background image

 RailKing Scale F40PH Diesel Engine

19  

Cab Chatter

Lock-out

Volume

Battery

FYS

Remedy

Remedy

Remedy

Remedy

Remedy

Sometimes the Cab Chatter sounds 
don’t play.

I can’t get the engine to run after I 
power up the transformer. It sits still 
with the engine sounds running.

The engine won’t lock into forward, 
neutral, or reverse.

The sounds seem distorted, especially 
when the whistle or bell is activated.

The engine will not leave the initial 
neutral setting.

The FYS sounds occasionally repeat 
themselves.

I get no sounds when the engine shifts 
between directions.

After I turn off my transformer, my 
engine continues to make sounds 
before quitting.

Cab Chatter plays only in neutral at 
random intervals.

The engine is locked into the neutral 
position. Follow the procedure in the 
“Lock into a Direction” section.

Engine speed must be below 10 scale 
mph (approx. 10 volts or less in 
conventional mode).

Proto-Sound 2.0 volume is set too 
high. Turn the volume control knob on 
the bottom of the chassis counter-
clockwise to reduce the volume.

Check to be sure the battery is 
installed and fully charged. See the 
“Self-Charging Battery Back-Up” 
section.

The battery may be dead or need to 
be charged. See the “Self-Charging 
Battery Back-Up” section.

Proto-Sound 2.0 is designed to 
continue to sound for a few seconds 
after power to the track has been shut 
off.

Proto-Sound 2.0 has a built-in random 
number generator that randomly 
selects each sound clip to play. 
Because there are a limited number of 
sound clips available in each FYS 
sequence, it is probable that some of 
these sound clips will be repeated 
from time to time.

Summary of Contents for F40-PH

Page 1: ...any traditional O 31 Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 21 for a complete list of...

Page 2: ...ng in damage to your layout This train set is intended for indoor use Do not use if water is present Serious injury or fatality may result l l l l Do not operate the hobby transformer with damaged cor...

Page 3: ...omotive was built several months before you set it up that the rechargeable battery has run down and needs to be charged before operating If you notice that the sounds are garbled test and charge the...

Page 4: ...speed The engine will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly...

Page 5: ...the volume of all sounds made by this engine turn the master volume control knob located next to the fuel tank clockwise to increase the volume and counter clockwise to decrease the volume Proto Soun...

Page 6: ...you should tap the buttons very quickly with a second pause between button presses You may need to practice your timing to make this work smoothly Proto Sound 2 0 Operating Instructions Timing Chart T...

Page 7: ...d 2 0 has disabled operator control over the Horn and Bell buttons until the full FYS sequence is complete After waiting about 30 seconds for that sequence to run press the Direction button again to t...

Page 8: ...ill not be active when you run FYS in Proto Sound 2 0 FYS can be triggered from Neutral It will operate the same as if triggered while in motion except that at the conclusion of the FYS the engine wil...

Page 9: ...le on the run Because the engine will run more slowly at a given throttle voltage when speed control is on than when it is off you should adjust the throttle to a lower power level for operation with...

Page 10: ...ell Direction Lock Two Horn Blasts Repeat to Return to Normal Condition indicates change is made To override the settings you currently have assigned to the engine and reset it to its factory defaults...

Page 11: ...gh the smokestack see Fig 2 We recommend M T H ProtoSmoke Seuthe LGB or LVTS fluids Do not overfill the unit or the fluid may leak out and coat the interior engine components If you choose not to add...

Page 12: ...heck the wick to see if it has become hard blackened and unabsorbent around the heating element Remove the smoke unit inspection cover from the smoke unit s body see Fig 4 After removing the chassis a...

Page 13: ...st Follow the greasing instructions below Note that in some tightly packed engines you may need to move internal components temporarily in order to access the gears 1 To access the gear box remove the...

Page 14: ...p which can cause poor electrical contact and traction and prematurely wear out the neoprene traction tires Wheels and tires can be cleaned using denatured not rubbing alcohol applied with a cotton sw...

Page 15: ...roove in the drive wheel using a razor blade or small flathead screwdriver to pry away any remains 2 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to s...

Page 16: ...self charging battery recharges continuously during train operation and should last for up to five years The battery is a dry battery that should not leak or cause any damage to your engine Depending...

Page 17: ...ully recharge if your engine has a smoke unit be sure it is turned off Use M T H s battery recharger sold separately that plugs into a wall outlet and a special port under the engine to recharge the b...

Page 18: ...e coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled When I press the whistle button the bell sounds Reverse the transformer leads...

Page 19: ...engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2...

Page 20: ...ealistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS is enabled This way the engine remains still at its stop as the operator cycles through the FYS sequences FYS is programme...

Page 21: ...andard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostl...

Page 22: ...Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including sound lights and smoke Proto Dispatch Operation Public Address like feature allow...

Page 23: ...rollers batteries smoke unit wicks and traction tires We will repair or replace at our option the defective part without charge for the parts or labor if the item is returned to an Authorized M T H Se...

Page 24: ...WARRICK CUSTOM HOBBIES PLANTATION 954 370 0708 info warrickcustomhobbies com www warrickcustomhobbies com FRANK S TRAINS HOBBIES INC OLDSMAR 813 855 1041 FTH allhobbies com www allhobbies com READY T...

Page 25: ...757 4246 mthdepot valstar net NASSAU HOBBY CENTER INC FREEPORT 516 378 9594 Charlienassau aol com KROSS HARDWARE WEST BABYLON 631 669 3069 t989 aol com CITY DEPOT INC NEW HAMPTON 845 374 3010 citydep...

Page 26: ...om TRAIN DEPOT M ANASSAS 703 335 2216 NORGE STATION WILLIAMSBURG 757 564 7623 norgetrains cs com NUTBUSH EXPRESS VICTORIA 804 696 1902 thenutbushexp meckcom net TOY TRAIN CENTER RICHMOND 804 288 4475...

Reviews: