manual setting Full duplex 4 Vacant Reserved ON Over sized frame up to 1536 bytes 5 Over sized frame configuration OFF Over sized frame up to 1916 bytes ON Disable remote network management 6 Remote network management enable disable OFF ...

Page 14: ...tation Only used for RC513 Normal beyond upper limitation Uncontrollable non configurable 10 Module voltage beyond lower limitation Only used for RC513 Normal beyond lower limitation Uncontrollable non configurable 11 Module temperature Only used for RC513 Actual temperature Uncontrollable non configurable 12 RJ45 Link status Up Down Uncontrollable non configurable 13 RJ45 auto negotiation Enable ...

Page 15: ... Loop back The results of test can be shown through Show Module Info 8 4 Show Module Info Reset The host or remote end modules can be reset through Host Module Reset The frame length after the reset is 1 916Bytes and the working mode of port RJ45 is auto negotiation 14 ...

Page 16: ...g Raisecom Science Technology Co Ltd 2005 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification V36 15 ...