16
US English
User Manual VIVA L USA
**:
Please refer to NFPA guidelines in
USA and CAN/CSA B365-M91 in
Canada.
Ad
jac
en
t w
all
Adjacent wall
C
C
Back wall
Si
de
w
all
Clearances to combustible surfaces
**Rear/Top vent option
Ceiling
**
FLOOR PROTECTOR
See further floor protection requirements at bottom of this label.
Floor protection for
Canada: 30" (76 cm)
from unit to front of floor protector.
Floor protector must be under the pipe and 2"
(5cm) beyond each side for back venting.
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply
with 2020 particulate emission standards using crib wood. 1.1
g/hr, Method 28R
MINIMUM CLEARANCE Rear Vent
A: Side Wall To Unit 21" 22"
B: Back Wall To Unit 12" 11"
C: Corner Wall To Unit 14" 22"
D: Celing Height N/A 22.5"
E: Front Wall - Furnishing 29" 29"
F: Back Wall to Pipe 18" 17"
G: Side Wall to Pipe 27" 28"
H: Corner Wall to Pipe 20" 28"
Écartement minimum Évent arrière
A: Mur latéral - Appareil 21" 22"
B: Mur arriére - Appareil 12" 11"
C: Mur de coin - Appareil 14" 22"
D: Plafond - Lappareil N/A 22.5"
E: Distance meuble devant 29" 29"
F: Paroi arrière de cheminée 18" 17"
G: Paroi arrière de cheminée 27" 28"
"H: Coin mur pour cheminée 20" 28"
FLOOR PROTECTION:
Floor protection must be non-combustible material extending beneath the stove,
and to the front and sides from door opening and to the rear as indicated.
The floor protection is not required to have thermal protection (R=0)
Replace glass with only Rais authorized dealer supplied ceramic glass
** Not Tested - NFPA Guidelines in USA, CAN/CSA B365-M91 in Canada
** Non testé - NFPA Guidelines au USA, CAN/CSA B365-M91 au Canada
La protection de sol doit être au moins de 3/8 inch matériel non combustible placé sous le foyer
s'étendant vers l'avant, les côtés les ouvertures et l'arriére comme induqué.
Manufactured by:
RAIS A/S
Industrivej 20, DK-9900 Frederikshavn, Denmark
Model: VIVA L USA. VIVA L G USA. VIVA L CA USA. VIVA L G CA USA
Solid Fuel Room Heater
Tested to:
UL 1482-2011
ULC S627-00
For Use With Solid Wood Fuel Only
Model
Modéle
Date of manufacture Month
Date of fabrication Mois
Year
Année
Serial no.
N° de série
Report No. # 0138WS017S
Made in Denmark
Fabriqué au Danemark
Front
This wood heater needs periodic inspection and repair for proper operation.
Consult the owner's manual for further information. It is against federal
regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner's manual.
F
E
G
G
2"
8"
8"
24
"
8"
D
A
Corner Installation
Parallel wall Installation
B
** Rear / Top vent option Celing