Appendix A: Flow Meters
Page 245
Flow Limit Violation Examples
Overflow in Controller/Main Line Break
Assume the maximum controller flow rate is 500 GPM. A main
line break occurs while attempting to water station 7. The break
results in a flow of 750 GPM. The following warning message
is displayed, as well as the station number and GPM reading.
Figure 179: Warning, Main Flow
The MV1 in the second line represents the Master Valve #1.
To access the warning report, from the base menu, press
F2=WARNING.
Note: Break between Flow Sensor and First Station.
Assume that a line breaks between the flow sensor and the first
valve. When the break occurs, no watering will take place. The
following entry would be placed in the warning list.
Figure 180: Warning, Unsched Limit
Note: This situation may also be caused by a valve that
fails to close.
WARNING = MAIN FLOW (MV) 5-20-96 11:48
STA = 7, MV1, GPM = 750
WARNING = UNSCHED LIMIT 05/20/96 12:05
GPM = 65