N E X O   G A S

GB

UK

All manuals and user guides at all-guides.com

Summary of Contents for attika NEXO 100 GAS

Page 1: ...1 POSITIV N E X O G A S GB UK All manuals and user guides at all guides com...

Page 2: ...G31 50 mbar G30 G31 30 mbar G30 G31 50 mbar 9 1 9 1 9 1 8 4 7 5 8 5 8 7 8 8 8 8 36 27 36 36 28 27 36 16 6 13 4 13 2 16 4 13 2 13 2 AT BG CH CZ DK EE ES FI GB GR HR IE IT LT LV NO PT RO SE SI SK TR DE...

Page 3: ...side glass NEXO 120 G Gas with side glass NEXO 120 Classic Gas without side glass NEXO 120 G Classic Gas with side glass NEXO 140 Gas without side glass NEXO 140 G Gas with side glass NEXO 140 Classi...

Page 4: ...LOCATION OF CHIMNEY TERMINALS 27 HORIZONTAL WALL TERMINAL TYPE C11 28 VERTICAL ROOF TERMINAL C31 29 ASSEMBLY OF SECONDARY BURNER 30 Arrangement of Embers and Logs 31 START UP BATTERIES 36 SETTING UP T...

Page 5: ...m your new stove it is important that you read the manual thoroughly before it is installed and put to use For the purpose of the guarantee and all contact regarding the stove in general it is importa...

Page 6: ...arantee is invalidated in the event of damage due to overfiring damage due to external influences and the use of unsuitable fuels failure to comply with statutory or recommended installation instruc t...

Page 7: ...idth depth height mm 446 398 1025 446 398 1235 446 398 1426 446 398 1601 446 398 1861 Weight kg min depending on model approx 125 approx 140 approx 156 approx 166 approx 190 Efficiency G20 I2H I2E 91...

Page 8: ...egulator Low pressure regulator providing the correct gas pressure may be connected For this reason gas bottles without a regulator must not be connected This stove must only be installed set up and s...

Page 9: ...ct is a heating appliance so the surfaces become very hot and should not be touched during use It is therefore recom mended that you use an approved stove screen to protect chil dren vulnerable adults...

Page 10: ...olation tap and the gas meter Ventilate the room by opening windows and doors do not use electrical appliances in the vicinity of the stove Or operate any electrical switches The gas supply must not b...

Page 11: ...re is in accordance with the local gas supply conditions under which the stove is to be installed You should ensure that the gas supply can supply the required quantity of gas and pressure as describe...

Page 12: ...ove can be connected As this stove has a sealed combustion chamber and a built in plinth there is no need for a floor slab The installation must comply with the Building Regulations Gas Safe ty Instal...

Page 13: ...ated in the following sections with regard to installation risk of fire When you choose where you wish to position your stove you should consider the heat distribution to the other rooms Then you will...

Page 14: ...the stove And remove it 4 Unscrew the outer cover plate at the rear of the stove and move it to the upper sur face of the stove 3 To open the door a 14mm open ended span ner is required to turn the tw...

Page 15: ...l cover plate dismounted 7 If the ceramic logs are fitted remove these 10 The internal cover plate is now fitted to the un derside of the top plate as shown It is vital that this plate fits and seals...

Page 16: ...on must only be carried out by a Gas Safe Registered engineer Conversion kit Use article number 3713595 This set contains 4 new injectors suitable for propane LPG gas The injectors for the secondary b...

Page 17: ...for LPG is marked 27 The injector for the pilot light for natural gas is marked 32 The injector for the main burner for LPG is marked 80 The injector for the main burner for nat ural gas is marked 12...

Page 18: ...gain access to the injectors Do this in the following manner Lift the perforated plate up and out of the stove Loosen the four screws holding the gas unit in place UK Remove the reflector plate All m...

Page 19: ...then unscrew the injector Fit the LPG injector and tighten the lock nut Finally re tighten the coupling Once the gas unit has been dismounted replace the four injectors and adjust the three air intak...

Page 20: ...tor Fit the LPG injector and tighten the lock nut Finally re tighten the coupling Replace the injector for the pilot light by loosening the coupling and carefully pull ing the pipe out Note The small...

Page 21: ...oles in the vertical pipe are now open the small one at the rear and the large one at the front Small hole at the rear Large hole at the front The air intake to the main burner is adjust ed for LPG co...

Page 22: ...it is reassembled using the four screws Replace the perforat ed plate and fully assemble the stove See Section Assembly of secondary burners UK Burner pressure is adjusted according to the gas type on...

Page 23: ...building architect or the local building authorities It must be ensured that flammable objects e g furniture are not positioned closer than the distances stated in the following tables risk of fire No...

