Rain Bird IC System Design Manual Download Page 12

 

12 

IC System

TM

 Design Guide, v2.3 

 

If an individual branch exceeds 25% of the total Trunk wire length, that branch shall be designed with 

the same gauge wire as the Trunk wire. Other branches less than 25% can be designed with a wire size 

no more than 1 size smaller than the Trunk wire size. 

Wire Sizing Charts – (last updated April 2013) 

Number

of

Units

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

11000

12000

13000

14000

15000

50 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

100 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

150 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

200 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

250 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

300 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

350 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

400 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

450 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

500 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

550 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

600 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

10 AWG

650 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

-

-

700 14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

-

-

-

750 14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

10 AWG

-

-

-

April 2013

Wire distance in feet

 

Number

of

Units

1000

1250

1500

1750

2000

2250

2500

2750

3000

3250

3500

3750

4000

4250

4500

50 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2

100 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2

150 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2

200 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2

250 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2

300 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2

350 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2

400 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2

450 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2

500 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2

550 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 6.0mm^2

600 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 6.0mm^2 6.0mm^2

650 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 6.0mm^2 6.0mm^2 6.0mm^2 6.0mm^2

700 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 6.0mm^2 6.0mm^2 6.0mm^2 6.0mm^2

-

           

750 2.5mm^2 2.5mm^2 2.5mm^2 2.5mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 4.0mm^2 6.0mm^2 6.0mm^2 6.0mm^2 6.0mm^2

-

           

-

           

April 2013

Wire distance in meters

 

Initial Length of Run from Interface to First ICM 

In addition to the above wire sizing chart, if the chart recommends 14 AWG (2.5 mm

2

) wire path and the 

initial  run  of  wire  between  the  Interface  and  the  first  ICM  on  the  wire  path  is  greater  than  2,500  feet 

(750m)  then  the  initial  length  of  wire  (from  interface  to  the  first  ICM)  should  be  upsized  by  one 

additional  wire  size  to  12  AWG  (4.0mm

2

).  This  is  only  necessary  when  14  AWG  (2.5  mm

2

)  is  the 

recommended  wire  size.  If  the  chart  recommends  12  AWG  (4.0  mm

2

)  based  on  number  of  units  and 

total length of run of the wire path, then additional upsizing in a long initial run of wire is not necessary. 

 

Summary of Contents for IC System

Page 1: ...IC SystemTM Design Guide v 2 3 Updated August 2016...

Page 2: ...of the IC Interface ICI 6 Uninterruptable Power Supply UPS 7 How the System Works 8 Basic Design Data 9 System Capacity 10 Flexible Design 10 Wire Path 11 Wire Sizing Charts 12 Examples 13 15 Groundin...

Page 3: ...the proper design for the specific application IC System Product Definitions Central Control Software CirrusTM Nimbus IITM Stratus IITM and Stratus LTTM are the Central Control applications that are a...

Page 4: ...nterface ICI is the electronic hardware and firmware that accepts commands from the Central Control Software and directs them to the field The ICI also communicates intelligently with the field in ord...

Page 5: ...ware via Rain Bird MAXITM cable two wire path and the ICI interface The central control software automatically operates the rotors and valves throughout the golf course by activating each individual I...

Page 6: ...PU Board The CPU Board provides communication between the Central Control Computer and each of the wire paths Driver Board The Driver Board provides communication between the CPU board and the ICMs in...

Page 7: ...r the IC System Different countries may have differing requirements and APC typically makes a Smart UPS for each country according to the needs of that country If sourcing a Smart UPS for a different...

Page 8: ...ed Long Address The user must enter the Long Address into the central control software at initial start up The central control software communicates with the ICMs in the field through a high speed met...

Page 9: ...has a maximum capacity of two 2 wire path inputs 4 A single Driver Board has a maximum capacity of 1 500 stations when both wire paths are used 5 The ICI has a maximum capacity of 3 000 stations when...

Page 10: ...h 12 ICIs Standard configuration is number of stations and ICIs available in the software without purchasing a Hybrid Software Module ICIs are purchased separately as needed and are not included with...

Page 11: ...provide the proper guidelines for wire sizing on the wire path The most important calculation is that of the primary Trunk wire length on each wire path The Trunk wire length is considered to be the l...

Page 12: ...2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 100 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 150 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm...

Page 13: ...l be up to 10 000 feet 3 000 meters Utilizing the sizing chart the Trunk wire should use 14 AWG 2 5 mm2 MAXITM wire for the installation Although there are multiple branches off of the main Trunk wire...

Page 14: ...rt the Trunk wire should be designed using 12 AWG 4 0 mm2 wire NOTE 12 AWG 4 0 mm2 wire will be used for the Trunk wire only 14 AWG 2 5 mm2 wire can be used for all branch lines as long as each branch...

Page 15: ...MAXITM wire for the installation As the initial 3 500 feet 1 067 meters is greater than 2 500 feet it requires an increase in wire size to 12 AWG 4 0mm2 The initial 3 500 feet 1 067 meters of Trunk wi...

Page 16: ...there are no ICMs an ICSD is not required every 500 feet 150 meters For example if there is a wire length run of 2 000 feet 609 meters between ICMs an ISCD should be installed immediately after the l...

Page 17: ...vide a good earth ground at the ICSD A measurement with the shield connected does not give a true reading of the individual ground location at the ICSD and will give a reading that is considerably low...

Page 18: ...oting will be more difficult so looping is not recommended Combining Wire Paths at the Interface While a single IC wire path can easily handle 750 ICMs when sized according to the design guide table t...

Page 19: ...communication between the central control computer and the remotely located ICI The MRLK900 Kit includes two radios that operate in the 902 928MHz range and automatically hop between frequencies to av...

Page 20: ...20 IC SystemTM Design Guide v2 3...

Page 21: ...IC SystemTM Design Guide v2 3 21...

Reviews: