background image

Rain Bird 

Flow Sensors 

Manual

 

 

 

 

CALIBRATION TABLE FOR PIPE SIZES 3” THROUGH 36”

 

Column 1 

Column 2 

Column 3 

Column 4 

Column 5 

Column 6 

 

 

 

 

 

Suggested Operating 

Pipe Size 

Pipe O.D. 

Pipe I.D. 

K Value 

Offset 

Range (GPM) 

14" Sch 10S 

14.00" 

13.500" 

122.307 

0.391 

200-6,000 

Sch 20 

14.00" 

13.375" 

120.216 

0.388 

200-6,000 

Std. Wt., Sch 30 

14.00" 

13.250" 

118.151 

0.385 

200-6,000 

Sch 40 

14.00" 

13.124" 

116.096 

0.382 

200-6,000 

Sch 60 

14.00" 

12.814" 

111.148 

0.376 

200-6,000 

Extra Strong 

14.00" 

13.00" 

114.098 

0.33 

200-6,000 

Sch 80 

14.00" 

12.50" 

106.299 

0.369 

200-6,000 

16" Sch 10S 

16.00" 

15.500" 

159.243 

0.44 

300-9,000 

Sch 20 

16.00" 

15.375" 

156.742 

0.436 

300-9,000 

Std. Wt., Sch 30 

16.00" 

15.250" 

154.267 

0.433 

300-9,000 

Sch 60 

16.00" 

14.688" 

143.456 

0.419 

300-9,000 

Extra Strong, Sch 40 

16.00" 

15.000" 

149.394 

0.427 

300-9,000 

Sch 80 

16.00" 

14.314" 

136.548 

0.41 

300-9,000 

18" Sch 10S 

18.00" 

17.500" 

202.739 

0.498 

350-10,000 

Sch 20 

18.00" 

17.375" 

199.828 

0.494 

350-10,000 

Sch 30 

18.00" 

17.124" 

194.061 

0.486 

350-10,000 

Std. Wt. 

18.00" 

17.250" 

196.943 

0.49 

350-10,000 

Sch 40 

18.00" 

16.876" 

188.464 

0.479 

350-10,000 

Sch 60 

18.00" 

16.500" 

180.171 

0.469 

350-10,000 

Extra Strong 

18.00" 

17.000" 

191.25 

0.482 

350-10,000 

Sch 80 

18.00" 

16.126" 

172.152 

0.457 

350-10,000 

20" Std. Wt., Sch 20 

20.00" 

19.25" 

246.179 

0.555 

400-12,000 

Sch 40 

20.00" 

18.812" 

234.836 

0.540 

400-12,000 

Extra Strong, Sch 30 

20.00" 

19.000" 

239.666 

0.547 

400-12,000 

Sch 80 

20.00" 

17.938" 

213.14 

0.511 

400-12,000 

22" Std. Wt., Sch 20 

22.00" 

21.25" 

301.975 

0.621 

500-15,000 

Extra Strong, Sch 30 

22.00" 

21.00" 

294.642 

0.616 

500-15,000 

Sch 80 

22.00" 

19.75" 

259.513 

0.573 

500-15,000 

24" Std. Wt., Sch 20 

24.00" 

23.25" 

364.331 

0.666 

600-18,000 

Extra Strong 

24.00" 

23.00" 

356.178 

0.660 

600-18,000 

Sch 40 

24.00" 

22.624" 

344.109 

0.652 

600-18,000 

Sch 80 

24.00" 

21.562" 

311.271 

0.628 

600-18,000 

26" Sch 10 

26.00" 

25.376" 

437.809 

0.719 

700-21,000 

Std. Wt. 

26.00" 

25.25" 

433.247 

0.716 

700-21,000 

Sch 20, Extra Strong 

26.00" 

25.00" 

424.274 

0.709 

700-21,000 

28" Sch 10 

28.00" 

27.376" 

513.698 

0.774 

900-23,000 

Std. Wt. 

28.00" 

27.25" 

508.723 

0.770 

900-23,000 

Extra Strong, Sch 20 

28.00" 

27.00" 

498.930 

0.763 

900-23,000 

30" Sch 10 

30.00" 

29.376" 

596.147 

0.833 

1,000-30,000 

Std. Wt. 

