Rain Bird RAIN CLOCK PC-104 Owner'S Manual Download Page 11

10

STEP 6: 

TO INTERRUPT WATERING FOR RAIN

The “AUTO/OFF” button allows the watering and programming to be interrupted
until pressed again. it does not affect the program, but it does prevent power
from going to the valves.

T

   

ROUBLE-

                 

S

   

HOOTING

                 

Sometimes when problems occur they can be easily solved by rechecking some
often overlooked possibilities. So check here before you call your dealer or
contractor. It could save you time and money

IF YOU'RE HAVING THIS PROBLEM:

CHECK FOR THESE THINGS:

Automatic Cycle doesn't turn on and the Manual
Start won’t operate:

-If the display is blank, check the fuse.
-Check the wire connections for improper
wiring or shorts.
-Check the valve and valve solenoid for
proper operation.

Automatic Cycle doesn't operate but the Manual
Start does:

-If the last digit blinks, the timer is in the
Rain Shutoff Mode. Press 'Auto/Off" for
normal operation.

Automatic Cycle doesn't turn off:

-Check the wiring for a short or a cross-
connection.
-This is probably not a timer problem, but
a valve problem. Check the solenoid and
the inside of the valve for obstructions.

Entire Display is blank:

-Check the fuse and transformer

Some of the display won’t appear:

-Circuit problem/replace timer

Entire Display blinks:

-9 volt battery needs replacing and the
timer needs reprogramming.

Last Digit blinks:

-Timer is in Rain Shutdown Mode. Press
"Auto/Off" for normal operation.

Last Two Digits blink:

-Timer is counting down time remaining on
the station currently watering.

Timer gains/loses a few minutes/week:

-Caused by intermittent power fluctuations.
Nothing can be done except to correct
time.

Fuse Blows too often/display goes blank:

-There is a short in the wire between the
timer and valve. Make sure connections
are watertight and no bare wires are ex-
posed.
-Maximum current is being exceeded.
Check amperage draw of solenoid
(especially older models and brass
valves). On pump start models, check
combined amperage draw of pump relay
and valve.

Press

Display will show: The Current Time

Last Digit Blinks

Press “AUTO/OFF” again to return to normal.

AUTO

                 

OFF

i.e. the current time is 8:00 a.m.

Summary of Contents for RAIN CLOCK PC-104

Page 1: ...EM CONTROLLER RAIN CLOCK MODELS PC 104 4 Station PC 106 6 Station PC 104 PS 4 Station with Pump Relay Circuit PC 106 PS 6 Station with Pump Relay Circuit Rain Bird Sales Inc Customer Support Center 69...

Page 2: ...ll struggling with your old sprinkler timer Having a hard time complying with local watering restrictions Upgrading to a new Rain Bird sprinkler timer is easier than you might think New timers are eas...

Page 3: ...front cover of the timer by depressing the bottom tab and lifting as shown in Figure 1 Mounting Mount the timer to a wall using two 10 screws installed at centers 3 13 16 apart at eye level Use plasti...

Page 4: ...ll not have the UL listing or the capacity to run long distances The number of wires needed is determined by the number of valves being wired plus a common wire For example three valves in a grouping...

Page 5: ...e doesn t exceed 650 milliamps Important To avoid pump damage caused during a default schedule wire each unused station terminal to a terminal that is being used This prevents the pump from operating...

Page 6: ...3 Setting d 3 SET CLOCK First Press Adjust the hour with ON OFF OR Display Shows Hour 2 00 pm Example 2 00 PM 1400 Hrs Setting h 14 SET CLOCK First Press Adjust the minutes with ON OFF OR Display Sho...

Page 7: ...ock can water either on A specific days of the week or B an interval or cycle of days i e every third day every fourth day etc 2 A Watering on specific days of the week SET CLOCK Press Then turn on of...

Page 8: ...ay other day 4th day 5th day and 6th day see reference chart 2 below First Press Adjust the day showing to ON by holding Display changes to WATER DAYS To return to a 7 day cycle ON for 2 seconds All d...

Page 9: ...Start Time Watering will start at 8 00 AM WATER TIMES PER DAY Press Adjust Start Time 3 with ON Display shows OFF OR i e 6 00 PM 3 C Watering Three Times Per Day 3 D To remove a Start Time WATER TIME...

Page 10: ...at adjustments STATION TIMING Press Adjust the time to 00 ON Display will show OFF OR 4 B To skip a station STATION TIMING Press Press Set Clock to return to the normal time of day display After progr...

Page 11: ...ss connection This is probably not a timer problem but a valve problem Check the solenoid and the inside of the valve for obstructions Entire Display is blank Check the fuse and transformer Some of th...

Page 12: ...t the entire program is lost and the entire display will blink after power is restored The timer is now operating in the default mode eight hours after the power came back on each station will water f...

Page 13: ...ence will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equip ment off and on the user is enc...

Reviews: