Raisecom
Gazelle S1020i-LI (A) User Manual
2 Hardware structure
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
23
Figure 2-10
Ground cable
1
Conducting wire
2
Stripped end (connected to the OT terminal)
3
Insulating sheath
4
OT terminal
Figure 2-11
OT terminal
1
Inner diameter of
soldering lug
2
Inner diameter of
sheath
3
Thickness of soldering lug
Technical specifications
Table 2-19 lists technical specifications of the ground cable.
Table 2-19
Technical specifications of the ground cable
Parameter
Description
Model (recommended)
POL-ground cable-OT-1.5-4/stripped-16AWG-D. The letter
D indicates the length, which can be customized. For
example, the customer requires a 2-m cable, and you can
name it POL-ground cable-OT-1.5-4/stripped-16AWG-2m.
Standard
Comply with the UL standard and meet RoHS requirements.
Conducting wire
Yellow/Green multi-strand copper-core conducting wire
16AWG (1.25 mm
2
)
Electronic wire UL1007 or UL1005 is used.
Stripped end
10 mm long, tinned