Page 24: ...E ma 1 50 300 198 223 Normal installation at right angle With side glass A Furniture distance min 700 mm Distance to flammable material min D rear wall 50 mm E to side to wall 300 mm UK All manuals a...

Page 25: ...INDUSTRIV Phone E mail 10 50 50 4 8 5 3 293 293 Corner installation 45 Without side glass A Furniture distance min 700 mm Distance to flammable material min D rear wall 50 mm UK All manuals and user g...

Page 26: ...rawin INDU P E 150 150 626 7 293 293 Corner installation 45 With side glass A Furniture distance min 700 mm Distance to flammable material min D rear wall 150 mm UK All manuals and user guides at all...

Page 27: ...ing name INDUSTRIVEJ 20 9900 FREDERIKSHAVN DENMARK Phone 45 98 47 90 33 Fax 45 98 47 92 91 E mail info rais dk Homepage www rais dk Corrections D M Y ksj NEXO GAS ikke br ndbar v g 45 01 04 2019 A3 10...

Page 28: ...Grol Pou joulat PGI Joints at vent pipes must be airtight and protected against separation by using locking bands or suitable rivets screws If possible a measuring connection piece should be installed...

Page 29: ...h pipe 300 H From an internal or external corner 600 I Overground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in carp...

Page 30: ...Vertical outlet pipe length V for 100 150 pipe Maximum permissible length H 15M Minimum vertical height of outlet pipe 0 5m vertical length of out let pipe V in metres Maximum length of Horizontal ou...

Page 31: ...o that you can use 130 200 after the adapter Outlet terminal 130 200 Art no USDVC 130 100 150 Art no USDVC 100 Minimum vertical length of outlet pipe 0 5m Flue gas Limiter to 100 150 is to be mounted...

Page 32: ...king through the perforated plate Note that there is a right burner and a left one so it is important that they are posi tioned as shown i e that the side with the extra holes faces the front Front wi...

Page 33: ...And that no glowing material finds its way down under the pilot plate guard The other thermosensor must also be kept free of the ceramic Embers When commissioning or servicing the stove it should be e...

Page 34: ...34 ceramic Logs Log 1 Log 2 Log 3 Log 4 Log 6 Log A Log B UK Log 5 All manuals and user guides at all guides com...

Page 35: ...he holes of the center burner Position the 8 logs as shown Note the two special logs marked A and B have a groove moulded on their undersides that fits on top of the two secondary burners The glow wir...

Page 36: ...36 4 3 5 Log 3 Log 4 Log 5 UK All manuals and user guides at all guides com...

Page 37: ...37 6 A B Log 6 Log A Log B UK All manuals and user guides at all guides com...

Page 38: ...ver uses 4 x AA 1 5 V batteries Remember to replace the battery cover Start up Insertion of Batteries The receiver on the stove and the remote con trol use batteries A set of batteries to be inserted...

Page 39: ...39 The batteries in the receiver must face the directions shown in the illustration The remote control uses 2 x AA 1 5 V batteries UK All manuals and user guides at all guides com...

Page 40: ...onised in the following manner Press and hold down the Reset button until you hear a short beep followed by a long beep Release the button Now you have 20 seconds to press the Down Arrow button on the...

Page 41: ...he pilot light Check the functioning of the main burner 1 Turn on the pilot light 2 Turn on the main burner 3 Check that the cross ignition from the pilot light to the main burner occurs easily and th...

Page 42: ...s the pilot light ignited 5 If the pressure is low check that the gas supply pipes are the correct size 6 If the inlet pressure is too high more than 5 mbar over the gas sup ply must be corrected befo...

Page 43: ...is is because the paintwork and ma terial need to harden but the smell will quickly disappear Ensure there is a lot of ventilation preferably a draught Children and pets should be kept at a safe dista...

Page 44: ...Model number of the handset Press on the and buttons at the same time Now the model number of the handset is dis played NOTE When you press on a deactivated button nothing happens and two horizontal l...

Page 45: ...s is confirmed by pressing the and buttons at the same time or waiting Change between C and F by pressing and holding the and buttons at the same time NOTE When F is selected a twelve hour clock is di...

Page 46: ...ies of flashing lines confirm that the start sequence has commenced Then release the buttons The main gas supply starts as soon as pilot ignition is confirmed The handset automatically goes into Manua...

Page 47: ...eight is then adjusted automatically to reach the temperature set Program mode PROGRAMS 1 and 2 can both be programmed to start or stop at specific times at a set temperature Eco mode The flame height...

Page 48: ...3 Select hour by pressing on the or button 14 This is confirmed by pressing on the button 1 OFF is displayed ALL is displayed briefly and Min utes flashes 15 Select minutes by press ing on the or butt...

Page 49: ...for all days of the week Wait until set up is complete HELP MODE After ignition burner 1 is ignited and burner 2 is in the last setting ON A burner is ignited by pressing the button is displayed OFF...

Page 50: ...50 UK All manuals and user guides at all guides com...

Page 51: ...51 UK All manuals and user guides at all guides com...

Page 52: ...r adjusted 7 Put on the gas supply and check for leaks Check that the burners and pilot unit are in good condition and work 8 Refit the perforated plate 9 Refit embers and ceramic logs 10 Check the fl...

Page 53: ...one using a soft dry cloth or brush only Before each new heating season the chimney and flue gas connection piece should always be checked for blockages Check the stove external ly and internally for...

Page 54: ...Fittings on the underside of the pilot unit can be loosened by means of a 10 mm open ended span ner The thermosensor and pilot burner can be replaced To gain access to the nozzles on the main burner t...

Page 55: ...Fi Box incl cable App based control of the stove 10 0000 060980 Topplate B O Stainless Back Outlet 10 0000 061080 Topplate T O Stainless Top Outlet 10 0000 061170 Top plate NEXO Soapstone B O Back Out...

Page 56: ...56 UK All manuals and user guides at all guides com...

Page 57: ...rting the narrow plug on the Wi Fi lead into the opening marked SI The wide plug on the Wi Fi lead is inserted into the Wi Fi box When connecting the Wi Fi box use the mains adapter connection to elec...

Page 58: ...a home network is available That the name and access code of the home network are correct That the Wi Fi router s SSID key is not hidden That the home network s signal is within range That the Wi Fi...

Page 59: ...urchased as spare parts from your RAIS atti ka dealer See spare part drawings back of the manual xx optional colour code UK Pos Number Article no Description 1 1 10 0000 100490 Glass door 2 1 10 0000...

Page 60: ...xx optional colour code Pos Number Article no Description 1 1 10 0000 100490 Glass door 2 1 10 0000 1005XX Classic Glass door 3 1 10 0000 0601XX Top plate for rear outlet 4 1 10 0000 0602XX Top plate...

Page 61: ...Assembly Left 13 RA10R76 Burner Raised Assembly Right 14 RK10P07 Complete Burner Assembly Natural RK10N07 Complete Burner Assembly LPG 15 RK10 SEAL 05 Burner Seal Set 16 3711213 Grate Assembly 17 RK10...

Page 62: ...30 G31at 50 DE Germany I2ELL G25 at 20 mbar I2E G20 at 20 mbarI 3P 50 G31 at 50 mbar I3B P 50 G30 G31 at 50 DK Denmark I2H G20 at 20 mbar I3B P 30 G30 G31 at 30 mbar EE Estonia I2H G20 at 20 mbar I3B...

Page 63: ...2L G25 at 25 mbar I2EK G25 3 at 25 mbar I3P 50 G31 at 50 mbar I3P 30 G31 at 30 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G31 at 30 mbar NO Norway I2H G20 at 20 mbar I3B P 30 G30 G31 at 30 mbar PL Poland...

Page 64: ...0 89 0 8 Burner Pressure hot mbar 13 2 13 2 16 4 16 6 13 4 Injector Marking 120 Centre 260 Left 260 Right Pilot G30 ZP2 312 31 2 inj Efficiency Class 2 Nox Class 5 Type C11 C31 Gas type City gas G150...

Page 65: ...5 0 225 0 29 0 29 0 29 0 253 Burner Pressure hot mbar 27 27 36 36 36 28 Injector Marking 80 Centre 100 Left 100 Right Pilot G30 ZP2 271 27 1 inj Efficiency Class 2 Nox Class 5 Type C11 C31 This stove...

Page 66: ...66 0 5m V 0 5m 5 4 20 1 2 3 6 839 7 EXAMPLES OF CHIMNEY SOLUTIONS Vertical Roof Terminal Distance V 500mm 12m min Max UK All manuals and user guides at all guides com...

Page 67: ...6 5 Vertical Roof Terminal Renovation kit PT 3 of 3 PT 1 of 3 PT 2 of 3 Flexible flue insert 100 AISI 316Ti If the existing chimney is not completely sound the air inlet must also be lined recommended...

Page 68: ...H Vertical Pitched Roof Terminal Distance H 0 3m Min Max Distance V1 500mm 10m Min Max Distance V2 200mm 10m Min Max Distance V3 500mm 10m Min Max Distance V V1 V2 V3 1 2m 12m Min Max Distance V 2 X H...

Page 69: ...11 4 1 2 3 6 5 4 20 Vertical Roof Terminal with Bend Distance H 0 3m Min Max Distance V1 500mm 10m Min Max Distance V2 500mm 10m Min Max Distance V V1 V2 1m 12m Min Max Distance V 2 X H Min UK All man...

Page 70: ...1 of 3 PT 2 of 3 Flexible flue insert 100 AISI 316Ti Distance V 1m 12m Min Max Existing chimney Flue must be inspected by a qualified technician If the existing chimney is not complete ly sound the a...

Page 71: ...n Max Distance V1 500mm 10m Min Max Distance V2 200mm 10m Min Max Distance V3 500mm 10 m Min Max Distance V V1 V2 V3 1 2m 12m Min Max Distance V 2 X H Min Existing chimney with Bend Renovations kit If...

Page 72: ...72 Vertical Roof Terminal with Back outlet for more information see paragraph Location of chimney terminals UK All manuals and user guides at all guides com...

Page 73: ...73 Horizontal wall Terminal for more information see paragraph Location of chimney terminals UK All manuals and user guides at all guides com...

Page 74: ...74 Snorkel Snorkel Top outlet Back outlet Horizontal wall Terminal for more information see paragraph Location of chimney terminals UK All manuals and user guides at all guides com...

Page 75: ...130 130 Length 500mm 3 US 100 100 100 US 100 130 130 Length 1000mm 4 USKB 100 100 USKB 130 130 Locking band 5 USAB 100 100 USAB 130 130 Protective band UK 1 US 25 100 100 US 25 130 130 Length 250mm Al...

Page 76: ...le length 7 USDV2 100 100 Vertical Terminal USKB 8 USDHCE 10 Horizontal Terminal Eccentric outlet 9 USEB 100 100 USEB 130 130 Fitting strap 10 USMB 100 100 USMB 130 130 Adjustable Wall Strap UK All ma...

Page 77: ...USSR 130 130 Cover 12 USB 45 100 100 USB 45 130 130 45 elbow bend 15 USDPAL 100 100 USDPAL 130 130 Flat roof Cover Aluminium 13 USB 15 100 100 USB 15 130 130 15 elbow bend 16 USDP 100 100 USDP 130 130...

Page 78: ...as a pair 18 USDH 100 100 USDH 130 130 Angular Cover 5 30 21 USMPG 100 100 USMPG 130 130 Wall Cover 19 USLS 100 100 USLS 130 130 Angular Cover 20 45 22 ADAPTOR UNIVERSAL SYSTEM ADAPTOR USA 100 130 USA...

Page 79: ...declared performance in point 8 This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4 Signed for and on behalf of the manufacturer by Henrik...

Page 80: ...025 0 271 278 439 869 1025 NEXO 100 Gas dimensional drawing A A 361 390 440 n30 n134 n187 0 115 853 1025 0 271 278 439 869 1025 A A 361 390 440 n30 n134 n187 0 115 853 1025 0 271 278 439 869 1025 All...

Page 81: ...0 481 488 649 1079 1235 440 n187 n134 n30 0 115 1063 1235 A A 571 390 0 481 488 649 1079 1235 440 n187 n134 n30 0 115 1063 1235 A A 571 390 0 481 488 649 1079 1235 440 n187 n134 n30 0 115 1063 1235 A...

Page 82: ...ional drawing 390 440 n187 n134 n30 0 115 1063 1221 1426 0 481 488 649 1079 1426 390 440 n187 n134 n30 0 481 488 649 1079 1426 390 440 n187 n134 n30 0 481 488 649 1079 1426 All manuals and user guides...

Page 83: ...481 488 649 1079 1601 0 115 1063 1221 1601 n134 n30 n187 390 440 0 481 488 649 1079 1601 0 115 1063 1221 1601 n134 n30 n187 390 440 0 481 488 649 1079 1601 0 115 1063 1221 1601 n134 n30 n187 All manua...

Page 84: ...87 n134 n30 0 481 488 649 1079 1861 0 115 1063 1221 1861 390 440 n187 n134 n30 0 481 488 649 1079 1861 0 115 1063 1221 1861 390 440 n187 n134 n30 0 481 488 649 1079 1861 0 115 1063 1221 1861 All manua...

Page 85: ...1 2 3 4 5 NEXO Gas 100 120 140 160 185 All manuals and user guides at all guides com...

Page 86: ...86 1 2 3 4 5 8 6 9 8 7 10 NEXO G Gas 100 120 140 160 185 All manuals and user guides at all guides com...

Page 87: ...87 All manuals and user guides at all guides com...

Page 88: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch All manuals and user guides at all guides com...