background image

Verschlusstechnik

RAHRBACH

13

00

 - 

16

00

 m

m

Position “closed”

frame

Mounting Instruction for Pin Locking Mechanisms

1.Pin locking mechanisms in locked condition prevent the sliding door from being

shifted open from outside. From inside, the sliding door can always be opened

after actuating the emergency opening mechanism. The distance between door

and frame must be 20 mm min, and 35 mm max. (sealing thickness).

Series 7150

Follow Technical Data Sheet and Instructions

2. For this purpose, the pin locking mechanism is installed

in a convenient height adjacent to the rear panel of the

door. Borehole diameter 60 mm

Position “open”

frame

door

door

door sliding direction

door sliding direction

door sliding direction

Summary of Contents for 7150 Series

Page 1: ...utes electrically operated sliding doors except for Rahr bach product series 7150 with Reed Switch and in the area of vehicle container design and construction is currently in validation of RAHRBACH t...

Page 2: ...ction of locking position optional with reed relais 8 materials housing plastic bolt plastic nuts plastic button plastic profil cylinder brass screws stainless steel sealing rubber sealing grease unis...

Page 3: ...always be opened after actuating the emergency opening mechanism The distance between door and frame must be 20 mm min and 35 mm max sealing thickness Series 7150 Follow Technical Data Sheet and Instr...

Page 4: ...he outer side file a recess of 10 mm height and approx 3 mm width into the sheet in 3 o clock position to accept the little plate on the housing see arrow as a torsion safety mechanism Do not remove a...

Page 5: ...inside 6 Mark three holes of nuts on the door centre punch and drill 3mm holes Insert 3 9 mm plate screws sup plied as a fixation of the nut thereby the pin locking mechanism is secured against disass...

Page 6: ...ate it anti clockwise by about 180 1 Now the pin can be pushed inside 2 turn the key into vertical position again and take it out So the door is safeguarded against inad vertent opening Do not turn th...

Page 7: ...o disassemble M5 threaded pin exchange cylinder e g towards cylinder out of a master key system retain cylinder again with threaded pin Regarding the door thickness use the optional 5mm spa cer for in...

Page 8: ...chlusstechnik RAHRBACH Mounting Instruction for Pin Locking Mechanisms Series 7150 Follow Technical Data Sheet and Instructions Connect Reed Relais as shown in the datasheet Optional Reed relais funct...

Reviews: