background image

3

INSTALLATION MANUAL

Thank you for choosing your new RAIS or 

ATTIKA product! This installation manu-

al will ensure that your fireplace insert is 

installed correctly and that it will provide 

you with comfort and pleasure for many 

years to come. 

IN GENERAL

It is important to correctly install the fire-

place insert out of consideration for both 

the environment and personal safety. 

The installation of the stove must com-

ply with all local rules and regulations, 

including those that refer to national and

European standards. A certified chimney 

sweeper should be contacted before the 

installation is started.

No unauthorised alterations may be 

made to the fireplace insert.

GENERAL INSTALLATION REQUIRE-

MENTS

Before the fireplace insert may be put to 

use, the installation must be reported to 

your local chimney sweeper.

There must be a plentiful supply of fresh 

air in the installation room to ensure 

good combustion – if required, through 

an Air-System connection. NB: Any me-

chanical air extraction, for example a 

cooker hood, can minimise the supply of 

air. 

The wood-burning stove has an air con-

sumption of at least 18 m3/h.

The floor structure must be able to sup-

port the weight of the wood-burning 

stove and a chimney. If the existing floor 

structure does not meet this require-

ment, suitable measures must be taken 

(e.g. installation of a load distribution 

plate). Seek advice from a building ex-

pert.

If the wood-burning stove is to be in-

stalled on a flammable floor, national

 and 

local regulations must be complied with, 

including for the size of the non-flamma-

ble plate, which must cover the floor in 

front of the wood-burning stove to pro-

tect the floor from any embers that fall 

out of the stove. 

The fireplace insert must be positioned at 

a safe distance from flammable material. 

Due to risk of fire, flammable items (e.g. 

furniture) may not be positioned closer 

to the fireplace insert than the closest 

permitted distance stated in the instal-

lation section. When deciding where to 

install your RAIS/ATTIKA fireplace insert, 

you should think about being able to 

heat other rooms in the home, so you 

get the most out of your new fireplace 

insert.

After receiving your fireplace insert, 

please check it for any defects.

CHIMNEY

The chimney must be tall enough to 

ensure correct draught conditions, 

i.e. -14 to -18 pascal. If the recom-

mended chimney draught cannot 

be achieved, problems from smoke 

escaping from the door may arise 

when lighting the fire. We recommend 

adapting the chimney to suit the flue 

outlet connector. The flue outlet connec-

tor is 150 mm in diameter.

If the draught is excessive, it is recom-

mended that you equip the chimney 

with a regulating damper. If a regulating 

damper is fitted, you must ensure that 

there is a free flow area of at least 20 

cm² at the closed regulating damper. 

Remember that there must be unob-

structed access to the access door on the 

chimney.

INSTALLATION MANUAL

GB

Summary of Contents for attika 600 MAX E-2

Page 1: ...BRUGERVEJLEDNING BEDIENUNGSANLEITUNG USER MANUAL MANUEL D UTILISATEUR BRUKERVEILEDNING BRUKSANVISNING K YTT OHJE GEBRUIKERHANDLEIDING 600 MAX 600 MAX E OSITIV UTLINE EGATIV...

Page 2: ...Drawing name INDUSTRIVEJ 20 9900 FREDERIKSHAVN DENMARK Phone 45 98 47 90 33 Fax 45 98 47 92 91 E mail info rais dk Homepage www rais dk Corrections D M Y pch 600MAX Heat storage 21 11 2019 A3 11 0801...

Page 3: ...the handle 14 Removing the combustion chamber lining 15 External air connection Air System 16 Lubricating hinges 18 Fitting the smoke outlet spigot 19 Fitting the top box 20 Fitting the top plate 21...

Page 4: ...bution plate Seek advice from a building ex pert If the wood burning stove is to be in stalled on a flammable floor national and local regulations must be complied with including for the size of the n...

Page 5: ...th depth height mm 688 X 440 X 1305 688 X 440 X 1305 Combustion chamber W x D x H mm 544 X 255 X 165 544 X 255 X 165 Min uptake pascal 12 12 Weight kg min depending on the model 223 246 Efficiency 76...

Page 6: ...A A B B A A B B 688 221 n 1 6 0 438 560 264 5 437 600 MAX 4 Glass 11 0000 6567 341 152 n 9 8 5 1306 1203 115 n 1 3 5 n 1 6 0 79 n 1 1 0 682 440 434 1123 DIMENSIONAL SKETCHES GB...

Page 7: ...6 A A B B A A B B 221 n 1 6 0 600 MAX 4 Classic 11 0000 6568 688 438 560 437 264 5 n 1 1 0 79 1306 115 1203 n 1 6 0 n 1 3 5 440 434 682 n 9 8 5 152 341 1123 DIMENSIONAL SKETCHES GB...

Page 8: ...d Follow the installation and operating instruction manual Intermittent operation F Veuillez lire et observer les instructions du mode d emploi Foyer dur e de combustion limit e homologu pour chemin e...

Page 9: ...il r ggassamleledning og intervalfyring DE Lesen und befolgen Sie die Bedienungsanleitung Zeitbrandfeuerst tte Nur empfohlene Brennstoffe einsetzen UK Fuel types only recommended Follow the installati...

Page 10: ...o polystyrene blocks 1 which protect the combustion chamber lining in transit These must be removed before starting a fire in the stove The glass is not recyclable The glass must be disposed of along...

Page 11: ...es only apply to the wood burning stove The final choice of Chimney solution may have a larger safety distance to the flammable material The Chimney solution must always be installed in accordance wit...

Page 12: ...LAMMABLE MATERIAL 600MAX 600MAX E Three sided The installation distances applicable to the wood burning stove are shown below Bear in mind that the final choice of chimney may have a different safety...

Page 13: ...12 50 500 1100 321 447 1 1 0 0 770 INSTALLATION DISTANCES Flammable ceiling Safety distances to the flammable ceiling and floor are measured from above and below the door GB...

Page 14: ...13 1 HEIGHT ADJUSTMENT HEIGHT ADJUSTMENT The stove is equipped with four adjustment screws 1 under the stove Use the adjustment screws to ensure the wood burning stove stands level GB...

Page 15: ...2 3 2 FITTING CHANGING THE HANDLE The wood burning stove comes with a tem porary handle 1 To remove it undo the screws 2 The new handle 3 can now be fitted to the stove using the screws 2 FITTING THE...

Page 16: ...ber lining 1 Remove the flue panel 1 by pushing the front up and pulling forward so that the rear end becomes free of the vertical panels The flue panel can now be carefully removed 2 Remove the base...

Page 17: ...ure the flexible hose 3 on the spigot 1 using the hose clamp 2 Fit the spigot on the stove with the four M5 screws 4 Secure the valve 6 on the base plate using the double sided adhesive gasket 7 and f...

Page 18: ...e the cover on the rear of the stove and secure the flexible hose 3 on the spigot 1 using the hose clamp 2 Fit the spigot on the stove with the four M5 screws 4 Secure the valve 6 on the wall using su...

Page 19: ...18 LUBRICATING THE HINGES LUBRICATING THE HINGES LOCK The fireplace must be lubricated regularly using the four moving parts on the lock and hinges see image Use heat resistant oil GB...

Page 20: ...MOKE OUTLET SPIGOT THE SMOKE OUTLET SPIGOT CAN BE TURNED TWO WAYS YOU CAN CHOOSE EITHER WAY Version A uses the three free holes 1 8 Slits 2 M6 Nuts 3 M6 Washers 4 M6X20mm cylinder screws Version B use...

Page 21: ...top box place it on the stove and insert the four M5x20mm spacers one in every corner After positioning the top box adjust the intermediary space to 5 mm then tighten the top box with the four M5x10 c...

Page 22: ...n position and insert the four M5x8 spacers supplied one in every corner Once the top plate is lowered in place over the spacers all four bushings below the top plate must fit over the spacers Adjust...

Page 23: ...2 Virkningsgrad 76 R ggastemperatur 306 C Afstand til bagv g se opstillingsvejledning Afstand til sidev g se opstillingsvejledning Emissioner iht NS 3058 og eller CEN TS 15883 Partikler efter NS 3058...

Page 24: ...tilling mod brandbar v g Afstand til sidev g 500 mm normalopstilling mod brandbar v g Emissioner iht NS 3058 og eller CEN TS 15883 Partikler efter NS 3058 g kg t rstof middelv rdi krav 4 Partikler eft...

Page 25: ...luding units where relevant Energy efficiency 76 Emission of CO 0 09 Emission of OGC 54 mgC Nm3 Emission of NOx 69 mg Nm3 Emission of dust 5 mg Nm3 Test report s No s 300 ELAB 2431 EN covering Rais 60...

Page 26: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch POSITIV OUTLINE NEGATIV...

Reviews: