Close the tap mentioned under step (1). After 10-12 seconds the pump will stop running, but

the power supply LED (POWER) will remain lit. Any malfunctions occurring after 

these operations will be caused by improper priming or failure to prime.

2

1

)

Automatic Reset Function:

2

2

)

Troubleshooting:

1.

Read the pressure indicated by the gauge when the pump is started.

2.

Disconnect the power supply.

3.

Open a tap to discharge the pressure.

4.

Adjust the screw clockwise to increase (or counter-clockwise to decrease) the start pressure.

5.

Supply power to the the controller; if you are not satisfied with the adjustment, repeat th

operations described above until you obtain the desired pressure value.

NOTE:

 The maximum pressure of the pump (closing contact pressure) and the minimum 

start pressure must comply with the values shown in the table under paragraph 5.1 otherwise 

the controller will go into FAILURE mode.

If the device goes into failure mode, the automatic reset function will execute a series of automatic 

starts to attempt to restore operation without any manual intervention via the RESET button.

The system operates as follows: The appliance is in failure mode due to water failure, for example; 

after 

five

 minutes in this condition the system will do a 25-second RESET, attempting to prime the 

pump. If the system is able to prime the pump, the failure will disappear and the pump will be ready 

to operate. However, if the failure persists, the system will do another RESET after 

thirty

 minutes, 

and will continue in this manner systematically every 

thirty

 minutes for 24 hours. If the failure still 

persists after all these attempts, the system will remain in this condition until the problem has been 

resolved by manual intervention or when power is recycled.

closed and that 

there are no leaks.

B)

The electrical connection is incorrect: refer to the instructions in Fig. 2.

C)

Electronic board malfunction: replace the electronic board.

 

A)

The pump is not primed; dry-run protection is active and the FAILURE LED is on: prime

the

 

water pipe and check by pressing the manual start button (RESET).

B)

The pump has shut down: the safety system has stepped in and the FAILURE LED is on.

If you press the manual start button (RESET) and the LED (ON) lights up; if the

pump does not start test

 

the output with another device such as a lamp.

C)

Electronic board malfunction: disconnect the pump from the electrical mains and

reconnect it;

 

the pump should start, if it does not replace the controller.

D)

No power supply: check the electrical connections, the POWER LED must be

illuminated.

E)

The pump delivers insufficient pressure, the safety system has stepped in and the

 corresponding LED (FAILURE) is illuminated: make sure that the pump

 

 pressure corresponds to the pressure value

 

specified in the relevant table in

 

 

section 

1

8

.1. 

20

)

Starting Pressure Adjustment: (P. Start):

The pump controller is factory set to start with a minimum pressure of 21.75 PSI (1.5 bar). This 

pressure can be increased up to 36.25 PSI (2.5 bar) by rotating the screw found at the back of the 

cone-shaped end of the device, (see Fig. 4).

To set the pump start pressure:

2) THE PUMP DOES NOT START:

A) Water loss exceeding 0.8 gpm. Make sure that all the taps along the pipeline are

1) THE PUMP DOES NOT STOP:

Summary of Contents for MHP150A

Page 1: ... MHP75A MHP150A User Manual It is the installer s responsibility to read understand and comply with these instructions ...

Page 2: ...iance Mainly applicable for pumping industrial fluids such as mineral water soft water pure water clean oil and circulation and boosting of other weak chemical industrial mediums Rainwater harvesting systems Greywater systems Water treatment processes Industrial cleaners and dishwashers Water boosting applications Heating and cooling for industrial processes Air conditioning systems Air freshening...

Page 3: ...reliably grounded with a circuit breaker The power cord should be less than 15 feet and approved for the current delivered to this pump Ensure that you have made the correct electrical connections for the pump To avoid burning the seal and damaging the pump never let the pump run without water The fan should turn freely by hand when disconnected from power and water The fan should rotate clockwise...

Page 4: ...ermal protector for damage The pump does not pump properly The head is too high The water level is too low Intake isn t in water No water Leak in inlet or outlet hoses Make sure the head isn t too high Verify the suction head is in water Prime the pump The pump runs but no water Intake is blocked Impeller is corroded Intake isn t in water Pump isn t primed Leak in suction pipe Check suction height...

Page 5: ...15 95 5 43 6 30 1 NPT 4 33 4 25 Ø 33 Ø13 75 5 11 9 29 8 19 Inlet 5 11 MHP75A Inlet is 1 NFPT MHP150A Inlet is 1 5 NFPT 9 Dimensions 10 MHP Pump Curve ...

Page 6: ...As with most pump controllers the system high pressure is based on the pump output The pump start pressure low pressure threshold and start trigger is adjustable through a screw on the back side of the unit Your PC115A pump controller features a built in pressure gauge located on the right side of the unit As with many hydraulic devices this gauge displays pressure in units called bar One bar is a...

Page 7: ...n for automatic start after a failure Power supply LED POWER Pump switch on LED ON Safety system activation LED FAILURE Power supply voltage 1 115 125V Maximum current 16 A Max pump power 1100W 1 25 HP at 1 115 125V Frequency 50 60 Hz Protection class IP 65 Ambient temperature 0 140 F Liquid temperature 0 140 F Max flow rate 44 GPM Adjustable starting pressure 20 35 PSI Max operating pressure 145 ...

Page 8: ... assembled and installed by personnel qualified in accordance with local laws regulations and codes 18 1 Water Connection Fig 1 The PC115A must always be installed with the arrows pointing upward connecting the 1 threaded inlet to the pump s outlet and the 1 threaded outlet to the point of use Use flexible pipes for connection to the water network protecting the appliance form any bending loads an...

Page 9: ...anner systematically every thirty minutes for 24 hours If the failure still persists after all these attempts the system will remain in this condition until the problem has been resolved by manual intervention or when power is recycled closed and that there are no leaks B The electrical connection is incorrect refer to the instructions in Fig 2 C Electronic board malfunction replace the electronic...

Page 10: ...p through the suction side the pressure is well below normal with constant fluctuations The safety system will engage and stop the pump the FAILURE LED will light up Check the seal and connections in the suction pipe 3 THE PUMP KEEPS STARTING AND STOPPING There is a small leak in the delivery pipeline check for any leaking taps or running toilets ...

Page 11: ...34 32 30 28 26 44 42 40 38 36 24 22 20 18 16 14 12 10 8 6 4 2 0 GPM 30 50 40 20 10 0 H ft PC115A Friction Loss ...

Page 12: ... MHP75A MHP150A Pump ...

Reviews: