24
Assessment of Performance Report
1235-CPR-2431
In compliance with
Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March
2011
T3
(the Construction products Regulation or CPR), this Assessment of Performance Report applies to the
construction product
T5
Solid fuel room heater, 600 MAX intended for
residential room heating
placed on the market
under the name or trademark of
Rais A/S
Industrivej 19, DK-9900 Frederikshavn
This Assessment of Performance Report attests that the performance of the above-mentioned construction
product has been assessed in accordance with the harmonised standard
T8
EN 13240:2001 + A2:2004
under AVCP system 3
with regard to the essential characteristics listed below
Essential characteristic
Clause No. - Description
Performance
Level or class, unit(s)
Basis for the assessment of
performance
A.4.7
–
Performance at nominal
heat output
Level or class of performance
–
including units, where relevant
-Energy efficiency 76%
-Emission of CO 0,09%
-Emission of OGC 54 mgC/Nm3*
-Emission of NOx 69 mg/Nm3*
-Emission of dust 5 mg/Nm3*
[Test report(s) No(s).]
300-ELAB-2431-EN covering
Rais 600 Inset appliance
A.4.9
–
Risk of fire
- Clearance to combustible
[Test report(s) No(s).]
300-ELAB-2515-EN covering
600 MAX/E free-standing room
heater
This Assessment of Performance Report covers only the above-mentioned essential characteristic(s). It is not an
exhaustive statement of the performance of the product. The manufacturer is entitled to declare the performance
of other essential characteristics than those mentioned above. This Assessment of Performance Report will remain
applicable as long as neither the harmonised standard, the construction product, nor the AVCP methods are
modified significantly
.
24-8-2020
Senior specialist Jes Sig Andersen
DANISH TECHNOLOGICAL
INSTITUTE
Kongsvangs Alle 29, DK-8000 Aarhus C, Denmark.
CRP NANDO Notified Body #1235
www.ec.europa.eu
Accredited to testing according to ISO/EN 17025 by DANAK, #300
www.danak.dk
Jes Sig Andersen
2020.08.24 09:45:47 +02'00'
ASSESSMENT OF PERFORMANCE