Make sure that all appliances are in good working order before connecting them to the
generator. If an appliance starts to malfunction, becomes sluggish, or stops suddenly,
immediately switch off the engine generator circuit breaker.
3. For best effect and extend the life of the generator, the new generator should normally run
20 hours under 50% load.
EXIT & OVERLOAD
■ If the generator is overloaded (above maximum) or if there is a break in the connected
device, the connected device must be switched off immediately.
■ Turn off the engine if the overload indicator comes on and check the overload source.
■ Before connecting the appliance to the generator, check that it is in good condition and that
its electrical power does not exceed that of the generator. Then connect the power cord of the
appliance and start the engine.
Oil indicator
■ The oil indicator is designed to prevent engine damage caused by insufficient oil in the
crankcase. Before the oil level in the crankcase falls below the hazardous limit, the oil indicator
starts to illuminate automatically and the engine will stop (the engine switch will remain in the
“ON” position).
■ If the low oil alarm system switches off the engine, the oil indicator (red) will come on. If this
happens, add engine oil.
6. STOPPING THE ENGINE
To stop the engine in an emergency, turn the engine switch to the “OFF” position.
IN NORMAL USE:
1. Switch off the connected equipment and pull the inserted plug out.
2. Turn the engine switch to the “OFF” position
3. Turn the fuel cap lever fully clockwise to the “OFF” position. Turn the fuel cock to the “OFF
“ position.