Changes to chimney connection
The stove is delivered ready for top outlet, but can be changed to back outlet in the
following way:
Knock out the knock-out plate from the surround.
Remove the top plate, if necessary, smoke deflector
plate and baffle.
Remove the blanking plate (3 x M6 nuts) and seal.
Mount the flue collar on the back side with three
M6x20 cylinder screws and M6 nuts.
Mount the top baffle, smoke deflector plate and top
plate in reverse order.
Sample photos
Fix the blanking plate over the hole in the top – ensure
that the seal is positioned correctly.
Screw everything down with the three M6 nuts.