CALIBRATION TABLE FOR PIPE SIZES 3” THROUGH 36”

 

Column 1 

Column 2 

Column 3 

Column 4 

Column 5 

Column 6 

 

 

 

 

 

Suggested Operating 

Pipe Size 

Pipe O.D. 

Pipe I.D. 

K Value 

Offset 

Range (GPM) 

3" Sch 10S 

3.500" 

3.260" 

5.009 

.090 

12-400 

Std. Wt., Sch 40 

3.5" 

3.068" 

4.362 

.063 

12-400 

Extra Strong, Sch 80 

3.5" 

2.900" 

3.858 

.043 

12-400 

PVC Class 125 

3.5" 

3.284" 

5.094 

.093 

12-400 

PVC Class 160 

3.5" 

3.230" 

4.902 

.085 

12-400 

PVC Class 200 

3.5" 

3.166" 

4.682 

.076 

12-400 

4" Sch 10S 

4.5" 

4.260" 

9.597 

.241 

20-600 

Std. Wt., Sch 40 

4.5" 

4.026" 

8.34 

.229 

20-600 

Extra Strong, Sch 80 

4.5" 

3.826" 

7.354 

.188 

20-600 

PVC Class 125 

4.5" 

4.224" 

9.396 

.240 

20-600 

PVC Class 160 

4.5" 

4.154" 

9.013 

.240 

20-600 

PVC Class 200 

4.5" 

4.072" 

8.578 

.239 

20-600 

5" Sch 10S 

5.563" 

5.295" 

16.305 

.250 

30-900 

Std. Wt., Sch 40 

5.50" 

5.047" 

14.674 

.248 

30-900 

Extra Strong, Sch 80 

5.50" 

4.813" 

13.165 

.246 

30-900 

6" Sch 10S 

6.625" 

6.357" 

24.089 

.260 

50-1,500 

Std. Wt., Sch 40 

6.5" 

6.065" 

21.574 

.257 

50-1,500 

Extra Strong, Sch 80 

6.5" 

5.761" 

19.457 

.254 

50-1,500 

PVC Class 125 

6.625" 

6.217" 

22.853 

.258 

50-1,500 

PVC Class 160 

6.625" 

6.115" 

21.968 

.257 

50-1,500 

PVC Class 200 

6.625" 

5.993" 

21.068 

.256 

50-1,500 

8" Sch 10S 

8.625" 

8.329" 

43.914 

0.286 

80-2,500 

Sch 20 

8.625" 

8.125" 

41.653 

0.283 

80-2,500 

Sch 30 

8.625" 

8.071" 

41.063 

0.283 

80-2,500 

Std. Wt., Sch 40 

8.625" 

7.981" 

40.086 

0.281 

80-2,500 

Sch 60 

8.625" 

7.813" 

38.288 

0.279 

80-2,500 

Extra Strong, Sch 80 

8.625" 

7.625" 

36.315 

0.276 

80-2,500 

PVC Class 125 

8.625" 

8.095" 

41.324 

0.283 

80-2,500 

PVC Class 160 

8.625" 

7.961" 

39.869 

0.281 

80-2,500 

PVC Class 200 

8.625" 

7.805" 

38.203 

0.279 

80-2,500 

10" Sch 10S 

10.75" 

10.420" 

70.195 

0.321 

125-4,000 

Sch 20 

10.75" 

10.250" 

67.668 

0.318 

125-4,000 

Sch 30 

10.75" 

10.136" 

66.069 

0.316 

125-4,000 

Sch 40, Std.Wt. 

