background image

 

 
 

 

 

WWW.RAISE3D.COM 

AMERICA · ASIA · EUROPE 

Manual Pro2-400: Jam Remove

 

 

4.2 Follow the instructions below to solve the jam issue in this height.   

 

 

4.3 Check  whether  there  is  no  jam  under  this  height,  if  not,  please  install  the  Filament  Run-out 

Sensor back. 

 

Step5. Remove the Nozzle Lifting System 

 

5.1 Remove the Four socket head screws with 2.5mm hex wrench and take the Nozzle Lifting 

System. 

 

 

 

 

 

 

 

 

 

 

If the jam is inside Extruder, please insert 
the Nozzle Cleaning Kit all the way through 
the Extruder to push the filament inside 
out. 

 

If the jam is located at the entrance of the 
PTFE tubes in Extruder Carrier, please pull 
it out. 

Loose the thumb screw and open the side cover. 
Check whether there has filament stuck inside gears. 
If so, remove the filament from gears with tweezers. 
 

Summary of Contents for Pro2-400

Page 1: ...Kit and take it out from the extruder Compare from outside to see where the jam is located at Step3 Remove the Filament Run out Sensor 3 1 Remove the M3 screw with 2mm hex wrench and take the Filament Run out Sensor off a If the jam is located between Filament Run out Sensor and Extruder please move to Step 2 b If the jam is located between Extruder and Extruder Carrier please move to Step 3 c If ...

Page 2: ...n out Sensor back Step4 Remove the Extruder 4 1 Remove the two M3 screws with 2mm hex wrench at back and take the Cable Cover off Remove the two M4 screws with 2 5mm hex wrench on sides and take the Extruder off If the jam is located at the entrance of extruder please pull it out If the jam is inside Filament Run out Sensor please insert the Nozzle Cleaning Kit all the way through the sensor to pu...

Page 3: ...stem 5 1 Remove the Four socket head screws with 2 5mm hex wrench and take the Nozzle Lifting System If the jam is inside Extruder please insert the Nozzle Cleaning Kit all the way through the Extruder to push the filament inside out If the jam is located at the entrance of the PTFE tubes in Extruder Carrier please pull it out Loose the thumb screw and open the side cover Check whether there has f...

Page 4: ...her than the temperature for the filament stuck inside Remove the fixing screws marked in pictures and take Fan and Hot End off If the jam is located at the entrance of the PTFE tubes in Nozzle Lifting System please pull it out If the jam is inside the PTFE tubes in Nozzle Lifting System please remove Hotend and insert the Nozzle Cleaning Kit all the way through the PTFE tubes in Nozzle Lifting Sy...

Page 5: ... the Silicone Cover Remove the Nozzle with 8mm sleeve with one hand and hold the Heating Block with the other hand with heat resistant gloves on 6 4 Insert the Nozzle Cleaning Kit all the way through the throat tube to push the filament inside out If it is too hard to push please insert the probes of Heating Rod and Thermocoupler into the Heating Block to heat and try again ...

Page 6: ...le Check whether there is a tiny gap between Nozzle and Heating Block 6 6 Install Hot End back Step6 Install Everything Back Please take Manual Pro2 402 Hotend Replacement as reference during installing the Hot End back If the jam issue cannot be fixed with the above steps a new Nozzle may need to be taken into consideration ...

Reviews: