background image

 

 

 

 

 

InTANK 

iR2622 

User Manual 

Your Data Security Guardian 

Summary of Contents for intank ir2622

Page 1: ...InTANK iR2622 User Manual Your Data Security Guardian ...

Page 2: ...iR2622 User Manual 2 InTANK iR2622 User Manual 3 InTANK iR2622 產品使 用說明 14 ...

Page 3: ... your local supplier or visit www raidon com tw for further information Copyright RAIDON TECHNOLOGY INC All rights reserved 1 Package Contents and Product Views 2 Operating Information 3 Hardware Requirements and Precautions 4 Hardware Installation Procedure 5 Setting RAID Mode 6 Computer Set Up 7 Hard Disk status on LCD screen 8 Data Rebuilding Operation 9 GUI Monitoring Software and Firmware Upd...

Page 4: ...de switch 11 RS232 Port 12 SATA Port 13 15 PIN Power Connector 14 4Pin Power Connector LED Indicators Status Fail LED HDD 1 HDD 2 TRAY 1 TRAY 2 Buzzer Stand by Orange light on Blue light on HDD Failure Red light on Red light on On Access Orange light on Blue and Purple blinking Rebuilding Source Orange light on Blue light on Rebuilding Target Red blinking Fan Failure Red light on On Over Heat 50 C...

Page 5: ...e follow the instructions below to complete the hardware installation Step 1 Open the package and take out the product making sure that all the enclosed contents are not damaged or missing Should you find damages or missing contents please contact your supplier immediately Step 2 Place the system on a stable surface Ensure that it is well ventilated without blockage to the vent and kept away from ...

Page 6: ... drives into iR2622 and strongly suggest you to use two identical hard drives to get the equal capacity If the capacity is different iR2622 is downward to the small hard drive capacity 2 Under RAID 1 mode two hard drives has the identical information as one to mirror to the other one therefore each of the hard drive failed is still able to function normally When you replace the failed hard disk to...

Page 7: ...2 the installed hard drive can be detected by the Device Manager of Computer Management for Windows 2 Customers can choose to format the hard drive by using the Disk Management tool of the operating system before using the iR2622 At this point the installation process is completely finished The user can freely retrieve and save data to iR2622 just like retrieving and saving data to a regular hard ...

Page 8: ...ard drives are failure 6 RAID 1 Failure Double Source 7 RAID 0 Failure Primary hard drive is missing but secondary hard drive is normal 8 Rebuilding 7 Hard Disk status on LCD screen Pri HDD OK Sec HDD OK T Pri HDD OK F Sec HDD OK RAID 1 degraded Pri X Sec O RAID 1 failure Pri X Sec X RAID 1 failure Double Source RAID 0 failure Pri M Sec O Rebuilding Sec Pri 32 8 iR2622 RAID 1 vxxxxxx x Pri HDD OK ...

Page 9: ...em is still in operation without shutting down the machine If the failed hard drive is replaced shortly the system will automatically execute the Auto Rebuilding function without affecting the system operation and without any operation command from the user When the iR2622 detects a hard drive missing or a hard drive failure the Buzzer will start and the LCD display screen will display the followi...

Page 10: ...elative information accordingly 2 Firmware Upgrade You may update the Firmware via this GUI simply click on Load button to locate the firmware file to proceed After update is finished you may restart the power properly to operate with newly updated firmware Caution Any random firmware updates may cause device in malfunction it is strongly suggested not to update device firmware if device is operat...

Page 11: ... button to save Device must be connected in operational states during configurations to take effects 3 2 HDD Fail Device Removed 1 Insert the e mail address of the receiver for notification and click on to add the inserted e mail address onto the notifying list Maximum up to 10 e mail addresses 2 Insert the error message and descriptions from the columns of Subject and Contents 3 When the configur...

Page 12: ... check whether the iR2622 is in the progress of executing data auto rebuild 1 Please examine if the length of the connection cables SATA cable that connect the drives to the computer system is too long and whether the specification these cables complies with the requirements 2 If both the lengths and specification of the cables are checked out ok please turn off iR2622 and remove the hard drive fr...

Page 13: ...troller will remember when completion percentage of the auto rebuilding process and resume the rebuilding process when the power is back on Q2 Is it possible to lose any part of the data during the data auto rebuilding A The data auto rebuilding function will copy data from one sector to another sector Technically speaking the data will not be lost during the auto rebuilding process However if the...

Page 14: ...想獲得RAIDON 最新產品訊息 使 用 手冊 韌體或對RAIDON 產品有任何疑問 請您聯絡當地 供應商或到www raidon com tw 取得相關訊息 本 手冊相關產品內容歸 銳銨科技股份有限公司 版權所有 1 產品外觀及包裝內容 2 環境需求 3 硬體需求與注意事項 4 硬體安裝 5 設定RAID層級 6 電腦安裝 7 LCD訊息顯 示 8 資料重建功能說明 9 GUI功能說明與韌體更新 10 常 見問題 打開包裝外盒後 包裝內容應包含下列組件 請確認相關配件與產品本 身是否有受損或配件缺少 若有任何疑問請與本產品供應商聯絡 關於這份 手冊 目錄索引 1 產品外觀及包裝內容 iR2622 iR2622產品本體X1 內含抽取盒x2 內接RS232線 x1 外接RS232線 x1 SATA線 x1 光碟 x1 零件包 x2 快速安裝導引 x 1 14 ...

Page 15: ...n電源輸 入埠 14 4Pin電源輸 入埠 燈號 一覽表 工作溫度 0 40 C 32 104 F 儲存溫度 10 70 C 14 158 F 工作電壓 100 240V AC 1 電腦或伺服器具備SATA I SATA II或SATA III介 面 2 具備SATA I SATA II或SATA III介 面的硬碟 3 強烈建議使 用iR2622前先設定好RAID模式 預設值是RAID 1 狀態 警 示燈 HDD 1 HDD 2 TRAY 1 TRAY 2 蜂鳴器 待機 橘燈恆亮 藍燈恆亮 硬碟故障 紅燈恆亮 紅燈恆亮 鳴叫 資料存取 橘燈恆亮 藍紫燈閃爍 資料重建 Source 橘燈恆亮 藍燈恆亮 資料重建 Target 紅燈閃爍 風扇故障 紅燈恆亮 鳴叫 溫度過 高 50 C 紅燈恆亮 鳴叫 2 環境需求 3 硬體需求與注意事項 15 ...

Page 16: ...擋住 系統四周有適當的散熱空 間 擺放環境請避免接近潮濕或其他易對產品造成損傷的環境 步驟 3 請使 用零件包內附的鑰匙插 入鑰匙孔向左轉90度 輕按鎖頭抽取盒 門閂將會輕彈開啟 即可將 硬碟抽取盒取出 步驟 4 將硬碟安裝到抽取盒上 並以零件包內附的螺絲加以固定 以避免不必要的移動對硬碟造成傷 害 步驟 5 硬碟安裝完成後請將抽取盒平移放 入主機內並關上把 手 步驟 6 將附件中的連接線分別接到電腦與iR2622的相關連接埠 參照以下圖 面 Note 1 RS232埠與RS232線 提供 工控系統或是 工業電腦透過RS232監控硬碟狀態 2 我們不建議使 用者在未經授權的情況下 自 行拆卸系統 如未經授權 自 行拆卸所導致的損毀將不在保固之列 3 為了防 止系統發 生問題 請確保系統的電源供應是穩定且獨 立的 注意 一旦使 用模式確認後 使 用相同的硬碟進 行模式切換將會導致資料遺失 如...

Page 17: ...因此擁有相同的資料 因此有 一顆硬碟損毀仍然可以正常 運作 當放 入新硬碟取代損毀硬碟後 系統會 自動將資料重建到新的硬碟 2 RAID 0 模式 1 將新的硬碟放 入iR2622中 強烈建議您使 用兩顆相同的硬碟 以便取得對等的容量 如果兩顆 硬碟的容量不同 iR2622將會以 小容量的硬碟為依據 2 RAID 0模式下 兩顆硬碟的容量會被加總成 一個 大儲存容量 並且提供更佳的存取效能 當iR2622的硬體安裝完成 即可準備進 行開機動作 硬體安裝完成後 將BIOS的硬碟偵測設定為 自動 iR2622將會被視為如同 一顆硬碟 一般 當電腦開 機後 系統會顯 示下列偵測訊息 1 安裝在iR2622中的硬碟能夠被Windows的裝置管理員偵測到 2 使 用iR2622前 使 用者可以透過磁碟管理選擇硬碟的格式 到此完成整個安裝程序 使 用者可以如同存取 一般硬碟般的使 用iR2622 如果...

Page 18: ...碟皆損毀 6 RAID 1損毀 Source碟重複 7 RAID 0損毀 Pri硬碟遺失 而Sec硬碟仍然正常 8 資料重建 7 訊息顯 示 Pri HDD OK Sec HDD OK T Pri HDD OK F Sec HDD OK RAID 1 degraded Pri X Sec O RAID 1 failure Pri X Sec X RAID 1 failure Double Source RAID 0 failure Pri M Sec O Rebuilding Sec Pri 32 18 iR2622 RAID 1 vxxxxxx x Pri HDD OK Sec HDD OK ...

Page 19: ...D顯 示幕與監控軟體發出警 示 使 用者可以在系統仍 在運作下 無需關掉機機器即可將損毀的硬碟取出 一但替換損毀硬碟後 iR2622即會在不影響系統 運作的情況下 自動開始進 行資料重建 使 用者也無需對iR2622下任何指令 當iR2622偵測到硬碟遺失或是損毀 蜂鳴器會啟動 LCD螢幕會顯 示以下訊息 當移除損毀的硬碟並替換 一顆新硬碟後 如果新硬碟有正確安裝 LCD螢幕會顯 示以下訊息 安裝新硬碟後幾秒鐘 LCD螢幕會顯 示資料重建的進度 當資料重建完成後 LCD螢幕會顯 示以下訊息 RAID 1 degraded Pri X Sec O Pri HDD OK Sec HDD Insert Pri HDD Insert Sec HDD OK Rebuilding Sec Pri 32 Rebuilding Pri Sec 32 Pri HDD OK Sec HDD OK 19 8 資...

Page 20: ...過光碟來安裝GUI軟體 藉此監控iR2622的狀態 HDD1等於Pri硬碟 HDD2等於Sec硬碟 1 系統狀態 GUI會 自動偵測iR2622並且顯 示相關資訊 2 韌體升級 使 用者可以透過此GUI進 行韌體升級 只需簡單的點選 Load 指定韌體檔案位置後即可進 行升級 升級過程或許需要重新啟動系統來完成整個升級程序 注意 任意更新韌體有可能導致系統運作不正常 強烈建議如果系統運作正常情況下不要進 行韌體升級 9 GUI功能說明與韌體更新 20 ...

Page 21: ...mail相關名稱與完整位置 以及SMTP的相關資訊 2 如果需要密碼 請勾選 SMTP Login Authentication 並輸 入密碼 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 3 2 硬碟損毀 裝置被移除 1 在E Mail Address欄位填 入要收取通知的e mail 點選 即可增加另 一組 最多可填 入10 組e mail 2 在 Subject 與 Contents 填 入e mail訊息的主旨與內容 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 21 ...

Page 22: ...正常 A 請確認iR2622是否正在資料重建 1 請確認所使 用的連接線 長度 是否所使 用的SATA線太 長以及是否合乎標準規範 2 如果線材的 長度與規格都沒問題 請關閉iR2622並取出其中的硬碟 直接接硬碟連接到電 腦並進 行檢測 有可能是硬碟中的壞軌導致 硬碟損毀 Q1 RAID 1模式下 如果放 入 一顆新的硬碟 系統的總容量會是 A 1 iR2622的總容量是依據 一開始安裝的主硬碟容量 而定 2 安裝完成後 即使更換 一顆較 大容量的硬碟 儲存容量也不會增加 Q2 為何當我安裝第 二顆硬碟時出現錯誤訊息 A 1 第 二顆硬碟的容量必須 大於第 一顆硬碟 否則iR2622不會進 行資料重建 關於資料 自動重建功能 Q1 如果當iR2622在資料重建時關掉電腦電源 會不會怎樣 A 在RAID 1模式下 資料重建過程中關閉電源 控制器會 自動記憶已完成的百分 比 當在度開 啟電源...

Page 23: ...iR2622 User Manual Q2 資料重建過程中是否有可能會遺失資料 A 資料重建功能是Sector to Sector的拷 貝 方式 技術上來說 資料並不會在資料重建過程中遺 失 但是 如果資料重建過程中 原本的硬碟 Source 被偵測到壞軌 iR2622將會採 用模擬 方式 而不會因此壞軌認為硬碟損毀 因此 這種情況下儲存在壞軌的資料就有可能會遺失 23 ...

Page 24: ...www raidon com tw Your Data Security Guardian ...