INSTALLATION
1. Check carton and filter components for damage. If anything is damaged, notify the carrier immediately.
2. Wrap one to two turns of Teflon tape around the thread of the pressure gauge. Screw the pressure
gauge into the threaded hole on the tank.
3. Filtration equipment should be located as close to the pool/spa as possible. Locate the filter on a flat
concrete slab in a well ventilated area free from flooding. Ensure there is adequate drainage.
4. Align the filter so the inlet and outlet are positioned as required.
Connect the filter inlet to the pump outlet.
5. Install electrical controls away from pool equipment
for access in case of emergency.
6. Allow sufficient clearance around and above the filter
to allow for removal of the top section of the tank.
7. To reduce pressure losses, use as few bends, elbows
and fittings as possible. Select the appropriate pipe
grade as specified by local regulations.
8. Use a minimum of 50mm (2 inch) UPVC piping or larger.
9. Piping should be independently supported to reduce
strain on the filter.
10. Do not use tools to tighten the half unions.
Hand-tighten only.
START UP AND OPERATION
Fulflo Cartridge Filter Start Up
The following steps should be carried out for the first run of a new season or after the filter has been
reassembled.
1. Ensure the pump is off. Fill the pump’s hair and lint pot with water and replace the lid.
2. Loosen (do not remove) the air release valve on the top of the filter.
3. Turn the pump on to circulate water through the system. When a steady amount of water comes
out through the top of the air release valve, close the air release valve. All the air will have been
purged from inside the filter.
Normal Operation
If the pump loses its prime, you will need to follow the procedure set out for the filter start up. See Section
2.1.
As the dirt load in the filter increases, the pressure gauge reading will rise. When the value has risen 50kPa,
you will need to clean the filter. Refer to Maintenance.