background image

 

           

a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, 
energy hazards may still exist. 
Before working on equipment connected to power lines or telecommunication lines, remove jewelry 
or any other metallic object that may come into contact with energized parts. 
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding 
is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth 
lug is provided on the product, it should be connected to the protective earth at all times, by a wire 
with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed 
racks and cabinets. 
Always make the ground connection first and disconnect it last. Do not connect telecommunication 
cables to ungrounded equipment. Make sure that all other cables are disconnected before 
disconnecting the ground. 

Connection of AC Mains 

Make sure that the electrical installation complies with local codes. 
Always connect the AC plug to a wall socket with a protective ground. 
Always connect the power cord first to the equipment and then to the wall socket. If a power switch 
is provided in the equipment, set it to the OFF position. If the power cord cannot be readily 
disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency 
switch is installed in the building installation. 

Connection of DC Mains 

Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to 
the ground. Any single pole can be externally grounded. 
Due to the high current capability of DC mains systems, care should be taken when connecting the 
DC supply to avoid short-circuits and fire hazards. 
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to 
qualified service and maintenance personnel. 
Make sure that the DC supply is electrically isolated from any AC source and that the installation 
complies with the local codes. 
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate 
the circuit breaker of the panel board that services the equipment and switch it to the OFF position. 
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, 
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. 
A readily accessible disconnect device that is suitably rated and approved should be incorporated in 
the building installation. 

Preventing Electrostatic Discharge Damage 

Modules which can be plugged into chassis are sensitive to damage from static electricity. 
Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam 
packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper 
electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. 
To minimize the potential for ESD damage, observe the following guidelines: 
• Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good 
skin contact. 
• When removing or installing a component, make sure the equipment end of your antistatic strap 
leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal 
surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only 
protects the component from ESD voltages on the body; ESD voltages on your clothing can still 
cause component damage. 
• Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a 
static shielding bag. If you are returning the item to the factory, immediately place it in a static 
shielding bag. 
• Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector 
pins. 

Summary of Contents for ISCOM2128EA-MA

Page 1: ...www raisecom com ISCOM2128EA MA REV A User Manual ...

Page 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2011 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Page 3: ...ld Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the ISCOM2128EA MA REV A device works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en contact us html If yo...

Page 4: ...escription 3 3 1 Front panel and explanation 3 3 2 Rear panel and explanation 4 Chapter 4 Installation And Connection 5 4 1 Device models 5 4 2 Device installation 5 4 2 1 Installation environment 5 4 2 2 Install onto the rack 5 4 2 3 Connect to ground 5 4 3 Connection of switch 5 4 3 1 Connect to CONSOLE 5 4 3 2 Connect to Ethernet 7 4 3 3 Connect to power supply 7 4 4 Making cable 7 4 5 Power su...

Page 5: ...Release Notes Date of Release Manual Version Revisions 2011 6 23 201102 First release of REV A ...

Page 6: ...e Organization This manual is an introduction of the main functions of ISCOM2128EA MA To have a quick grasp of the using of ISCOM2128EA MA please read this manual carefully The manual is composed of the following chapters Chapter 1 Overview This chapter briefly introduces the content referred in this manual reference documents and terminology explanations Chapter 2 Dimensions This chapter mainly i...

Page 7: ...the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight at the laser beam The use of optical devices with the equipment will increase eye hazard Use of controls adjustments or performing procedures other than those specified herein may result in hazardous radiation exposure ATTENTION The laser beam may be inv...

Page 8: ...uthorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes Before connecting the DC supply wires ensure that power is removed from the DC circuit Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position When connectin...

Page 9: ...100Mbps based on 4B 5B coding and uses category 5 twisted pair cable 100BASE X Brief terminology of IEEE 802 3 for LANs operates at 100Mbps based on 8B 10B coding and uses optical fiber Auto negotiation Auto Negotiation detects the various modes that exist in the device on the other end of the wire the Link Partner and advertises its own abilities to automatically configure the highest performance...

Page 10: ... Ethernet electrical ports and 4 COMBO ports 4 100 1000M SFP optical ports and 4 100 1000M Ethernet electrical ports the power of system is smaller than 20W 2 2 Dimension of the device Dimension of ISCOM2128EA MA is 44mm H 440mm W 220mm D weighted 3 0kg it can be put on the table 2 3 Working environment Environment temperature 0 45 Storage temperature 25 65 Environment humidity 10 90 without conge...

Page 11: ...ptacle for 220V AC power and number 13 is for DC power Number 5 is the 24 10 100 Ethernet electrical ports being numbered as 1 24 Number 6 is the LNK ACT status indicators for Ethernet electrical ports Number 7 is the 4 100 1000M SFP optical ports being numbered as 25 28 Number 8 is the LNK ACT status indicators for SFP optical ports Number 9 is model of the switch ISCOM 2128EA MA Number 10 is the...

Page 12: ...www raisecom com User Manual 4 3 2 Rear panel and explanation The rear panel of ISCOM2128EA MA as the following figure There is no fan in this device ...

Page 13: ...th sides of ISCOM2128EA MA To maintain ambient airflow there must be some space around the two sides or airflow path The heat exhausting inlets should not be blocked in case that the airflow can not flow 4 2 2 Install onto the rack Install the brackets onto the device and then fix the brackets on rack by the screws to make the device as stable as possible 4 2 3 Connect to ground Please connect the...

Page 14: ...C Signaling and Pinouts of PC serial port Pin No Signal Type Pin No Signal Type 1 DCD 6 DSR 2 RxD In 7 RTS 3 TxD Out 8 CTS 4 DTR 9 RI 5 GND CONSOLE connection and parameters PC serial interface ISCOM2128EA MA CONSOLE Parameters of simulation program on PC terminal are as follows Baud rate 9600 Data bit 8 Stop bit 1 Parity None Flow control None ...

Page 15: ...J45 plug and connector is available in signal definition of CONSOLE port Signaling and Pinouts of MDI and MDIX are in the following table Pin No MDI X signal MDI signal 1 RD TD 2 RD TD 3 TD RD 6 TD RD 4 5 7 8 N C N C The Ethernet ports of ISCOM2128EA MA are MDI X ports when disable auto negotiation and can be connected to PC which has MDI port though straight through cable 4 3 3 Connect to power s...

Page 16: ...alizing After self check and initialization the device starts to operate and then the SYS indicator starts flickering which means that system operates normally Indicator LEDs of the 24 Ethernet ports indicate the status of ports ON or OFF is according to port configuration and connection If the CONSOLE port is connected to PC and terminal software is configured correctly before system powered on t...

Page 17: ...eme moisture may result in short circuit and if too dry there may be fire So there must be a suitable environment for the device The power supply must be grounded to discharge static There must be some space between device and the near electrical equipments We recommend that outside device routing intersect with live wire to avoid long paralleling Follow the guide strictly when installing Do not i...

Page 18: ...Address Building 2 No 28 of the Shangdi 6th Street Haidian District Beijing Postcode 100085 Tel 86 10 82883305 Fax 86 10 82883056 Email export raisecom com http www raisecom com ...