background image

iR2623-S3 User Manual

9

3. E-Mail Notify

Configuring an e-mail address for notification of drive malfunctioning or being removed. 

3-1 Setup

1). Insert “Outgoing” SMTP and e-mail name and address.

2). If it is passwords required, select the option “SMTP Login Authentication” and insert the 

passwords. 

3). When the configuration completed, click on the “OK” button to save.

※ 

Device must be connected in operational states during configurations to take effects. 

3-2 HDD Fail / Device Removed

1). Insert the e-mail address of the receiver for notification and click on “+” to add the inserted 

e-mail address onto the notifying list. (Maximum up to 10 e-mail addresses)  

2). Insert the error message and descriptions from the columns of “Subject” and “Contents”. 

3). When the configuration completed, click on the “OK” button to save. 

※ 

Device must be connected in operational states during configurations to take effects. 

Summary of Contents for InTANK iR2623-S3

Page 1: ...iR2623 S3 User Manual InTANK ...

Page 2: ... InTANK iR2623 S3 User Manual 1 InTANK iR2623 S3 產品使用說明 12 iR2623 S3 User Manual V1 1 ...

Page 3: ...ion user manual update or firmware update please contact your local supplier or visit www raidon com tw for further information Copyright RAIDON TECHNOLOGY INC All rights reserved Open the package and you should find the following Please make sure that the contents listed above are not damaged or missing If you should find damages or missing contents please contact your supplier immediately 1 Pack...

Page 4: ...ail LED Pri HDD status indicator Sec HDD status indicator Pri HDD tray access light Sec HDD tray access light Power On Orange light always on Blue and Purple light flashing Blue light always on Stabdby Orange light always on Blue light always on Blue light always on HDD Failure Red light always on Red light always on Blue light always on On Access Orange light always on Blue and Purple light flash...

Page 5: ...onsible for any lost of data caused during the use of the unit or the recovery of the data lost Please follow the instructions below to complete the hardware installation Open the package and take out the product making sure that all the enclosed contents are not damaged or missing Should you find damages or missing contents please contact your supplier immediately Place the system on a stable sur...

Page 6: ...lection RAID 0 mode by setting the jumper on the bottom of the two pins RAID 1 mode by setting the jumper on the top of the two pins 1 RAID 1 Mode 1 Place two new hard drives into IR2623 S3 and strongly suggest you to use two identical hard drives to get the equal capacity If the capacity is different IR2623 S3 is downward to the small hard drive capacity 2 Under RAID 1 mode two hard drives has th...

Page 7: ...formation 1 In IR2623 S3 the installed hard drive can be detected by the Device Manager of Computer Management for Windows 2 Customers can choose to format the hard drive by using the Disk Management tool of the operating system before using the IR2623 S3 At this point the installation process is completely finished The user can freely retrieve and save data to IR2623 S3 just like retrieving and s...

Page 8: ...drive is normal RAID 1 degraded Pri X Sec O 5 RAID 1 Failure Primary and secondary hard drives are failure RAID 1 failure Pri X Sec X 6 RAID 1 Failure Double Source RAID 1 failure Double Source 7 RAID 0 Failure Primary hard drive is missing but secondary hard drive is normal RAID 0 failure Pri M Sec O 8 Rebuilding Rebuilding Sec Pri 32 1 Booting and Normal status IR2623 RAID 1 vxxxxxx x Pri HDD OK...

Page 9: ...he system is still in operation without shutting down the machine If the failed hard drive is replaced shortly the system will automatically execute the Auto Rebuilding function without affecting the system operation and without any operation command from the user When the IR2623 S3 detects a hard drive missing or a hard drive failure the Buzzer will start and the LCD display screen will display t...

Page 10: ...veals relative information accordingly 2 Firmware Upgrade You may update the Firmware via this GUI simply click on Load button to locate the firmware file to proceed After update is finished you may restart the power properly to operate with newly updated firmware Caution Any random firmware updates may cause device in malfunction it is strongly suggested not to update device firmware if device is...

Page 11: ...e OK button to save Device must be connected in operational states during configurations to take effects 3 2 HDD Fail Device Removed 1 Insert the e mail address of the receiver for notification and click on to add the inserted e mail address onto the notifying list Maximum up to 10 e mail addresses 2 Insert the error message and descriptions from the columns of Subject and Contents 3 When the conf...

Page 12: ...iR2623 S3 User Manual 10 5 About Indicates GUI Management Software version 4 S M A R T ...

Page 13: ...an normal system down time Under the mirror mode RAID 1 what will be the system s total storage capacity when adding a brand new hard drive 1 The total storage capacity for IR2623 S3 is determined by the storage capacity of the primary hard drive installed during the initial usage 2 The storage capacity will not increase after initial installation even when place a brand new hard drive with larger...

