10
STEP 6:
TO INTERRUPT WATERING FOR RAIN
The “AUTO/OFF” button allows the watering and programming to be interrupted
until pressed again. it does not affect the program, but it does prevent power
from going to the valves.
T
ROUBLE-
S
HOOTING
Sometimes when problems occur they can be easily solved by rechecking some
often overlooked possibilities. So check here before you call your dealer or
contractor. It could save you time and money
IF YOU'RE HAVING THIS PROBLEM:
CHECK FOR THESE THINGS:
Automatic Cycle doesn't turn on and the Manual
Start won’t operate:
-If the display is blank, check the fuse.
-Check the wire connections for improper
wiring or shorts.
-Check the valve and valve solenoid for
proper operation.
Automatic Cycle doesn't operate but the Manual
Start does:
-If the last digit blinks, the timer is in the
Rain Shutoff Mode. Press 'Auto/Off" for
normal operation.
Automatic Cycle doesn't turn off:
-Check the wiring for a short or a cross-
connection.
-This is probably not a timer problem, but
a valve problem. Check the solenoid and
the inside of the valve for obstructions.
Entire Display is blank:
-Check the fuse and transformer
Some of the display won’t appear:
-Circuit problem/replace timer
Entire Display blinks:
-9 volt battery needs replacing and the
timer needs reprogramming.
Last Digit blinks:
-Timer is in Rain Shutdown Mode. Press
"Auto/Off" for normal operation.
Last Two Digits blink:
-Timer is counting down time remaining on
the station currently watering.
Timer gains/loses a few minutes/week:
-Caused by intermittent power fluctuations.
Nothing can be done except to correct
time.
Fuse Blows too often/display goes blank:
-There is a short in the wire between the
timer and valve. Make sure connections
are watertight and no bare wires are ex-
posed.
-Maximum current is being exceeded.
Check amperage draw of solenoid
(especially older models and brass
valves). On pump start models, check
combined amperage draw of pump relay
and valve.
Press
Display will show: The Current Time
Last Digit Blinks
Press “AUTO/OFF” again to return to normal.
AUTO
OFF
i.e. the current time is 8:00 a.m.