background image

1

2

4

3

5

7

8

6

WR2-48 Wireless Sensor

2

WR2 Components

Controller Interface

Sensor

Battery Cassette and Lithium CR2032 
Battery

Sensor Mounting Bracket Assembly

Mounting Hardware

User’s Manual

Quick Reference Guide

WR2-48 Quick Reference Label

d

b

NOTE

: Tools needed for installation: 

drill, drill bit, and Phillip’s head 
screwdriver.

WR2 Benefits

d

l

All settings are programmed through the 

Controller Interface device

d

l

Large easy to understand icons communicate 

irrigation mode and sensor status

d

l

Sensor LED indicator enables one-person 

setup, reducing installation time

d

l

Battery is easy to install / replace

d

l

Aesthetic appearance - no external 

antennas

d

l

Easy to install, self-levelling sensor bracket 

mounts to flat surfaces or rain gutters

d

l

“Quick Shut Off ” interrupts active 

irrigation cycle during a rain event

d

l

Enhanced antenna array provides 

superior signal reliability that overcomes 

most line of sight obstructions

d

l

Automatically prevents irrigation for 

48-hours following a rainfall event (WR2-
48 model only).

Mounting the 

Controller Interface

Choose a location near the irrigation 
controller / timer.

d

d

CAUTION

: The cable harness is 30 

inches (76.2 cm) long, so before 
mounting the device, ensure the wires 
easily reach the irrigation controller’s 
connection terminals.

d

l

Select a flat surface 
adjacent to the irrigation 
controller.

d

l

For best performance, 
the Controller Interface 
should be installed at 
least five feet (1.5m) 
above the ground.

d

l

It is recommended that 
the Controller Interface 
be installed away from 
sources of electrical interference (such 
as transformers, generators, pumps, fans, 
electrical meter boxes) and metal objects 
to maximize communication range.

d

l

Use the mounting hardware supplied. 
Attach the Controller Interface to the wall.

Summary of Contents for WR2RFC-48

Page 1: ...WR2 48 Wireless Sensor User Manual Manual del usuario...

Page 2: ...Synchronize the Sensor and Controller Interface 5 Programming the Set Points 6 Rainfall Set Point 6 Temperature Set Point Rain Freeze Sensor only 6 Programming Irrigation Modes 6 Saving Resetting and...

Page 3: ...r purchase of the WR2 Wireless Sensor Now in accordance with California Executive Order B 29 15 prohibiting the application of potable water to outdoor landscapes during and within 48 hours after meas...

Page 4: ...tive irrigation cycle during a rain event l l Enhanced antenna array provides superior signal reliability that overcomes most line of sight obstructions l l Automatically prevents irrigation for 48 ho...

Page 5: ...wer to the irrigation controller b b NOTE Ensure the sensor switch on the irrigation controller panel is in the active position Controllers with no sensor inputs with or without pump start master valv...

Page 6: ...nt Select from six 6 set points ranging from 1 8 3mm to 1 2 13mm A set point closer to the top of the icon allows for more precipitation to occur before irrigation is suspended Rainfall Indicator Illu...

Page 7: ...d irrigation mode after 72 hours Note X and trip indicator will be displayed when returning to programmed irrigation mode if set points are satisfied Synchronize the Sensor and Controller Interface Af...

Page 8: ...eft or right arrow on keypad to navigate to the Rainfall Indicator icon 2 WhentheRainfall Indicatoriconflashes pressthe button onthekeypadtoset programmingdetails Eachpressofthebutton adjuststhesetpoi...

Page 9: ...cancel Select the Sensor Location The communication range for the WR2 Wireless Sensor is 700 feet 213 4 meters l l A blinking light on the bottom of the Sensor indicates signal strength for 20 minute...

Page 10: ...ensor in the attachment bracket To insert the Sensor in the attachment bracket you must first remove the Sensor cap Hold the sensor body in one hand gently twist the cap with your other hand Slide the...

Page 11: ...tery life or signal strength After the WR2 Wireless Sensor is in operation A sensor that does not communicate battery life signal strength to the Controller Interface is no longer paired 1 First check...

Page 12: ...Is Declared Manufacturer s Name Manufacturer s Address Equipment Description Equipment Class Model Numbers 2004 10S EC 1999 5 EC EN55014 1 2006 EN55022 2006 EN55014 2 1997 Al 2001 EN61000 4 2 EN61000...

Reviews: