background image

from the top of the support structure to the ceiling 
above Insert 60 may be no less than 60 
½” (1537mm).  See Fig. 5 on page 5 for support 
structure information. 
 
The face of the support structure should be covered 
with non-combustible materials only.  Simply add the 
height of the support structure to the non-combustible 
material height shown in Fig. 6 on page 5.  For exam-
ple:  If the support structure is 12” (305mm) high, add 
12” (305mm) to the 10 7/8” (276mm) non-combustible 
limit for the lower portion of the enclosure. 
 

CHIMNEY REQUIREMENTS 
 

For proper draft and best performance, the chimney 
should extend at least 15’ (4.6m) and not more than 
35’ (10.6m) above the level of the RAIS Insert 60 
hearth.  The chimney must be properly installed and 
supported in accordance with the chimney manufac-
turer’s instructions. The enclosure is not intended to 
support the entire weight of the chimney.  Support 
components are available from the chimney manufac-
turer.  
 
If possible, an installation with a straight vertical chim-
ney will provide the best draft and will be easiest to 
clean.   
 
If a straight chimney is not possible due to obstruc-
tions, up to four 30° elbows may be used to offset the 
chimney around the obstructions.  The elbows must 
be used in pairs in order to return the chimney to ver-
tical after passing the obstruction.  The first offset 
must be at least 8’ (2.5m) above the Insert 60 hearth.   
 
The Insert 60 Fireplace Insert Enclosure is approved 
for installation in the United States with the following 
chimneys: 

 

The listed chimney and their manufacturers are: 
Metal Fab, Inc.               Model TG 
Security Chimneys 

Model ASHT 

Selkirk Metalbest 

Model Ultra-Temp 

Simpson-Dura-Vent 

Model Dura-Plus (SDP) 

 
In Canada, the Insert 60 Fireplace Insert Enclosure is 
listed for use with any 150mm diameter chimney sys-
tem tested and listed to the High Temperature  
(650°C) Chimney Standard, ULC S-629.   
NOTE: THE ANCHOR/BASE PLATE DIMENSIONS 
MAY NOT BE GREATER THAN 305mm X 305mm. 
 
 

The chimney installation begins with a base plate or an-
chor plate mounted to the top of the Fireplace Insert En-
closure.  Before the base plate is installed on the enclo-
sure top, the flexible stainless steel flue connector 
(provided with the enclosure) that will connect the Insert 
60 to the chimney system must be attached to the base 
plate using the four provided sheet metal fasteners.  See 
Fig. 1.    Next, insert the anchor plate/flex connector as-
sembly down through the hole in the top of the enclosure.  
Use the four provided sheet metal fasteners to secure the 
base/anchor plate to the enclosure top. 
 
Next slide the stainless steel 45° slip connector elbow all 
the way onto the stainless flex connector in preparation 
for installing the Insert 60.  Note:  Do not use the black 
45° elbow that is shipped with the Insert 60. 
 
 
 
  
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

COMBUSTIBLE FRAMING 

The Insert 60 Fireplace Insert Enclosure is designed with 
spacers on the side and back surfaces that prevent the 
enclosure walls from coming in contact with adjacent 
combustible materials that are used for framing around 
the enclosure.  In addition, the top of the enclosure in-
cludes a standoff that prohibits the header for the com-
bustible construction above the enclosure from being in-
stalled too close the heat from the Insert 60, enclosure 
top and chimney.  Under no circumstances should the 
spacers or standoff be modified.  REDUCTIONS TO ANY 
OF THE REQUIRED CLEARANCES MAY RESULT IN 
PROPERTY DAMAGE, BODILY INJURY OR EVEN 
DEATH. 
 

Chimney Base/ 
Anchor Plate 

Sheet Metal 
Fasteners 

Stainless Steel 
Flex Connector 

Stainless Steel 
45° Slip Elbow 

FIG. 1 

Summary of Contents for INSERT 60

Page 1: ...IS A S Industrivej 20 9900 Frederikshavn Denmark TEL 45 98 47 90 33 RAIS Inc 1011 Highway 52 West Portland TN 37148 USA TEL 615 325 1700 INSTALLER Leave this manual with the appliance CONSUMER Retain...

Page 2: ...D FUEL BURNING APPLIANCES OR IN CANADA CSA B365 REFER TO THE RAIS INSERT 60 OPERATING IN STRUCTIONS FOR INFORMATION ON THE PROPER USE AND MAINTENANCE OF THE INSERT 60 FIRE PLACE INSERT REFER TO THE RA...

Page 3: ...us SDP In Canada the Insert 60 Fireplace Insert Enclosure is listed for use with any 150mm diameter chimney sys tem tested and listed to the High Temperature 650 C Chimney Standard ULC S 629 NOTE THE...

Page 4: ...installed can be slid into the rough open ing Make any last adjustments to center the enclosure in the opening and secure in place with at least four nails using the pilot holes provide in the enclosu...

Page 5: ...FIG 5 D F E G H J Combustible Non Combustible Material Limits E 39 3 8 1000mm F 60 3 4 1543mm G 28 3 4 730mm H 24 1 4 616 mm J 25 5 8 651mm K 10 7 8 276mm K Non Combustible Materials Only FIG 5 FIG 6...

Page 6: ...tector strip must be laid under the junction be tween the front of the enclosure and the floor protector to prevent coals or embers from reaching the combustible floor See Fig 7 on page 5 COMBUSTIBLE...

Page 7: ...and should be handled carefully to avoid damage 3 Remove the fireplace insert lining to provide access to the leveling screws Install the Insert 60 into the Fireplace Insert Enclosure 1 Using a helpe...

Page 8: ...8...