30.00" 

29.25" 

590.759 

0.829 

1,000-30,000 

Sch 20, Extra Strong 

30.00" 

29.00" 

580.146 

0.822 

1,000-30,000 

32" Sch 10 

32.00" 

31.376" 

685.156 

0.897 

1,200-35,000 

Std. Wt. 

32.00" 

31.25" 

679.355 

0.893 

1,200-35,000 

Sch 20, Extra Strong 

32.00" 

31.00" 

667.922 

0.885 

1,200-35,000 

Sch 40 

32.00" 

30.624" 

650.919 

0.873 

1,200-35,000 

34" Sch 10 

34.00" 

33.312" 

777.566 

0.964 

1,300-40,000 

Std. Wt. 

34.00" 

33.25" 

774.511 

0.962 

1,300-40,000 

Extra Strong, Sch 20 

34.00" 

33.00" 

762.258 

0.953 

1,300-40,000 

Sch 40 

34.00" 

32.624" 

744.022 

0.940 

1,300-40,000 

36" Sch 10 

36.00" 

35.376" 

882.855 

1.040 

1,500-45,000 

Std. Wt. 

36.00" 

35.25" 

876.227 

1.035 

1,500-45,000 

Sch 20, Extra Strong 

36.00" 

35.00" 

863.154 

1.025 

1,500-45,000 

Sch 40 

36.00" 

34.50" 

837.315 

1.007 

1,500-45,000 

Summary of Contents for FS200B

Page 1: ...wept impeller shape provides higher more constant torque than other impeller designs and is less prone to fouling by water borne debris The forward curved shape coupled with the absence of magnetic dr...

Page 2: ...nics package inserted into a proprietary cast bronze pipe tee with threaded NPT female iron pipe thread FIPT connections They are available in the following sizes and thread types Model Thread Size FS...

Page 3: ...ertical pipes 3 Small pipe PVC and Bronze Tee Type sensors are Factory Set but for insert sensors the Insertion depth should be set to 1 1 2 for accurate flow readings The following pages show methods...

Page 4: ...tlet tee the inside dimension of the tee is not the same as the pipe O D Install the 2 NPT adapter provided using a thread sealant to prevent leakage Tighten as necessary Rain Bird insert style sensor...

Page 5: ...n data transmission to connect the sensor to the transmitter monitor or controller 3 Make a water tight splice Direct burial silicone grease splices are recommended Rain Bird DBRY20 or 3M DBR Y 6 Two...

Page 6: ...000 5 4 to 54 20 to 200 1 2 to 12 FS075P 3 4 PVC Tee Flow Sensor 0 1563 0 9000 3 3 to 33 13 to 125 75 to 7 5 FS050P 1 2 PVC Tee Flow Sensor 0 0780 0 9000 1 9 to 19 7 to 70 43 to 4 3 Description of Col...

Page 7: ...80 2 500 Sch 20 8 625 8 125 41 653 0 283 80 2 500 Sch 30 8 625 8 071 41 063 0 283 80 2 500 Std Wt Sch 40 8 625 7 981 40 086 0 281 80 2 500 Sch 60 8 625 7 813 38 288 0 279 80 2 500 Extra Strong Sch 80...

Page 8: ...h 30 20 00 19 000 239 666 0 547 400 12 000 Sch 80 20 00 17 938 213 14 0 511 400 12 000 22 Std Wt Sch 20 22 00 21 25 301 975 0 621 500 15 000 Extra Strong Sch 30 22 00 21 00 294 642 0 616 500 15 000 Sc...

Page 9: ...necessary 7 Refer to Figure 3 To reinstall position the impeller in the cavity oriented as in Step 4 so that the impeller blades point into the flow direction and toward the small alignment hole locat...

Page 10: ...7 VDC in a No Flow situation or less than 3 VDC in a flow situation disconnect the sensor from the barrier strip and measure the voltage at the sensor input terminals of the barrier strip again It sh...

Page 11: ...r recommended design flow range for FS100B Linearity 0 2 of full scale over recommended design flow range 0 7 of full scale over recommended design flow range for FS100B Transducer Excitation Typicall...

Reviews: