Installation Location
You may choose not to treat the water spigots that go outside used for irrigation or sprinkler systems. You will have to plan
the job so that you cut in to feed the CBF1 filter AFTER these spigots. Installing the CBF1 filter after the pressure tank on a
well water system is the preferred location. If you intend to install a water softener for soft water or a UV system for
disinfecting the water, these should be installed
after
the CBF1 filter (see Fig 2).
BEFORE YOU BEGIN INSTALLATION
,
CONFIRM THE INLET AND OUTLET OF THE UNIT AND
IDENTIFY THE SERVICE AND BYPASS POSITIONS OF THE VALVE.
The bypass valve is used to isolate the
unit from the plumbing system in order to perform maitenance or repairs on the unit. During normal use the bypass valve
should be in “SERVICE” position and to isolate it, the valve should be turned to “BYPASS” position.
Fig 2