Raisecom ISCOM2109F Hardware Installation User Manual Download Page 6

www.raisecom.com                                                                                                                                     

 User Manual

 

 

2           

be present inside certain products even when the power switch (if installed) is in the OFF position or 
a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, 
energy hazards may still exist. 
Before working on equipment connected to power lines or telecommunication lines, remove jewelry 
or any other metallic object that may come into contact with energized parts. 
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding 
is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth 
lug is provided on the product, it should be connected to the protective earth at all times, by a wire 
with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed 
racks and cabinets. 
Always make the ground connection first and disconnect it last. Do not connect telecommunication 
cables to ungrounded equipment. Make sure that all other cables are disconnected before 
disconnecting the ground. 

Connection of AC Mains 

Make sure that the electrical installation complies with local codes. 
Always connect the AC plug to a wall socket with a protective ground. 
Always connect the power cord first to the equipment and then to the wall socket. If a power switch 
is provided in the equipment, set it to the OFF position. If the power cord cannot be readily 
disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency 
switch is installed in the building installation. 

Connection of DC Mains 

Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to 
the ground. Any single pole can be externally grounded. 
Due to the high current capability of DC mains systems, care should be taken when connecting the 
DC supply to avoid short-circuits and fire hazards. 
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to 
qualified service and maintenance personnel. 
Make sure that the DC supply is electrically isolated from any AC source and that the installation 
complies with the local codes. 
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate 
the circuit breaker of the panel board that services the equipment and switch it to the OFF position. 
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, 
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. 
A readily accessible disconnect device that is suitably rated and approved should be incorporated in 
the building installation. 

Preventing Electrostatic Discharge Damage 

Modules which can be plugged into chassis are sensitive to damage from static electricity. 
Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam 
packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper 
electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. 
To minimize the potential for ESD damage, observe the following guidelines: 
• Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good 
skin contact. 
• When removing or installing a component, make sure the equipment end of your antistatic strap 
leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal 
surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only 
protects the component from ESD voltages on the body; ESD voltages on your clothing can still 
cause component damage. 
• Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a 
static shielding bag. If you are returning the item to the factory, immediately place it in a static 
shielding bag. 
• Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector 
pins. 

Summary of Contents for ISCOM2109F

Page 1: ...www raisecom com ISCOM2109F Hardware Installation User Manual ...

Page 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2007 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Page 3: ...6 10 82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the ISCOM2109F device works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en xcontactus con...

Page 4: ...er 4 Chapter 3 Device Appearance 5 3 1 Device front panel description 5 3 2 Device rear panel description 6 Chapter 4 Installation and Application 7 4 1 Before the installation 7 4 2 Device installation 9 4 2 1 Environment requirement 9 4 2 2 Install the device on to a rack 9 4 2 3 Grounding 9 4 3 The connection of the switch 9 4 3 1 Connect to console 9 4 3 2 Connect to Ethernet 11 4 3 3 Connect ...

Page 5: ...at the fiber optic cable is intact and is connected to the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight at the laser beam The use of optical devices with the equipment will increase eye hazard Use of controls adjustments or performing procedures other than those specified herein may result in hazardous...

Page 6: ...nstalled in a restricted access area i e an area where access is authorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes Before connecting the DC supply wires ensure that power is removed from the DC circuit Locate the circuit breaker of the panel board that servi...

Page 7: ...running at 100Mbps 100BASE X A term in IEEE 802 3 for Gigabit Ethernet over fiber based on 8B 10B coding and running at 1000Mbps Auto Negotiation The auto negotiation procedure is the port at one site adapts its bit rate and duplex mode to the highest level it and the opposite site device both support according to the bit rate and duplex mode adopted by the remote site device that is the connected...

Page 8: ...configured to interface for 1000BASE TX 1000BASE FX or 100BASE FX cards The power consumption of the system is less than 20W 2 2 Device dimension The dimension of ISCOM2109F switch s main structure is 1U Height x 440mm Width x 180mm Depth The device weighs about 6kg and can be either fixed into a 19 inch cabinet or placed on a table 2 3 Device operating environment Environment temperature 10 C 45 ...

Page 9: ...tors SYS and PWR Indicator Color Status Description ON The system is initializing after electrifying Flickering The system is operating in order SYS Green Other Status Software fault ON The system is electrified PWR Green OFF The system is not electrified 8 100BASE FX Ethernet interfaces and their corresponding status indicators There are 2 indicators for an interface LNK and ACT Indicator Color S...

Page 10: ...ce rear panel is shown in the figure below 2 1 In the figure shown above The place where the socket for 220V AC power supply locates The place where the switch for 220V AC power supply locates 2 The location for the socket for 48V DC power supply on the device rear panel is shown in the figure below In the figure shown above The place where the switch for 48V DC power supply locates The place wher...

Page 11: ...0M electrical interface The number for the electrical interface is 9 The interface is in support of AUTO MDI MDIX when the auto negotiation function is enabled and 10 100 1000M self adaptation The panel of SC200 GE T is shown in the figure below 10M 100M LNK ACT 1000M 3 3 1 2 1 10 100 1000M Ethernet electrical interface The status indicators for the Ethernet electrical interface Indicator Color St...

Page 12: ...OFF When the port is in Link Up status it indicates that the port is not connecting to the Ethernet at the rate of 1000Mbps Fit screw used to fix the card on to the switch Sub card SC200 GE S1 Sub card SC200 GE S1 provides 1 1000M optical interface The number of the interface is 9 The optical interface is in support of transmission of 20km The panel of SC200 GE S1 is shown in the figure below LNK ...

Page 13: ...r flow unblocked Please make sure the outlets are not blocked 4 2 2 Install the device on to a rack To set the switch firmly into a rack please fix the installation tray to the switch using the four screws come with the device and fasten the installation handle on to the rack 4 2 3 Grounding To ensure the safety of the device and the operator please make sure that the grounding terminal is well co...

Page 14: ...N C No connection b PC serial port signal definition The pin number and pin function definition of 9 pin serial port connector is shown in the figure and table below Pin Number Function Type Pin Number Function Type 1 CD 6 DSR 2 RxD IN 7 RTS 3 TxD OUT 8 CTS 4 DTR 9 RI 5 GND Ground c CONSOLE interface connecting pattern and parameter setup The connecting of ISCOM2109F CONSOLE interface and PC seria...

Page 15: ...the rear panel of the switch with 48V DC power supply using the provided power supply cable Note that there is a switch for the 48V DC power supply on ISCOM2109F After connecting ISCOM2109F to the power supply please turn on the switch to begin the electrifying of the device 4 4 Electrify the switch After installing the switch following the steps above connect the switch to power supply using the ...

Page 16: ... Manual 12 terminal software is correctly configured the user management interface on which users can operate over the switch will appear on the PC For details please refer to the corresponding software configuration manual ...

Page 17: ...ow humidify may lead to fire alarm In a word the switch must be placed in proper surroundings The power supply of the device should be well earthed to let out the static electricity Please keep some space from other powered devices when installing the switch The cable arrangement of the switch should have all cables be placed across the live wire Long distance close parallel of the cables and the ...

Page 18: ...ress 2nd Floor South Building of Rainbow Plaza No 11 Shangdi Information Road Haidian District Beijing Postcode 100085 Tel 86 10 82883305 Fax 86 10 82883056 Email export raisecom com http www raisecom com ...

Reviews: