- 26 -
APPENDIX
FULL PVMET-500SUNSPEC MAP
Start
#
Name
Type
Units
S F
Contents
Description
40001
2
C_SunSpec_ID
uint32
-
-
"SunS"
Well-known value. Uniquely identifies this as a SunSpec
Modbus Map
40003
1
C_SunSpec_DID
uint16
-
-
0x0001
Well-known value. Uniquely identifies this as a SunSpec
Common Model block
40004
1
C_SunSpec_Length
uint16
-
-
65
Length of common model block
40005
16
C-Manufacturer
String(32)
-
-
"Rainwise_Inc"
Well-known value
40021
16
C-Model
String(32)
-
-
"PVmet 500"
Manuf specific value
40037
8
C-Options
String(16)
-
-
"0"
Manuf specific value
40045
8
C-Version
String(16)
-
-
"1"
Manuf specific value
40053
16
C_Serial Number
String(32)
-
-
"Serial"
Manuf specific value
40069
1
C_DeviceAddress
unint16
-
-
60
Modbus Id
40070
1
C_SunSpec_DID
int16
-
-
307
Start of next Device
40071
1
C_SunSpec_Length
int16
-
-
11
Device Model Block Size
40072
1
E_BaseMet_Air Temperature
int16
°C
0.1
Measured
Ambient Air Temperature
40073
1
E_BaseMet_Relative Humidity
int16
%
1
Measured
Relative Humidity
40074
1
E_BaseMet_Barometric_Pressure
int16
Hpa
1
Measured
Barometric Pressure
40075
1
E_BaseMet_Wind_Speed
int16
m/s
1
Measured
Wind Speed
40076
1
E_BaseMet_Wind_Direction
int16
Degree
1
Measured
Wind Direction
40077
1
E_BaseMet_Rain
int16
mm
1
Measured
Rainfall
40078
1
E_BaseMet_Snow
int16
mm
1
-
Snowfall since last poll
40079
1
E_BaseMet_PPT_Type
int16
mm
1
-
Precipitation Type (WMO 4680 SYNOP code)
40080
1
E_BaseMet_Electric_Field
int16
V/m
1
-
Electric Field
40081
1
E_BaseMet_Surface_Wetness
int16
k
Ω
1
-
Surface Wetness
40082
1
E_BaseMet_Soil_Moisture
int16
%
1
-
Soil Moisture
40083
1
C_SunSpec_DID
int16
-
-
302
Well-known value. Uniquely identifies this as a SunSpec
Irradiance Model
40084
1
C_Sunspec_Length
int16
-
-
5
Variable length model block =(5*n), where n=number of
sensors blocks
40085
1
E_Irradiance_Global_Horizontal_1
uint16
W/m²
1
Measured
Global Horizontal Irradiance
40086
1
E_Irradiance_Plane-of-Array_1
uint16
W/m²
1
Measured
Plane-of-Array Irradiance
40087
1
E_Irradiance_Diffuse_1
uint16
W/m²
1
-
Diffuse Irradiance
40088
1
E_Irradiance_Direct_1
uint16
W/m²
1
-
Direct Irradiance
40089
1
E_Irradiance_Other_1
uint16
W/m²
1
Measured
Some other type Irradiance
40090
1
C_SunSpec_DID
int16
-
-
303
Well-known value. Uniquely identifies this as a SunSpec
Back of Module Temperature Model
40091
1
C_Sunspec_Length
int16
-
-
3
Variable length model block =(5*n), where n=number of
sensors blocks
40092
1
E_BOM_Temp_1
int16
°C
0.1
Measured
Back of module temperature
40093
1
E_BOM_Temp_2
int16
°C
0.1
Measured
Back of module temperature
40094
1
E_BOM_Temp_3
int16
°C
0.1
Measured
Back of module temperature
40095
1
EndOfSunspecBlock
uint16
-
-
0xFFFF
End of SunSpec Block
40096
1
C_Sunspec_Length
uint16
-
-
0
Terminate length, zero