Troubleshooting

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

Product will not circulate 
through the lines 

Reservoir not attached correctly

Detach and re-attach reservoir ensuring that 
the locking clip is engaged.

Battery power is low 

Replace with charged battery and or 
recharge battery.

Product will not circulate 
through lines and 
device is making a loud 
"screaming" sound

Motor has stalled

Hard reset the device by removing battery and 
gently reinserting battery into device.

Product will not flow out 
of the injection tee

Reservoir not attached correctly or is 
empty 

Detach and re-attach reservoir ensuring that 
the locking clip is engaged.

Ball valve on injection tee is closed

Open ball valve. 

Injection tee tip or tubing is clogged 

Use a pick or compressed air to dislodge clog.

Kinked tubing 

Check tubing for kinks.  If kink is found, cut 
tubing to create fresh new end.

Tubing not pushed all the way into 
push-to-connect fitting on tee or device 

Push tubing into fitting or tee until you hear a 
click.

Product programmed to be injected has 
already been dispensed

Reset dosing amount proceed to next injection 
site.

Wrong setting – may be in purge mode

Press arrows left or right to switch to the 
correct mode.

Product will not flow out 
of the injection tee (with 
high psi recording)

Ball valve on injection tee is closed 

Open ball valve.

Injection tee tip is clogged

Use a pick or compressed air to dislodge clog.

Leaking from injection 
tee handle

Injection tip is loose

Tighten injection tip, ensure set screw is in 
place, and tightened.

Ball valve is loose

Tighten ball valve.

Tubing not inserted properly

Push tubing into fitting until you hear a click.

Tubing has been scored too deeply

Re-cut end or replace tubing segment.

Tubing may have been cut incorrectly

Re-cut end to ensure straight edge, or replace 
tubing segment.

Damaged push-to-connect fitting

Replace push-to-connect fitting.

Fluid leaking from pump 
or inside device

Pump seals are worn out or need 
lubrication

Performance may be improved temporarily 
with lubrication. O-rings should ultimately be 
replaced. Send in for repairs.

Pump damaged  

Send in for repairs.

Tubing on interior push-to-connects has 
been scored too deeply

Carefully open housing and re-cut end by cut-
ting or replace tubing segment.

Tubing not inserted properly on internal 
connections.

Carefully open housing and push tubes in until 
you hear a click.

Continued on next page »

Summary of Contents for Quantum

Page 1: ...Quantum protects trees from deadly pests while doing minimal harm using a variable pressure system and plug less tips It is lightweight accurate and able to work all day www RainbowEcoscience com quan...

Page 2: ...ng The Device Calibrate Injecting With The Device Drilling Injection Sites Injecting Injections Wrap Up Storing Of The Device Quantum General Care Storage Quantum Troubleshooting Quantum Repair Instru...

Page 3: ...Carrying Strap 1 x Reservoir Labels 1 x 10ml Measuring Cylinder Electric Drill Dewalt For Optimal Battery Swapping DBH Tape Proper PPE Safety Glasses NOTE polarized glasses may help with screen legibi...

Page 4: ...traight push to connect fitting on the side of the device 3 Set Up Your New Device 2 Ordering Tech Support 877 272 6747 www RainbowEcoscience com II Starting The Device 1 Insert fully charged battery...

Page 5: ...rrows until screen display changes over to injection mode IV Calibrate 1 Once in purge mode press the up button to switch the device to calibration mode 2 Once in calibration mode insert injection tip...

Page 6: ...ose when you complete the 8th dose you will need to reset the injection amount to 9 ml and proceed to inject the remaining ml proceed to inject the remaining volume refer to resetting injection dose i...

Page 7: ...lace avoid rotating counterclockwise when inserting and removing the tip doing so will loosen the injection tip from the injection handle Open ball valve on injection tee and press start button to inj...

Page 8: ...onger proceed to purging the device pg 6 If you want to continue injecting proceed to resetting injection dose below Power off the device by pressing the power on off button for 5 seconds until device...

Page 9: ...al Care Storage 1 2 Daily Cleaning Thoroughly clean the device with gentle cleanser to remove any chemical residue Rinse out device at the end of each workday with at least 200 mls of water Note When...

Page 10: ...le valve on tank reservoir and male valve on pump inlet Place in a controlled indoor enviroment After Heavy Use Follow all cleaning and lubrication protocols to maximize longetivity of all rubber seal...

Page 11: ...dations Calibrate device at start of day and when changing products Do not let batteries fully drain Charge batteries daily preferably after end of the day and leave charging overnight Do not leave pr...

Page 12: ...osing amount proceed to next injection site Wrong setting may be in purge mode Press arrows left or right to switch to the correct mode Product will not flow out of the injection tee with high psi rec...

Page 13: ...will take longer to inject The product used may affect uptake time More viscous products typically take longer to inject Poor uptake conditions Poor uptake conditions very dry or very wet soils weath...

Page 14: ...sure that the lines are free of kinks or debris Didn t prime the product through device Set device to prime mode and use priming port to run product through the lines until air bubbles have cleared De...

Page 15: ...1 2 Replacing The Priming Port Remove by gently pulling on plug Reinsert by squeezing T shaped end and pushing gently back into place 1 2 Repairing Or Replacing Tubing Disconnect tubing by pushing in...

Page 16: ...ors or shears Quantum Repair Instructions Repairing or Replacing Tubing Continued 1 2 Removing Cut Off Tube From Ball Valve Remove the blue collet push to connect part and then gently pull back the te...

Page 17: ...he injection tee Add pipe sealant to the threads on the ball valve and insert the threads into the injection handle turn clockwise to tighten ball valve until hand tight 4 Insert tubing into the push...

Page 18: ...quality and value If you are ever dissatisfied in any way please contact us so that we can address whatever concern you have Our goal is your complete satisfaction Manual www RainbowEcoscience com qu...