| 25
SYSTEM
Operating Environment
Temperature:
-40° to 140° F (-40° ~ 60°C)
Dimensions
11”x23”x36” (28 x 58 x 91 cm)
Weight
8.9 lbs (4.04 kg)
Certifications
FCC, CE, IC
Data Cache Capacity
365 Days
Logging Rate
Every 15 minutes (See sensor specification notes for details)
Cellular Transmission Rate
Every 15 minutes
Battery Type:
Non-Spillable 4V 4.5Ah AGM sealed lead-acid 1A peak, 12 mA typical
Battery Life:
2 to 5 Years typical
Cellular Modem Type:
CAT-M / NB-IoT
Solar Panel Type:
mono crystaline 7V 2.3 W
Warranty
2 Years
STATION OPERATING MODES
Standard
Power
Saver
Logging
Hibernate
Recharge
Battery Status
Battery
Charged
Low
Battery
Critically Low
Battery
Critically Low
Battery
Critically Low
Battery
Aspirated Sensor Measurement
Frequency
1 min
2 mins
5 mins
None
None
Cellular Data Transmission
Frequency
15 mins
15 mins
24 hrs
None
None
Panel LED Color
Green
Blue
Red
Red
None
LED Blink Frequency
10 sec
10 sec
10 sec
20 sec
None
S P E C I F I C A T I O N S