INSTALLATION

1.  Check carton and filter components for damage. If anything is damaged, notify the carrier immediately. 

2.  Wrap one to two turns of Teflon tape around the thread of the pressure gauge. Screw the pressure

gauge into the threaded hole on the tank. 

3.  Filtration equipment should be located as close to the pool/spa as possible. Locate the filter on a flat

concrete slab in a well ventilated area free from flooding. Ensure there is adequate drainage. 

4.  Align the filter so the inlet and outlet are positioned as required. 

Connect the filter inlet to the pump outlet. 

5.  Install electrical controls away from pool equipment 

for access in case of emergency. 

6.  Allow sufficient clearance around and above the filter 

to allow for removal of the top section of the tank. 

7.  To reduce pressure losses, use as few bends, elbows 

and fittings as possible. Select the appropriate pipe

grade as specified by local regulations. 

8.  Use a minimum of 50mm (2 inch) UPVC piping or larger. 

9.  Piping should be independently supported to reduce 

strain on the filter. 

10. Do not use tools to tighten the half unions. 

Hand-tighten only. 

START UP AND OPERATION

Fulflo Cartridge Filter Start Up

The  following  steps  should  be  carried  out  for  the  first  run  of  a  new  season  or  after  the  filter  has  been 

reassembled. 

1.  Ensure the pump is off.  Fill the pump’s hair and lint pot with water and replace the lid. 

2.  Loosen (do not remove) the air release valve on the top of the filter. 

3.  Turn the pump on to circulate water through the system. When a steady amount of water comes 

out through the top of the air release valve, close the air release valve. All the air will have been

purged from inside the filter. 

Normal Operation 

If the pump loses its prime, you will need to follow the procedure set out for the filter start up. See Section 

2.1. 

As the dirt load in the filter increases, the pressure gauge reading will rise. When the value has risen 50kPa, 

you will need to clean the filter. Refer to Maintenance. 

Summary of Contents for P200

Page 1: ...nformation about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment This equipment must be in...

Page 2: ...product unless they are closely supervised at all times To reduce the risk of injury always switch the pump off before attempting to change the position of valves or before attempting to assemble dis...

Page 3: ...HESE INSTRUCTIONS INSTALLATION RECORD Clean Filter Pressure Gauge Reading ____________________________________________________ Filter Model ____________________________________________________________...

Page 4: ...s speci ed by local regulations 8 Use a minimum of 50mm 2 inch UPVC piping or larger 9 Piping should be independently supported to reduce strain on the lter 10 Do not use tools to tighten the half uni...

Page 5: ...solution to remove debris not ushed away during cleaning Speak to your local pool professional or contact Waterco 5 Replace the cartridge s caps and spacer 6 Replace the tank top ensuring the o ring...

Page 6: ...ROUBLE SHOOTING The list below contains the more common problems that can occur with this equipment If you cannot identify the fault from the list below consult Waterco or your local pool professional...

Page 7: ...m 500mm P400 1250mm 615mm 95mm 500mm TC300 1250mm 615mm 95mm 500mm TC400 1250mm 615mm 95mm 500mm TC500 1250mm 615mm 95mm 500mm P200 200 18 58 284 102 240 350 P300 300 27 87 424 152 640 350 P400 400 37...

Reviews: