15
System Alarms
Your system is equipped with several alarm tones: low salt, no salt, and
service required. Please see below for information on the alarms:
Salt Alarms:
When your system’s salt alarm sounds, you will have the
option of refilling the salt tank now or postponing the alarm until later.
To add salt now, follow the onscreen prompts. To postpone the alarm,
use the
Adjust Up
and
Adjust Down keys
to select the number of days
you wish to postpone the alarm. Press the
Enter key
after the number
of days has been selected.
Service Required Alarms:
Please contact your local RainSoft Dealer
for service.
Understanding the Information
Center
The Information Center provides current alarm information, water
usage, and general information about your system. To access this
information, please follow the directions listed below.
If the display is not lit, press any key to begin. When the display is lit,
press the
Info. Center key
. To view the list of diagnostics, use the
Menu Forward and Menu Back keys
. To exit the Information Center
at any time, press the
Enter key
.
The following items are displayed in the Information Center:
Model Size:
Displays the customer’s model information.
System Status:
Displays the system’s current status, including any
alarm information.
Regeneration Method:
Demand initiate is the only option.
Salt Level:
Displays the current salt level.
Salt Alarm:
Displays the “ON/OFF” condition and the time set to
sound the salt alarm.
Time of Regen:
Displays the hour set for regeneration.
Avg. Water Use:
Displays the average water use of the system in
gallons per day.
Avg. Weekly Salt Used:
Displays the average weekly salt used in
pounds.
Current Flow Rate:
Displays the flow rate through the system when
water is being used in gallons per minute.
Current Water Used:
Displays the current gallon count since the last
regeneration.
Hardness:
Displays the programmed hardness in grains based on the
water analysis.
Iron:
Displays the programmed iron in parts per million based on the
water analysis.
Est. Next Regen =:
Displays the estimated number of days until the
next regeneration.
Vacation Mode:
Displays the “ON/OFF” condition.
Conditioner Installed:
Displays the date of installation.
Filter Installed (if applicable):
Displays the date of installation.
Drinking Water Installed (if applicable):
Displays the date of instal-
lation.
AirMaster Installed (if applicable):
Displays the date of installation.
Web Address:
Displays the RainSoft web address.
For Service Call:
Displays the service phone number.
To exit the Information Center, press the Enter key.
!
Important Note: The Information
Center is a display only mode and
will not allow any changes to the
settings or current service run
data.
!
Important Note: This is a live func-
tion and will count up as the
gallons are used.
!
Important Note: This estimate is
based on water consumption. It
may take 14 days after start up to
provide an accurate estimate.
!
Important Note: The average water
use will be accurate 7 days after
start up.
Helpful Tip: Disabling the alarm is
not required if you add salt before
the selected number of postpone-
ment days.
Please refer to the“Customer
Settings” on page 13 for instruc-
tions on adding salt.
Helpful Tip: To silence the alarms,
press any key.