![background image](http://html2.mh-extra.com/html/rain-bird/tbos-ii/tbos-ii_user-manual_3449622015.webp)
14
The data will then be immediately transmitted to the TBOS
TM
and is
totally independent of the programming.
If you select the “OFF“ option, watering will be automati-
cally stopped until switched back on. To restart, perform
the same steps as above and select the “ON“ option.
Saving the general program in the TBOS-II™ field transmitter
The new TBOS-II™ universal field transmitter contains an internal memory that can store up to 3 different programs
(irri names).
You can, for example, create 3 different programs covering specific seasons (Spring/ Summer/ Autumn) and save them
in the field transmitter. This action allows you to save time, as they can be transmitted by a simple click at the time of
your choosing. The program of the control module must be read beforehand.
Select “Program memories“ from the TBOS™ IR welcome
screen and confirm by pressing OK.
Then, choose between two options: “Save“ the data in the field
transmitter or “Restore“ the data.
The “Restore“ function allows you to delete all data
contained in the field transmitter except for the time
and the date. “Restoration“ replaces the program
displayed on the field transmitter. A transmission
must then be made to the control module.
Saving program data on the TBOS-II
TM
control module
The TBOS-II™ has memory for storing another program in addition
to its current program.
Select “Backup TBOS“ from the TBOS™ IR welcome menu and
confirm by pressing OK. The console can send a save instruction
to the TBOS™, which will then make a copy of its current
program in its backup memory.
Then choose “Save“ if you wish to save your program in the internal
memory of the control module. Confirm by pressing OK.
Choose “Manual recall“. Upon receiving this instruction, the TBOS™
immediately replaces its current program with the backup program.