Page 14: ...w raidon com tw 網站查詢 本公司將不另 通知 若您想獲得 RAIDON 最新產品訊息 使用手冊 韌體或對 RAIDON 產品有任何疑問 請您聯絡當地 供應商或到 www raidon com tw 取得相關訊息 本手冊相關產品內容歸 銳銨科技股份有限公司 版權所有 打開包裝外盒後 包裝內容應包含下列組件 請確認相關配件與產品本身是否有受損或配件缺少 若有任何疑問請與本產品供應商聯絡 1 產品外觀及包裝內容 2 環境需求 3 硬體需求與注意事項 4 硬體安裝 5 設定 RAID 層級 6 電腦安裝 7 LCD 訊息顯示 8 資料重建功能說明 9 GUI 功能說明與韌體更新 10 常見問題 IR2623 S3 IR2623 S3 產品本體 X1 內含抽取盒 x3 內接 RS232 線 x1 外接 RS232 線 x1 SATA 線 x2 光碟 x 1 螺絲及鑰匙 x 3 快速安...

Page 15: ... 散熱風扇 14 RAID 模式設定 15 RS232 埠 16 3 5 硬碟 SATA 連接埠 17 SATA 15Pin 電源輸入埠 18 4Pin 電源輸入埠 19 2 5 硬碟 SATA 連接埠 狀態 面板燈號 3 5 硬碟讀取燈 2 5 硬碟 讀取燈 蜂鳴器 故障顯示燈 主硬碟 狀態指示燈 次硬碟 狀態指示燈 主硬碟 讀取燈 次硬碟 讀取燈 開機 橘燈恆亮 藍紫燈閃爍 藍燈恆亮 待機 橘燈恆亮 藍燈恆亮 藍燈恆亮 硬碟故障 RAID降級 紅燈恆亮 紅燈恆亮 藍燈恆亮 鳴叫 資料存取 橘燈恆亮 藍紫燈閃爍 藍燈閃爍 資料重建 Source 橘燈恆亮 藍燈恆亮 藍燈恆亮 資料重建 Target 紅燈閃爍 藍燈恆亮 風扇故障 紅燈恆亮 橘燈恆亮 藍燈恆亮 藍燈恆亮 鳴叫 溫度過高 紅燈恆亮 橘燈恆亮 藍燈恆亮 藍燈恆亮 鳴叫 ...

Page 16: ...他問題 以免導致系統損毀或資料遺失 6 硬碟格式化後 iR2623 S3 的總使用儲存容量或許會與硬碟容量加總後的有所不同 7 強烈建議除了使用 iR2623 S3 系列的資料儲存功能外 請針對重要資料備份到另一個儲存裝置上或 遠端備份 雙重備援您重要的資料 若您儲存在 iR2623 S3 系列的資料損毀或遺失 RAIDON 將 不負任何的責任 請參照以下步驟完成硬體安裝 拆開外包裝並取出產品本體 將系統擺放於穩固平台 並確認散熱風扇口沒有被其他物體擋住 系統四周有適當的散熱空 間 擺放環境請避免接近潮濕或其他易對產品造成損傷的環境 請使用零件包內附的頂針插入鑰匙孔後 抽取盒門閂將會輕彈開啟 即可將硬碟抽取盒取出 將硬碟安裝到抽取盒上 並以零件包內附的螺絲加以固定 以避免不必要的移動對硬碟造成 傷害 硬碟安裝完成後請將抽取盒平移放入主機內並關上把手 將附件中的連接線分別接到電腦與 iR26...

Page 17: ...生問題 請確保系統的電源供應是穩定且獨立的 5 設定 RAID 層級 請透過機器後面的 jumper 來設定 RAID 層級 出廠預設值是 RAID 1 機器背面有三根 pin 腳用來設 定 RAID 層級 若要設定 RAID 0 模式 請選用下面兩根 若要設定 RAID 1 模式 請選用上面兩根 1 RAID 1 模式 1 將新的硬碟放入 iR2623 S3 中 強烈建議您使用兩顆相同的硬碟 以便取得對等的容量 如果兩 顆硬碟的容量不同 iR2623 S3 將會以小容量的硬碟為依據 2 RAID 1 模式下 兩顆硬碟是鏡射關係因此擁有相同的資料 因此有一顆硬碟損毀仍然可以正常 運作 當放入新硬碟取代損毀硬碟後 系統會自動將資料重建到新的硬碟 2 RAID 0 模式 1 將新的硬碟放入 iR2623 S3 中 強烈建議您使用兩顆相同的硬碟 以便取得對等的容量 如果兩 顆硬碟的容量不同 iR...

Page 18: ...iR2623 S3 的硬體安裝完成 即可準備進 開機動作 硬體安裝完成後 將 BIOS 的硬碟偵測設定為自動 iR2623 S3 將會被視為如同一顆硬碟一般 當電腦開機後 系統會顯示下列偵測訊息 1 安裝在 iR2623 S3 中的硬碟能夠被 Windows 的裝置管理員偵測到 2 使用 iR2623 S3 前 使用者可以透過磁碟管理選擇硬碟的格式 到此完成整個安裝程序 使用者可以如同存取一般硬碟般的使用 iR2623 S3 如果使用上仍有問題 請參閱附件的 Q A ...

Page 19: ...碟損毀而 Sec 硬碟仍然可正常存取 RAID 1 degraded Pri X Sec O 5 RAID 1 損毀 Pri 與 Sec 硬碟皆損毀 RAID 1 failure Pri X Sec X 6 RAID 1 損毀 Source 碟重複 RAID 1 failure Double Source 7 RAID 0 損毀 Pri 或 Sec 硬碟遺失 9 資料重建 Rebuilding Sec Pri 32 1 開機與正常待機狀態 IR2623 RAID 1 vxxxxxx x Pri HDD OK Sec HDD OK RAID 0 failure Pri M Sec O RAID 0 failure Pri O Sec M ...

Page 20: ...LCD 顯示幕與監控軟體發出警示 使用者可以在 系統仍在運作下 無需關掉機機器即可將損毀的硬碟取出 一但替換損毀硬碟後 IR2623 S3 即會在 不影響系統運作的情況下自動開始進 資料重建 使用者也無需對 IR2623 S3 下任何指令 當 IR2623 S3 偵測到硬碟遺失或是損毀 蜂鳴器會啟動 LCD 螢幕會顯示以下訊息 當移除損毀的硬碟並替換一顆新硬碟後 如果新硬碟有正確安裝 LCD 螢幕會顯示以下訊息 安裝新硬碟後幾秒鐘 LCD 螢幕會顯示資料重建的進度 當資料重建完成後 LCD 螢幕會顯示以下訊息 8 資料重建功能說明 Pri HDD OK Sec HDD OK T RAID 1 degraded Pri X Sec O Pri HDD OK Sec HDD Insert Rebuilding Sec Pri 32 Pri HDD Insert Sec HDD OK Rebui...

Page 21: ...安裝 GUI 軟體 藉此監控 IR2623 S3 的狀態 HDD1 等於 Pri 硬碟 HDD2 等於 Sec 硬碟 1 系統狀態 GUI 會自動偵測 IR2623 S3 並且顯示相關資訊 2 韌體升級 使用者可以透過此 GUI 進 韌體升級 只需簡單的點選 Load 指定韌體檔案位置後即可進 升級 升級過程或許需要重新啟動系統來完成整個升級程序 注意 任意更新韌體有可能導致系統運作不正常 強烈建議如果系統運作正常情況下不要進 韌體升級 9 GUI 功能說明與韌體更新 ...

Page 22: ... e mail 相關名稱與完整位置 以及 SMTP 的相關資訊 2 如果需要密碼 請勾選 SMTP Login Authentication 並輸入密碼 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 3 2 硬碟損毀 裝置被移除 1 在 E Mail Address 欄位填入要收取通知的 e mail 點選 即可增加另一組 最多可填 入 10 組 e mail 2 在 Subject 與 Contents 填入 e mail 訊息的主旨與內容 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 ...

Page 23: ...iR2623 S3 User Manual 21 5 關於 GUI 軟體版本 4 S M A R T ...

Page 24: ...系統不穩定 硬碟損毀 Q1 A Q2 A 安裝完 IR2623 S3 後 電腦無法開機或是電腦認不到 IR2623 S3 1 請確認 IR2623 S3 上的 LCD 螢幕顯示正常 2 請確認 SATA 線有正確的跟電腦連接且硬碟是可正常運作 3 如果一切正常但使用者還是無法正常開機 這有可能是因為硬體上的相容性問題 如果是硬體 上相容性問題 請連繫我們的客服部門 使用時 電腦運作正常但是 IR2623 S3 的存取效能不正常 請確認 IR2623 S3 是否正在資料重建 1 請確認所使用的連接線長度 是否所使用的 SATA 線太長以及是否合乎標準規範 2 如果線材的長度與規格都沒問題 請關閉 IR2623 S3 並取出其中的硬碟 直接接硬碟連接到 電腦並進 檢測 有可能是硬碟中的壞軌導致 RAID 1 模式下 如果放入一顆新的硬碟 系統的總容量會是 1 IR2623 S3 的總容量是依據...

Page 25: ...iR2623 S3 User Manual 23 www raidon com tw ...

Reviews: