background image

- 26 - 

APPENDIX

 

FULL PVMET-500SUNSPEC MAP 

Start 

Name 

Type 

Units 

S F 

Contents 

Description 

40001 

C_SunSpec_ID 

uint32 

"SunS" 

Well-known value.  Uniquely identifies this as a SunSpec 

Modbus Map 

40003 

C_SunSpec_DID 

uint16 

0x0001 

Well-known value.  Uniquely identifies this as a SunSpec 

Common Model block 

40004 

C_SunSpec_Length 

uint16 

65 

Length of common model block 

40005 

16 

C-Manufacturer 

String(32) 

"Rainwise_Inc" 

Well-known value 

40021 

16 

C-Model 

String(32) 

"PVmet 500" 

Manuf specific value 

40037 

C-Options 

String(16) 

"0" 

Manuf specific value 

40045 

C-Version 

String(16) 

"1" 

Manuf specific value 

40053 

16 

C_Serial Number 

String(32) 

"Serial" 

Manuf specific value 

40069 

C_DeviceAddress 

unint16 

60 

Modbus Id 

40070 

C_SunSpec_DID 

int16 

307 

Start of next Device 

40071 

C_SunSpec_Length 

int16 

11 

Device Model Block Size 

40072 

E_BaseMet_Air Temperature 

int16 

°C 

0.1 

Measured 

Ambient Air Temperature 

40073 

E_BaseMet_Relative Humidity 

int16 

Measured 

Relative Humidity 

40074 

E_BaseMet_Barometric_Pressure 

int16 

Hpa 

Measured 

Barometric Pressure 

40075 

E_BaseMet_Wind_Speed 

int16 

m/s 

Measured 

Wind Speed 

40076 

E_BaseMet_Wind_Direction 

int16 

Degree 

Measured 

Wind Direction 

40077 

E_BaseMet_Rain 

int16 

mm 

Measured 

Rainfall 

40078 

E_BaseMet_Snow 

int16 

mm 

Snowfall since last poll 

40079 

E_BaseMet_PPT_Type 

int16 

mm 

Precipitation Type (WMO 4680 SYNOP code) 

40080 

E_BaseMet_Electric_Field 

int16 

V/m 

Electric Field 

40081 

E_BaseMet_Surface_Wetness 

int16 

k

 

Surface Wetness 

40082 

E_BaseMet_Soil_Moisture 

int16 

Soil Moisture 

40083 

C_SunSpec_DID 

int16 

302 

Well-known value.  Uniquely identifies this as a SunSpec 

Irradiance Model 

40084 

C_Sunspec_Length 

int16 

Variable length model block =(5*n), where n=number of 

sensors blocks 

40085 

E_Irradiance_Global_Horizontal_1 

uint16 

W/m² 

Measured 

Global Horizontal Irradiance 

40086 

E_Irradiance_Plane-of-Array_1 

uint16 

W/m² 

Measured 

Plane-of-Array Irradiance 

40087 

E_Irradiance_Diffuse_1 

uint16 

W/m² 

Diffuse Irradiance 

40088 

E_Irradiance_Direct_1 

uint16 

W/m² 

Direct Irradiance 

40089 

E_Irradiance_Other_1 

uint16 

W/m² 

Measured 

Some other type Irradiance 

40090 

C_SunSpec_DID 

int16 

303 

Well-known value.  Uniquely identifies this as a SunSpec 

Back of Module Temperature Model 

40091 

C_Sunspec_Length 

int16 

Variable length model block =(5*n), where n=number of 

sensors blocks 

40092 

E_BOM_Temp_1 

int16 

°C 

0.1 

Measured 

Back of module temperature 

40093 

E_BOM_Temp_2 

int16 

°C 

0.1 

Measured 

Back of module temperature 

40094 

E_BOM_Temp_3 

int16 

°C 

0.1 

Measured 

Back of module temperature 

40095 

EndOfSunspecBlock 

uint16 

0xFFFF 

End of SunSpec  Block 

40096 

C_Sunspec_Length 

uint16 

Terminate length, zero 

Summary of Contents for PVmet 500 Series

Page 1: ...18 2018 Rev 1 0 Copyright 2018 by RainWise Inc All rights reserved No part of this work may be reproduced in any form except by written permission of the publisher All rights of translation are reserv...

Page 2: ...sensors 7 MOUNTING 8 ELECTRICAL 9 POWER 10 RS 485 10 WIND 11 Mini Aervane 12 Ultrasonic 13 PRECIPITATION 14 RELATIVE HUMIDITY AND TEMPERATURE 14 BACK OF MODULE TEMPERATURE SENSOR 14 SOLAR IRRADIANCE 1...

Page 3: ...IFICATIONS 23 SENSORS 23 Operating Environment 23 Ambient Air Temperature Sensor 23 Relative Humidity 23 Barometric Pressure 23 ELECTRICAL 24 Power 24 RS 485 24 Solar Irradiance input 24 MATERIAL SPEC...

Page 4: ...HER STATION The weather station is typically mounted out of normal reach so the system should be operated at ground level to make sure that all components are working properly prior to installation Op...

Page 5: ...ent and must be kept away from surfaces that can radiate heat after being exposed to sunlight for extended periods of time The recommended distance to a large surface i e the ground cement mounting pa...

Page 6: ...ructions Even at 10x the distance of the height turbulent air can cause inaccurate measurements so it is recommended to use the 10x rule as an absolute minimum SOLAR IRRADIANCE SENSORS Solar irradianc...

Page 7: ...ally For diffuse or ground reflected sensors follow the instructions that come with the sensor Each solar irradiance sensor will come with directions for proper mounting and they should be followed ca...

Page 8: ...7 Figure 7 Mast dimensions in inches millimeters The bottom mast should be mounted as vertical as possible in both X and Y axis Verified with a level Having the mast located close to vertical is impor...

Page 9: ...tions in this manual The enclosure has a built in latch on the right side of the unit To open push in on the latch and pull the cover open This latch securely keeps the enclosure closed if additional...

Page 10: ...g is shielded the shield connection should be connected at the power supply end only The earth connection is critical for protection and noise mitigation The earth connection should be connected to th...

Page 11: ...dance cable for better signal quality A 120 termination resistor is provided on the board and is enabled by placing the provided jumper across the resistor symbol The termination resistor may not be r...

Page 12: ...e 12 Miniaervane connections To install the Miniaervane remove the loosen the cap screw and remove the cap Also remove the cable support plug in the top of the mast Connect the RJ 45 connector to the...

Page 13: ...he mast To wire in the ultrasonic the RJ45 cable can be used to pull the wires for the ultrasonic through the mast section It may be easier to cut the RJ45 connector of off the end of the cable then t...

Page 14: ...le up through the hole under the enclosure The temperature sensor is mounted on a long thin PCB board that has ears for locating it in the proper position within the temperature shield stack Because t...

Page 15: ...e end with wrapped shield The 360 shield spring clamp provides a solid shield connection and a good path for dissipating noise and transients To attach the cable simply press the cable with wrapped sh...

Page 16: ...gainst EMI ESD but due to the low voltage signals from solar irradiance sensors they are highly sensitive Care must be taken to route cabling away from electrically noisy equipment such as power inver...

Page 17: ...oll Rate 100ms SUNSPEC REGISTER MAP The PVmet 500was designed to follow SunSpec models outlined by the SunSpec Alliance Other registers other than SunSpec specified ones are provided for extra feature...

Page 18: ...le BOM temperature sensors and has the following characteristics shown in Table 4 Table 4 SunSpec model 303 back of module temperature Field Type Address Offset Block Offset Size Name Label Value Type...

Page 19: ...ssumes base 1 addressing is being used If the host system uses base 0 addressing decrement the starting register values shown by 1 All registers in the SunSpec Register map are read only Use the Modbu...

Page 20: ...o 255 It is only recommended to change this address if a conflict is anticipated If the address has been modified and is unknown it can be discovered by reading only holding register number 200 at Mod...

Page 21: ...re shown in Table 1 Table 8 Device settings baud rate register Name Type Units Scale Factor Contents R W Description 205 1 Baud Rate uint16 9600 R W Baud Rate 9600 or 19200 The default baud rate is 96...

Page 22: ...Description 215 1 Rainfall Accumulation uint16 mm 0 01 0 R W Accumulation in mm This register continually accrues rainfall and does not reset on reading as does the Sunpsec register for rainfall Rain...

Page 23: ...rature 40 C to 60 C 40 to 140 F Humidity 0 100 Condensing AMBIENT AIR TEMPERATURE SENSOR Range 40 C to 70 C 40 to 158 F Accuracy 0 4 C 0 5 F Thermal Time Constant 30 sec Resolution 0 1 C RELATIVE HUMI...

Page 24: ...h 3 5VDC Input voltage low 0 8VDC Input Hysteresis 0 22VDC Input pullup pulldown current 10 A SOLAR IRRADIANCE INPUT Voltage Input 1 5V Max Input current 0 2nA Common mode voltage 1 65VDC Differential...

Page 25: ...25 ENCLOSURE Body Polypropylene with UV inhibitor Hardware 18 8 Stainless Steel Powder Coated 5052 Aluminum Wire Ingress Foam Rubber...

Page 26: ..._BaseMet_Snow int16 mm 1 Snowfall since last poll 40079 1 E_BaseMet_PPT_Type int16 mm 1 Precipitation Type WMO 4680 SYNOP code 40080 1 E_BaseMet_Electric_Field int16 V m 1 Electric Field 40081 1 E_Bas...

Page 27: ...r 202 1 Irradiance_Plane_of_Array_Sensitivity uint16 V Wm 2 0 01 500 R W Sensitivity setting of solar irradiance sensor 203 1 Irradiance_Other_Sensitivity uint16 V Wm 2 0 01 500 R W Sensitivity settin...

Page 28: ...28 BOTTOM MAST DIMENSIONS...

Page 29: ...sequential damages No other warranty written or oral is authorized by RainWise Inc NOTE This warranty gives you specific legal rights and you may have other rights which vary from state to state Some...