5
Pressure Gauge
The PC115A pump controller features a built-in pressure gauge
located on the right side of the unit. This gauge features measure-
ment units in both PSI and bar. One bar is approximately equal to
atmospheric pressure at sea level. In terms of water pressure, 1 bar
= 14.5037 PSI.
Pressure Gauge (bar)
Pressure (psig)
2.0
29.0 PSI
3.0
43.5 PSI
4.0
58.0 PSI
5.0
72.5 PSI
6.0
87.0 PSI
7.0
101.5 PSI
Automatic Reset Function
When a failure is experienced, the automatic reset function will begin
a series of starts to attempt to restore operation without manual
intervention. For example; the pump has a water failure, after five
minutes of low water it will do a 25 second reset, attempting to prime
the pump. If it is able to prime the pump, the failure will clear and the
pump will resume normal operation. However, if the failure persists,
the system will attempt to reset every 30 minutes for 24 hours. If
unable to reset, the system will require manual intervention for assis-
tance.
5. PERFORMANCE SPECIFICATIONS
• Power supply voltage: (1) 115-125V
• Maximum current: 16A
• Max pump power: 1100W (1½ HP) at (1) 115-125V
• Frequency: 50/60Hz
• Protection class: IP65
• Ambient temperature: 0 /+140°F
• Liquid temperature: 0 /+140°F
•
Max flow rate: 44 GPM
• Adjustable starting pressure: 22-36 PSI
• Max operating pressure: 145 PSI