![RAIS Nexo 100 User Manual Download Page 18](http://html2.mh-extra.com/html/rais/nexo-100/nexo-100_user-manual_3513039018.webp)
18
Material:
Remarks:
Bend Tool:
Established:
Designer: Project manager:
Format:
Approved:
Drawing no.:
Revision:
Project:
Drawing name:
INDUSTRIVEJ 20, 9900 FREDERIKSHAVN, DENMARK
Phone +45 98 47 90 33 - Fax +45 98 47 92 91
E-mail: [email protected] - Homepage: www.rais.dk
Change order
Drawing change: Improvement proposal:
Corrections:
D M Y
ksj
Nexo 1025 Opstilling
26-03-2018
A3
10-6550 Nexo 1025 glasdør afstande
til brændbart UISOLERET røgrør
KSJ
1.8
6-30
0-10
0.2
1°
1000-2000
0.15
0.3
1.2
0-5°
> 400
TILLADTE AFVIGELSER FOR VINKELMÅL
50-120 120-400
0-10°
0.8
400-1000
0.5
120-400
0-20°
0-30°
0.3
10-50
30-120
0.9
0.6
3-6
TILLADTE AFVIGELSER FOR LINIEÆRE MÅL
AFVIGELSE I MM
0.1
0.1
VINKELAFVIGELSE
KORTESTE SIDE
0.5-3
pr. 100 mm
OV
UV
350
10
0
450
10
0
50
50
20
0
200
Nexo 1025 (uden sideglas)
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
Nexo 1025 (med sideglas)
Nexo 1025/1225 afstande til brændbart UISOLERET røgrør
570
29
5
670
29
5
34
1
341
49
1
491
287
499
Brændbart loft
21
0
M
in
40
0
M
in
482
694
Material:
Remarks:
Bend Tool:
Established:
Designer: Project manager:
Format:
Approved:
Drawing no.:
Revision:
Project:
Drawing name:
INDUSTRIVEJ 20, 9900 FREDERIKSHAVN, DENMARK
Phone +45 98 47 90 33 - Fax +45 98 47 92 91
E-mail: [email protected] - Homepage: www.rais.dk
Change order
Drawing change: Improvement proposal:
Corrections:
D M Y
ksj
Nexo 1025 Opstilling
26-03-2018
A3
10-6551 Nexo 1025 glasdør afstande
til brændbart ISOLERET røgrør
KSJ
1.8
6-30
0-10
0.2
1°
1000-2000
0.15
0.3
1.2
0-5°
> 400
TILLADTE AFVIGELSER FOR VINKELMÅL
50-120 120-400
0-10°
0.8
400-1000
0.5
120-400
0-20°
0-30°
0.3
10-50
30-120
0.9
0.6
3-6
TILLADTE AFVIGELSER FOR LINIEÆRE MÅL
AFVIGELSE I MM
0.1
0.1
VINKELAFVIGELSE
KORTESTE SIDE
0.5-3
pr. 100 mm
OV
UV
Nexo 1025/1225 afstande til brændbart ISOLERET røgrør
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
350
50
570
24
5
450
670
50
24
5
50
50
341
34
1
200
20
0
491
49
1
287
499
Brændbart loft
21
0
M
in
40
0
M
in
482
694
Material:
Remarks:
Bend Tool:
Established:
Designer: Project manager:
Format:
Approved:
Drawing no.:
Revision:
Project:
Drawing name:
INDUSTRIVEJ 20, 9900 FREDERIKSHAVN, DENMARK
Phone +45 98 47 90 33 - Fax +45 98 47 92 91
E-mail: [email protected] - Homepage: www.rais.dk
Change order
Drawing change: Improvement proposal:
Corrections:
D M Y
ksj
Nexo 1025 Opstilling
26-03-2018
A3
10-6552 Nexo 1025 glasdør afstande
til brændbart UISOLERET røgrør
NORSK BRANDMUR
KSJ
1.8
6-30
0-10
0.2
1°
1000-2000
0.15
0.3
1.2
0-5°
> 400
TILLADTE AFVIGELSER FOR VINKELMÅL
50-120 120-400
0-10°
0.8
400-1000
0.5
120-400
0-20°
0-30°
0.3
10-50
30-120
0.9
0.6
3-6
TILLADTE AFVIGELSER FOR LINIEÆRE MÅL
AFVIGELSE I MM
0.1
0.1
VINKELAFVIGELSE
KORTESTE SIDE
0.5-3
pr. 100 mm
OV
UV
Nexo 1025/1225 afstande til brændbart UISOLERET røgrør NORSK BRANDMUR
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
150
370
50
24
5
250
470
50
24
5
50
341
50
34
1
50
341
50
34
1
287
287
Brændbart loft
40
0
M
in
21
0
M
in
50
40
0
450
20
0
50
50
50
0
500
482
482
Material:
Remarks:
Bend Tool:
Established:
Designer: Project manager:
Format:
Approved:
Drawing no.:
Revision:
Project:
Drawing name:
INDUSTRIVEJ 20, 9900 FREDERIKSHAVN, DENMARK
Phone +45 98 47 90 33 - Fax +45 98 47 92 91
E-mail: [email protected] - Homepage: www.rais.dk
Change order
Drawing change: Improvement proposal:
Corrections:
D M Y
ksj
Nexo 1025 Opstilling
26-03-2018
A3
10-6553 Nexo 1025 glasdør afstande
til brændbart ISOLERET røgrør
NORSK BRANDMUR
KSJ
1.8
6-30
0-10
0.2
1°
1000-2000
0.15
0.3
1.2
0-5°
> 400
TILLADTE AFVIGELSER FOR VINKELMÅL
50-120 120-400
0-10°
0.8
400-1000
0.5
120-400
0-20°
0-30°
0.3
10-50
30-120
0.9
0.6
3-6
TILLADTE AFVIGELSER FOR LINIEÆRE MÅL
AFVIGELSE I MM
0.1
0.1
VINKELAFVIGELSE
KORTESTE SIDE
0.5-3
pr. 100 mm
OV
UV
Nexo 1025/1225 afstande til brændbart ISOLERET røgrør NORSK BRANDMUR
Nexo 1025 (uden sideglas)
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
Nexo 1025 (med sideglas)
150
370
50
24
5
250
470
50
24
5
50
50
341
34
1
50
341
50
34
1
287
287
Brændbart loft
21
0
M
in
40
0
M
in
50
40
0
20
0
450
50
50
500
50
0
482
482
English
RAIS/
attika
– User manual for Nexo
Normal installation – right-angled
Nexo with side glass Nexo with side glass
Non-insulated flue
insulated flue
Distance to furniture (min.) in mm
800
mm
800
Minimum distance to fire wall.
Section of fire wall to the side
450
450
Section of fire wall in front
200
200
*
where dimensions are not specified, follow the national/local provisions
With side glass with Non-insu-
lated flue. Minimum distance to
fire wall
With side glass with insulated
flue. Minimum distance to fire
wall
With side glass with Non-insu-
lated flue. Minimum distance to
combustible material
With side glass with insulated
flue. Minimum distance to com-
bustible material
Summary of Contents for Nexo 100
Page 12: ...12 250 English RAIS attika User manual for Nexo Chimney Shared flue...
Page 22: ...22 English RAIS attika User manual for Nexo...
Page 29: ...29 4 1 2 3 5 6 7 English RAIS attika User manual for Nexo...
Page 40: ...40 English RAIS attika User manual for Nexo...
Page 41: ...41 English RAIS attika User manual for Nexo Fran ais...
Page 42: ...English RAIS attika User manual for Nexo...
Page 43: ...43 A A B B A B B 220 115 900 983 1025 220 195 110 2 Nexo 100...
Page 44: ...A A B B A B B 1235 1193 115 1110 220 195 110 2 220 Nexo 120...
Page 45: ...45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Nexo 100 120...
Page 46: ...1 2 3 4 5 6 7 9 12 13 14 20 21 22 8 10 11 15 15 17 19 16 18 Nexo 100 120 Med sideglas...
Page 48: ......