10.75" 

10.020" 

64.532 

0.314 

125-4,000 

Extra Strong, Sch 60 

10.75" 

9.750" 

61.016 

0.309 

125-4,000 

Sch 80 

10.75" 

9.564" 

58.644 

0.306 

125-4,000 

PVC Class 125 

10.75" 

10.088" 

65.431 

0.315 

125-4,000 

PVC Class 160 

10.75" 

9.924" 

63.272 

0.312 

125-4,000 

PVC Class 200 

10.75" 

9.728" 

60.733 

0.309 

125-4,000 

12" Sch 10S 

12.75" 

12.390" 

104.636 

0.367 

175-5,000 

Sch 20 

12.75" 

12.250" 

102.553 

0.364 

175-5,000 

Sch 30 

12.75" 

12.090" 

99.347 

0.36 

175-5,000 

Std. Wt., Sch 40S 

12.75" 

12.000" 

97.576 

0.358 

175-5,000 

Sch 40 

12.75" 

11.938" 

97.369 

0.356 

175-5,000 

Sch 60 

12.75" 

11.625" 

90.441 

0.348 

175-5,000 

Extra Strong 

12.75" 

11.750" 

92.775 

0.351 

175-5,000 

Sch 80 

12.74" 

11.376" 

85.922 

0.342 

175-5,000 

PVC Class 125 

12.75" 

11.966" 

96.912 

0.357 

175-5,000 

PVC Class 160 

12.75" 

11.770" 

93.152 

0.352 

175-5,000 

PVC Class 200 

12.75" 

11.538" 

88.842 

0.346 

175-5,000 

 

Continued on Next Page

 

Summary of Contents for FS200B

Page 1: ...wept impeller shape provides higher more constant torque than other impeller designs and is less prone to fouling by water borne debris The forward curved shape coupled with the absence of magnetic dr...

Page 2: ...nics package inserted into a proprietary cast bronze pipe tee with threaded NPT female iron pipe thread FIPT connections They are available in the following sizes and thread types Model Thread Size FS...

Page 3: ...ertical pipes 3 Small pipe PVC and Bronze Tee Type sensors are Factory Set but for insert sensors the Insertion depth should be set to 1 1 2 for accurate flow readings The following pages show methods...

Page 4: ...tlet tee the inside dimension of the tee is not the same as the pipe O D Install the 2 NPT adapter provided using a thread sealant to prevent leakage Tighten as necessary Rain Bird insert style sensor...

Page 5: ...n data transmission to connect the sensor to the transmitter monitor or controller 3 Make a water tight splice Direct burial silicone grease splices are recommended Rain Bird DBRY20 or 3M DBR Y 6 Two...

Page 6: ...000 5 4 to 54 20 to 200 1 2 to 12 FS075P 3 4 PVC Tee Flow Sensor 0 1563 0 9000 3 3 to 33 13 to 125 75 to 7 5 FS050P 1 2 PVC Tee Flow Sensor 0 0780 0 9000 1 9 to 19 7 to 70 43 to 4 3 Description of Col...

Page 7: ...80 2 500 Sch 20 8 625 8 125 41 653 0 283 80 2 500 Sch 30 8 625 8 071 41 063 0 283 80 2 500 Std Wt Sch 40 8 625 7 981 40 086 0 281 80 2 500 Sch 60 8 625 7 813 38 288 0 279 80 2 500 Extra Strong Sch 80...

Page 8: ...h 30 20 00 19 000 239 666 0 547 400 12 000 Sch 80 20 00 17 938 213 14 0 511 400 12 000 22 Std Wt Sch 20 22 00 21 25 301 975 0 621 500 15 000 Extra Strong Sch 30 22 00 21 00 294 642 0 616 500 15 000 Sc...

Page 9: ...necessary 7 Refer to Figure 3 To reinstall position the impeller in the cavity oriented as in Step 4 so that the impeller blades point into the flow direction and toward the small alignment hole locat...

Page 10: ...7 VDC in a No Flow situation or less than 3 VDC in a flow situation disconnect the sensor from the barrier strip and measure the voltage at the sensor input terminals of the barrier strip again It sh...

Page 11: ...r recommended design flow range for FS100B Linearity 0 2 of full scale over recommended design flow range 0 7 of full scale over recommended design flow range for FS100B Transducer Excitation Typicall...

Reviews: